Victron Energy CCH024016000

Victron Energy Centaur 24 Volts 16 Amp 3 Banco Carregador de Bateria

Model: CCH024016000

1. Introdução

This manual provides essential information for the safe and efficient operation of your Victron Energy Centaur 24-Volt 16 amp 3 Bank Battery Charger. The Centaur charger is designed for robust performance, featuring auto-ranging input and three isolated outputs for multi-battery setups. Please read this manual thoroughly before installation and use.

2. Informações de segurança

WARNING: Incorrect installation can be hazardous. Please consult a licensed professional and follow all applicable electrical codes during installation.

  • Ensure the charger is installed in a well-ventilated area.
  • Avoid exposing the charger to temperatures outside its operating range of -20 to 60°C (0 - 140°F).
  • Maintain humidity levels below 95% to prevent damage.
  • Não tente abrir ou consertar o carregador por conta própria. Encaminhe todos os serviços de manutenção a pessoal qualificado.
  • Desligue sempre a energia antes de fazer qualquer ligação ou realizar qualquer manutenção.

3. Principais características

  • Auto-Ranging Input: Covers 90-265VAC 50/60Hz, allowing use worldwide.
  • Three Isolated Outputs: Capable of simultaneously charging up to three battery banks, with each output supplying the full rated current.
  • Três-Stage Carregamento: Features bulk, absorption, and float stages with temperature compensation for optimal battery health.
  • Internal Temperature Sense: Ensures power components operate within specified limits, automatically reducing output current under extreme environmental conditions if necessary.
  • Construção robusta: Aluminium epoxy powder-coated cases with drip shield and stainless steel fixings provide durability in harsh environments, resisting heat, humidity, and salt air.
  • Proteção contra corrosão: Circuit boards are protected with an acrylic coating for maximum corrosion resistance.
Diagram illustrating key features of the Centaur battery charger, including full output power, three isolated outputs, three-stage charging, robust construction, and temperature sensors.

Figura 3.1: Overview of Centaur Charger Features

4. Especificações

EspecificaçãoValor
MarcaEnergia Victron
Número do modeloCCH024016000
Dimensões do produto (P x L x A)4.3" x 8.5" x 14" (110 mm x 214 mm x 351 mm)
Peso do item8.4 libras (3.8 kg)
Volume de saídatage24 Volts
Vol de entradatage90-265 VCA (50/60 Hz)
Classificação atual16 Amps
Número de saídas3
Tempo de carga da bateria4 Hours (absorption stage timer)
Temperatura de operação-20 to 60°C (0 - 140°F)
UmidadeMáx. 95% (sem condensação)
Diagram showing the dimensions of the Centaur battery charger: 110 mm (4.3 inches) deep, 214 mm (8.4 inches) wide, and 351 mm (13.8 inches) high.

Figure 4.1: Centaur Charger Dimensions

5. Configuração e instalação

Installation of the Centaur battery charger should only be performed by a qualified professional in accordance with all local and national electrical codes. Ensure proper ventilation and secure mounting of the unit.

The charger features three isolated outputs. Connect each output to a separate battery bank. The auto-ranging input allows connection to a wide range of AC power sources (90-265VAC, 50/60Hz) without manual adjustment.

Diagram showing the Centaur battery charger connected to three separate battery banks, illustrating its three isolated outputs.

Figure 5.1: Connecting to Multiple Battery Banks

6. Instruções de operação

The Centaur charger employs a sophisticated three-stage charging algorithm to optimize battery charging and prolong battery life:

  1. S a graneltage: The charger delivers maximum current to rapidly charge the battery until the output current reduces to 70% of the rated Amps.
  2. Absorção Stage: Uma vez que o volume stage criteria are met, a 4-hour timer begins. During this period, the charger maintains a constant voltage to ensure the battery is fully charged. An internal temperature sensor compensates the charge voltage to prevent overcharging or undercharging based on ambient temperature. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel, or AGM batteries.
  3. Flutuador Stage: Após a absorção stage timer concludes, the charger switches to a lower float voltage para manter a bateria com carga total sem sobrecarga.

7. Monitoramento

7.1. Victron Remote Management (VRM)

The Victron Remote Management (VRM) portal allows you to monitor, manage, and optimize your Victron Energy systems remotely. It helps identify potential issues early by setting alerts and alarms. VRM is free and works with a GX-device (such as the Cerbo GX) with an internet connection or the GlobalLink 520 for smaller systems.

