SurgeX SX-20NE-RT

Manual do Usuário do Condicionador de Energia com Supressor de Surtos de Grau Industrial SurgeX SX20 NE/RT

1. Introdução

This manual provides detailed instructions for the installation, operation, and maintenance of the SurgeX SX20 NE/RT Industrial Grade Surge Suppressor Power Conditioner. The SX20 NE/RT is designed to protect sensitive electronic equipment from power surges and electrical disturbances, ensuring reliable performance and longevity of connected devices. Please read this manual thoroughly before installation and operation to ensure proper use and safety.

2. Informações de segurança

Adherence to the following safety precautions is essential to prevent injury and damage to the unit or connected equipment.

3. Produto acabadoview

The SurgeX SX20 NE/RT is a robust 20-amp surge suppressor and power conditioner housed in a magnetic shielding NEMA steel enclosure. It features True Series Mode technology for superior surge protection and EMI/RFI filtering. The unit also includes remote turn-on capabilities and a self-test circuit with visual indicators.

Principais características

Frente view of the SurgeX SX20 NE/RT surge suppressor and power conditioner, showing the brand logo, model number, indicator lights for REMOTE and SELF-TEST, and the A-1-1 certification.

Figure 1: SurgeX SX20 NE/RT Front Panel
This image displays the front panel of the SurgeX SX20 NE/RT unit. Visible elements include the SurgeX logo, 'True Series Mode' and 'Industrial Grade Surge Suppressor Power Conditioner' text, and the model number 'SX20 NE/RT'. Two indicator lights are present: a yellow 'REMOTE' light and a green 'SELF-TEST' light. A circular red-outlined opening is also visible on the lower right side of the front panel. The unit is housed in a grey metallic enclosure with multiple knock-outs on the top and right sides for wiring.

4. Configuração e instalação

The SurgeX SX20 NE/RT is designed for hardwired installation. Ensure all power is disconnected before proceeding.

4.1 Desembalagem

Carefully remove the unit from its packaging. Inspect for any signs of shipping damage. Report any damage to your supplier immediately.

4.2 Montagem

Mount the NEMA enclosure securely to a wall or suitable surface using appropriate fasteners. Ensure adequate ventilation around the unit.

4.3 Conexões de Fiação

The unit features a barrier strip accessible through knock-outs for hardwiring power input and output connections. Follow these steps:

  1. Select appropriate knock-outs for incoming and outgoing power cables.
  2. Route the 120V AC input power cable to the designated input terminals on the barrier strip.
  3. Route the output power cable(s) for the protected equipment to the designated output terminals.
  4. Ensure all connections are secure and properly torqued according to electrical code requirements.
  5. Verify correct polarity (Line, Neutral, Ground) for all connections.

4.4 Remote Turn-On Connection

The SX20 NE/RT supports remote turn-on and turn-off. A separate terminal block within the enclosure is provided for this functionality. Connect a contact closure or an applied DC voltage source to activate the remote control feature. Refer to the wiring diagram provided with the unit for specific terminal assignments.

5. Instruções de operação

Once installed and wired, the SurgeX SX20 NE/RT operates automatically to protect connected equipment.

5.1 Luzes indicadoras

O painel frontal possui duas luzes indicadoras:

5.2 Self-Test Function

The unit performs an automatic self-test upon power-up and continuously monitors its internal components. The green SELF-TEST indicator confirms proper operation. If this light is not illuminated, consult the troubleshooting section.

6. Manutenção

The SurgeX SX20 NE/RT requires minimal maintenance. Periodically inspect the unit and its connections for any signs of wear, damage, or loose wiring. Ensure the enclosure remains free of dust and debris. Do not use liquid cleaners directly on the unit. No internal user-serviceable parts are present.

7. Solução De Problemas

Consulte a tabela abaixo para obter informações sobre problemas comuns e suas possíveis soluções.

ProblemaPossível causaSolução
Equipamentos conectados sem energia.No input power; tripped circuit breaker; faulty wiring.Check main power supply; reset circuit breaker; verify all wiring connections.
SELF-TEST indicator is off.Internal fault; unit not receiving power.Verify input power. If power is present and light remains off, contact SurgeX support.
REMOTE indicator is on, but unit does not turn on/off.Incorrect remote control signal; faulty remote connection.Verify remote control wiring and signal type (contact closure or DC voltage)

8. Especificações

Detailed technical specifications for the SurgeX SX20 NE/RT.

RecursoEspecificação
Número do modeloSX-20NE-RT
Vol de entradatage120 Volts AC
Classificação de carga20 Amps
Tipo de gabineteMagnetic Shielding NEMA Steel Enclosure
Dimensões do produto (A x L x P)12.0 x 12.0 x 4.0 polegadas
Peso do item14.47 libras
Proteção contra surtosTrue Series Mode, withstands 1000 occurrences of surge pulse voltages up to 6000 volts
FiltragemFiltragem EMI/RFI
Controle remotoContact closure or applied DC voltage
FabricanteSurgeX
Data da primeira disponibilidade26 de julho de 2010

9. Garantia e Suporte

For information regarding the product warranty, please refer to the warranty card included with your SurgeX SX20 NE/RT or visit the official SurgeX website. For technical support, service, or replacement parts, please contact SurgeX customer service directly. Ensure you have your model number and purchase date available when contacting support.

Fabricante: SurgeX