1. Introdução
The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

Figura 1: Frente view of the APC Back-UPS BX1400UI.
2. Informações importantes de segurança
- Risco elétrico: Esta unidade contém alto volumetage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
- Conexão direta: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
- Ventilação: Assegure ventilação adequada ao redor do UPS. Não bloqueie as aberturas de ventilação.
- Odor inicial: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
- Substituição da bateria: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.
3. Conteúdo da embalagem
Verifique se seu pacote contém os seguintes itens:
- APC Back-UPS BX1400UI Unit
- Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
- Manual do usuário (este documento)
Observação: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically não incluso and must be purchased separately if needed.
4. Configuração
4.1. Unpacking and Battery Connection
- Retire cuidadosamente o UPS da embalagem.
- Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
- Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.
4.2. Conectando à energia
- Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
- Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
- Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.
4.3. Conexão de Equipamentos
The BX1400UI features six IEC 320 C13 outlets for connecting your devices.
- Tomadas com bateria de reserva e proteção contra surtos: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
- Proteção da linha de dados: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
- Interface USB: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.
5. Instruções de operação
5.1. Ligar / desligar
- Para ligar: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
- Para desligar: Pressione e mantenha pressionado o botão liga/desliga até que o UPS desligue.
5.2. Indicadores LED
The front panel features LED indicators to show the UPS status:
- On Line (Green LED): Indicates the UPS is operating on utility power and providing power to connected equipment.
- On Battery (Yellow LED): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
- Replace Battery (Red LED): Indicates the battery needs to be replaced.
- Overload (Red LED): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.
5.3. Vol automáticotage Regulamento (AVR)
O sistema UPS corrige automaticamente pequenas variações de tensão.tage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.
6. Principais características
- Tecnologia Line Interactive: Provides stable power by regulating voltage without constantly switching to battery.
- Vol Automáticotage Regulamento (AVR): Corrige pequenos volumestage flutuações sem usar a energia da bateria.
- Bateria de reserva: Supplies power to connected equipment during outage.
- Proteção contra surtos: Protects connected devices from damaging power surges and spikes.
- 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
- Interface USB: Enables communication with a computer for monitoring and controlled shutdown.
- Proteção da linha de dados: Safeguards telephone/DSL lines from surges.
7. Uso do software
The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.
7.1. APC PowerChute Personal Edition (Windows)
For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC website. Este software permite que você:
- Monitor UPS status, power consumption, and battery charge.
- Configure o desligamento automático do seu computador durante períodos prolongados de falta de energia.tage.
- Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
- Perform self-tests to ensure proper UPS functionality.
7.2. Linux Support (apcupsd / NUT)
For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.
8. Manutenção
8.1. Substituição da bateria
The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.
- During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
- After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
- Procedimento encerradoview (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.
8.2. Reinicialização do disjuntor
In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).
9. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| O nobreak não liga. | Battery connector disconnected; No input power. | Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet. |
| Initial strong odor. | New unit manufacturing residue. | This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks). |
| UPS emits a humming noise. | Operating on battery power; Normal electrical noise. | Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections. |
| 'Overload' LED is lit. | Equipamentos em excesso conectados. | Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel. |
| 'Replace Battery' LED is lit. | Bateria perto do fim da vida útil. | Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1. |
| Bateria com curta duração. | Bateria não totalmente carregada; Bateria perto do fim da vida útil; Carga excessiva. | Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old. |
For more detailed troubleshooting, refer to the complete user manual available on the APC website.
10. Especificações
| Recurso | Especificação |
|---|---|
| Modelo | BX1400UI |
| Capacidade (VA/Watts) | 1400 VA / 700 W |
| Vol de entradatage | 230 V CA |
| Frequência de entrada | 50 Hz |
| Volume de saídatage | 230V AC (simulated sine wave on battery) |
| Saídas de energia | 6 x IEC 320 C13 (Bateria de reserva e proteção contra surtos) |
| Classificação de proteção contra surtos | 273 Joules |
| Tipo de Bateria | Chumbo ácido selado |
| Configuração da bateria | 2 x 12 V 7.2 Ah |
| Tempo de recarga típico | 8 hours (to 90% capacity) |
| Runtime (at 700W load) | Aproximadamente 1 minuto |
| Runtime (at 100W load) | Aproximadamente 60 minutos |
| Dimensões (A x L x P) | 21.5 cm x 13 cm x 33.6 cm |
| Peso | 4.7 kg |
| Portas de Interface | USB Type B, RJ-11 (Data Line Protection) |

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.
11. Garantia e Suporte
11.1. Garantia do produto
The APC Back-UPS BX1400UI comes with a Garantia limitada de 2 ano A garantia é válida a partir da data da compra e cobre defeitos de materiais e de fabricação sob uso normal. Guarde o comprovante de compra para eventuais solicitações de garantia.
Importante: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.
11.2. Suporte Técnico
For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.