Video 7.1.1: Introduction to Victron Remote Management (VRM) portal, demonstrating how to check remote systems at a glance, manage devices with simple controls, monitor system performance in detail, and design safety nets with programmable alerts and alarms.

Screenshot of the Victron Remote Monitoring (VRM) portal dashboard showing system overview, energy flow, and performance data.

Figure 7.1.2: Victron Remote Monitoring (VRM) Interface

7.2. Aplicação VictronConnect

The VictronConnect app allows you to configure, monitor, update, and diagnose your Victron product. It connects to Victron products via Bluetooth, USB, and WiFi/LAN/Internet, providing real-time data and control from your smartphone or tablet.

Video 7.2.1: Demonstration of the VictronConnect App, showing how to instantly check key monitoring data, see device performance, stay on top with simple controls, and perform easy configuration, firmware updating, and commissioning.

Multiple smartphone screens displaying the VictronConnect app interface, showing various monitoring and configuration options for Victron products.

Figure 7.2.2: VictronConnect App Interface

8. Manutenção

To ensure optimal performance and longevity of your Centaur battery charger, follow these general maintenance guidelines:

  • Regularly inspect the charger and its connections for any signs of damage, corrosion, or loose wiring.
  • Mantenha o carregador limpo e livre de poeira e detritos. Use um pano seco para a limpeza.
  • Garanta ventilação adequada ao redor da unidade para evitar superaquecimento.
  • Periodically check battery terminals for cleanliness and tightness.

9. Solução De Problemas

If you encounter issues with your Centaur charger, consider the following basic troubleshooting steps:

  • Sem energia: Check the AC input connection and ensure the power source is active. Verify all fuses and circuit breakers.
  • No Charging Output: Confirm battery connections are secure and correct polarity is observed. Check if the charger is in a fault state (refer to any indicator lights on the unit).
  • Superaquecimento: Ensure the charger has sufficient ventilation and is not obstructed. Verify ambient temperature is within operating limits.
  • Ruídos ou cheiros incomuns: Immediately disconnect power and contact qualified service personnel.

For complex issues or if troubleshooting steps do not resolve the problem, contact Victron Energy support or a certified technician.

10. Garantia e Suporte

The Victron Energy Centaur 24-Volt 16 amp 3 Bank Battery Charger comes with a Garantia de 5 ano. For warranty claims or technical support, please contact your authorized Victron Energy dealer or visit the official Victron Energy webSite com informações de contato e recursos de suporte.

Victron Energy Oficial Website: www.victronenergy.com

Documentos relacionados - CCH024016000

Préview Manual do Usuário do Carregador DC-DC Inteligente Isolado Victron Energy Orion-Tr
Este manual fornece informações detalhadas sobre o carregador CC-CC isolado Victron Energy Orion-Tr, abordando suas características, instalação, instruções de segurança e configuração por meio do aplicativo VictronConnect.
Préview Orion-Tr Smart Isolated DC-DC Charger User Manual
Comprehensive installation and operation manual for the Victron Energy Orion-Tr Smart Isolated DC-DC charger, covering setup, safety, and technical specifications.
Préview Victron Energy Orion-Tr Smart DC-DC Charger Isolated 250-400W User Guide and Specifications
Detailed information on the Victron Energy Orion-Tr Smart DC-DC charger, including features, specifications, and usage for isolated DC-DC charging applications in vehicles and boats.
Préview Manual do usuário e guia de instalação do carregador CC-CC isolado Victron Energy Orion-TR Smart.
Comprehensive user manual and installation guide for the Victron Energy Orion-Tr Smart DC-DC Charger Isolated. Covers safety, features, installation, engine shutdown detection, LED indicators, troubleshooting, specifications, VictronConnect app usage, and dimension drawings.
Préview Manual do Carregador Inteligente DC-DC Victron Energy Orion-Tr (Não Isolado)
Manual completo do carregador CC-CC inteligente não isolado Victron Energy Orion-TR, abrangendo instalação, recursos, segurança, solução de problemas, especificações e uso do aplicativo VictronConnect. Este dispositivo funciona como fonte de alimentação ou carregador de bateria, com compatibilidade com alternadores inteligentes e recursos avançados de proteção.
Préview Manual do inversor de energia Victron VE.Direct 120V (HW15) - Instalação e guia de derivação
Manual completo do inversor Victron Energy VE.Direct 120V (HW15). Inclua análises de instalação, detalhes de configuração, instrutor de deriva, especificações técnicas e dicas de aprendizagem detalhadas para todos os modeladores.

Ask a question about this manual