Introdução

This manual provides essential instructions for the installation, operation, maintenance, and troubleshooting of your APC Smart-UPS SRT 3000VA Rack Mount 120V Uninterruptible Power Supply (UPS). The Smart-UPS On-Line series offers powerful and efficient power protection with advanced management options, featuring Unity Power Factor and a graphical LCD interface for detailed information. This UPS is designed for critical applications in network closets, server rooms, retail offices, banking, medical labs, and industrial environments, ensuring continuous power and protection for connected equipment.

Informações de segurança

Please read and understand these safety instructions carefully before installing or operating the UPS. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Segurança elétrica: The UPS contains internal batteries and can produce hazardous voltages even when disconnected from the AC power source. Always disconnect the UPS from the main power supply before performing any service or maintenance.
  • Segurança da bateria: Batteries are heavy and contain hazardous chemicals. Refer to the battery replacement section for safe handling. Do not dispose of batteries in a fire; they may explode.
  • Ambiente de instalação: Install the UPS indoors in a controlled environment, free from excessive dust, corrosive fumes, and conductive contaminants. Ensure adequate airflow around the unit.
  • Peso: The UPS is heavy (approximately 68.9 pounds or 31.25 kg). Use proper lifting techniques or assistance during installation to prevent injury.
  • Aterramento: The UPS must be properly grounded. Do not defeat the grounding plug.
  • Proteção contra sobrecarga: Do not overload the UPS. Ensure the total load connected does not exceed the UPS's rated capacity.

Conteúdo da embalagem

Ao desembalar, verifique se todos os componentes estão presentes. Caso algum item esteja faltando ou danificado, entre em contato com seu revendedor ou com o serviço de atendimento ao cliente da APC.

  • APC Smart-UPS SRT 3000VA Rack Mount 120V Unit
  • Hardware de montagem em rack
  • Cabo de comunicação serial
  • Cabo de comunicação USB
  • CD de documentação
  • Safety instructions and warranty information

Configurar

1. Physical Installation (Rack Mount)

The SRT 3000VA is designed for installation in a standard 19-inch equipment rack. Due to its weight, it is recommended to use a lift or have at least two people for safe installation.

  • Prepare o suporte: Ensure the rack is stable and capable of supporting the UPS weight. Install the provided rack-mounting rails according to the instructions included with the hardware.
  • Mount the UPS: Carefully slide the UPS onto the installed rails. Secure the front of the UPS to the rack using the provided screws.
Frente view of APC Smart-UPS SRT 3000VA Rack Mount UPS

Imagem: Frente view of the APC Smart-UPS SRT 3000VA Rack Mount UPS, showing the LCD display and front panel.

2. Conexão de Equipamentos

Connect your critical equipment to the output receptacles on the rear panel of the UPS. Ensure that the total load does not exceed the UPS's capacity.

  • Potência de entrada: Connect the UPS input power cord to a properly grounded electrical outlet. The UPS requires a 120V input.
  • Receptáculos de saída: Plug your devices into the appropriate output receptacles. The UPS features multiple outlets, including a 30A maximum outlet and two groups of 20A maximum outlets.
  • Portas de comunicação: Connect the USB cable from the UPS to your computer or server for monitoring and graceful shutdown capabilities. Optionally, use the serial port for additional management.
  • Desligamento de Emergência (EPO): If required, connect an EPO switch to the EPO terminal block on the rear panel. Refer to the wiring diagram on the UPS for correct connection.
Traseira view of APC Smart-UPS SRT 3000VA Rack Mount UPS with power cord

Imagem: Traseira view of the APC Smart-UPS SRT 3000VA Rack Mount UPS, showing input power, output receptacles, USB, serial, and EPO ports.

3. Ligação inicial

  • Após conectar todos os cabos, pressione o botão liga/desliga no painel frontal para ligar o UPS.
  • The LCD display will illuminate and show the startup sequence.
  • Allow the UPS to perform its self-test and charge the batteries fully before relying on it for extended power backup.

Instruções de operação

1. Visor do painel frontal

The graphical LCD display provides real-time information about the UPS status, load, battery, and various settings. Use the navigation buttons (ESC, OK, Up, Down) to browse menus and adjust settings.

