This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
Informações de segurança
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- Verifique o vol corretotage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- Assegure-se de que o aterramento esteja adequado, quando aplicável.
Produto acimaview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing e componentes internos.
Configuração e instalação
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- Desconexão de energia: Ensure all power to the circuit is completely disconnected before beginning installation.
- Montagem: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- Fiação: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

Figura 3: parte inferior view of the relay, showing the through-hole connector pins for wiring connections.
- Volumetage Verificação: Confirme se o volume de abastecimentotage for the coil matches the relay's specified voltage de 110-120V CA, 50/60Hz.

Figura 4: Close view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Verificação de carga: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

Figura 5: Lateral view of the relay, displaying detailed electrical ratings and certifications.
- Verificação final: Before restoring power, double-check all connections for security and correctness.
Instruções de operação
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltage alcance para operação confiável.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
Manutenção
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- Inspeção visual: Periodically check the relay for any signs of physical damage, discoloration, or loose connections.
- Limpeza: Se necessário, limpe cuidadosamente a parte externa do relé com um pano seco e macio. Não utilize solventes ou produtos de limpeza abrasivos.
- Inspeção de contato: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- Condições ambientais: Garanta que o ambiente operacional permaneça dentro das faixas de temperatura e umidade especificadas para evitar falhas prematuras.
Solução de problemas
Se o relé não estiver funcionando como esperado, considere os seguintes problemas comuns:
| Problema | Possível causa | Solução |
|---|---|---|
| Relay coil does not energize. | No power to coil, incorrect voltage, faulty wiring, or damaged coil. | Check power supply, verify voltage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| A carga não está recebendo energia. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
Especificações
| Parâmetro | Valor |
|---|---|
| Número do modelo | RH2B-UL-AC110-120V |
| Marca | Idec |
| Volume da bobinatage | 110-120V AC |
| Freqüência | 50/60 Hz |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| Classificação de potência | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| Tipo de montagem | Montagem em trilho DIN |
| Tipo de conector | Orifício passante |
| Modo de operação | Automático |
| Peso do item | 0.01 onças |
| Fabricante | Idec |
Garantia e Suporte
For warranty information and technical support, please contact Idec directly through their official website ou canais de atendimento ao cliente. Guarde o comprovante de compra para solicitações de garantia.
Idec Official Website: us.idec.com