  • Indicador de carga: Exibe a porcentagemtage of the UPS's capacity currently being used.
  • Carga da bateria: Mostra o nível atual de carga da bateria.
  • Volume de saídatage: Indica o voltage being supplied to connected equipment.
  • Ícones de status: Provide quick visual cues for operational mode (e.g., Online, On Battery, Bypass) and alerts.

2. Operação básica

  • Ligar/desligar: Press the power button to turn the UPS on or off. A short press typically initiates a graceful shutdown sequence if configured.
  • Auto teste: The UPS performs a self-test automatically at startup and periodically. You can also initiate a manual self-test through the LCD menu to verify battery and UPS functionality.
  • Silêncio do Alarme: Most audible alarms can be temporarily silenced by pressing a button on the front panel. Critical alarms may not be silenced.

3. Gerenciamento de bateria

The UPS continuously monitors battery health. Regular battery self-tests and timely replacement are crucial for optimal performance.

  • Carregamento: The UPS charges its internal batteries whenever connected to utility power.
  • Tempo de execução: The LCD display can show estimated battery runtime based on the current load.
  • Battery Replacement Indicator: The UPS will indicate when batteries need replacement. Refer to the Maintenance section for details.

Manutenção

1. Substituição da bateria

Batteries are user-replaceable and hot-swappable, meaning they can be replaced without powering down connected equipment. However, always exercise caution.

  • Order Replacement Batteries: Use only APC-approved replacement battery cartridges (RBCs) for your model.
  • Segurança em primeiro lugar: Wear insulated gloves and safety glasses. Remove any metallic jewelry.
  • Access Battery: Refer to the UPS's specific battery access instructions, typically involving removing a front panel or cover.
  • Desconecte e remova: Disconnect the battery cables and carefully slide out the old battery cartridge. Note its orientation.
  • Instale uma nova bateria: Slide the new battery cartridge into the compartment, ensuring correct orientation. Reconnect the battery cables securely.
  • Recycle Old Batteries: Dispose of old batteries properly through an authorized recycling facility.

2. Limpeza

Keep the UPS free from dust and debris to ensure proper airflow and cooling.

  • Use um pano macio e seco para limpar a parte externa.
  • Não utilize produtos de limpeza líquidos ou solventes.
  • Certifique-se de que as aberturas de ventilação estejam livres de obstruções.

Solução de problemas

Esta seção fornece soluções para problemas comuns. Para problemas mais complexos, entre em contato com o suporte técnico da APC.

ProblemaPossível causaSolução
O nobreak não liga.Sem alimentação de entrada; bateria não conectada ou descarregada.Check input power cord connection; Ensure battery is connected and charged for several hours.
O nobreak emite bipes frequentemente.On battery mode; Overload; Low batteryCheck utility power; Reduce connected load; Allow battery to charge.
"Replace Battery" indicator is onBateria chegando ao fim da vida útilEncomende e instale um novo cartucho de bateria de substituição da APC.
O equipamento conectado perde energiaUPS overload; Battery discharged; UPS faultReduce load; Allow battery to recharge; Contact support if fault persists.

Especificações

Key technical specifications for the APC Smart-UPS SRT 3000VA Rack Mount 120V (Model: SRT3000RMXLA).

RecursoDetalhe
Número do modeloSRT3000RMXLA
Capacidade3000VA/2700W
Vol de entradatage120 V CA
Volume de saídatage120 V CA
Fator de formaRack Mount (2U)
Dimensões do produto (P x L x A)25" x 17.01" x 3.35" (63.5 cm x 43.2 cm x 8.5 cm)
Peso do item68.9 libras (31.25 kg)
Tipo de BateriaMaintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
Tempo de recarga típicoApproximately 3 hours to 90% capacity
Temperatura de operação32 - 104°F (0 - 40°C)
CertificaçõesUL, CSA, FCC Part 15 Class A, Energy Star

Garantia e Suporte

APC provides comprehensive warranty and support services for its products.

  • Informações sobre garantia: Refer to the warranty card included with your product or visit the official APC website para obter termos e condições detalhados da garantia.
  • Suporte técnico: For technical assistance, product inquiries, or troubleshooting beyond this manual, please contact APC customer support. Contact information can typically be found on the APC website ou na documentação do produto.
  • Recursos on-line: Visite o APC website for product registration, software downloads, FAQs, and additional documentation.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.