1. Produto acabadoview
The Kohler 76331-CP Shower Arm with 2-Way Diverter is a wall-mount fixture designed to direct water flow between a showerhead and a handshower. Constructed from brass, this unit features a polished chrome finish, engineered to resist corrosion and tarnishing. It includes a flange for installation and is compatible with standard 1/2-inch NPT connections.

Image 1.1: The Kohler 76331-CP Shower Arm with 2-Way Diverter, showcasing its polished chrome finish and integrated diverter mechanism.
2. Informações de segurança
- Sempre feche o registro geral de água antes de iniciar qualquer instalação ou manutenção.
- Use equipamento de proteção individual adequado, como óculos e luvas de segurança.
- Se tiver dúvidas sobre qualquer parte do processo de instalação, consulte um encanador qualificado.
- Certifique-se de que todas as conexões estejam seguras para evitar vazamentos.
- Do not overtighten connections, as this can damage the product or plumbing.
3. Conteúdo da embalagem
Verifique se todos os componentes estão presentes antes de iniciar a instalação.
- Shower Arm with 2-Way Diverter
- Flange
Note: Showerheads, handshowers, and additional flanges (K-76334 Traditional flange, K-76335 Square flange) are sold separately.
4. Especificações
| Recurso | Detalhe |
|---|---|
| Fabricante | Köhler |
| Número do modelo | 76331-CP |
| Número da peça | 76331-CP |
| Material | Construção de latão |
| Terminar | Cromo polido |
| Método de instalação | Montado na parede |
| Tipo de conexão | NPT de 1/2 pol. |
| Características especiais | Função desviadora |
| Peso do item | 1.1 libras |
| Dimensões do produto | 4.75 x 3.06 x 12.93 polegadas |
| Taxa de fluxo | 2.5 galões por minuto |
5. Instruções de instalação
5.1 Ferramentas e materiais necessários (não incluídos)
- Chave ajustável
- Plumber's tape (thread sealant)
- Pano macio
5.2 Etapas de instalação
- Desligue o abastecimento de água: Locate and turn off the main water supply to your shower area. Open existing shower faucets to relieve pressure.
- Remova o braço de chuveiro existente (se aplicável): Unscrew the existing shower arm from the wall fitting. Clean any old sealant or debris from the wall pipe threads.
- Prepare New Shower Arm: Apply plumber's tape clockwise around the threaded end of the new Kohler shower arm (the end that connects to the wall). Ensure several wraps for a watertight seal.
- Instalar flange: Slide the decorative flange over the shower arm, ensuring it faces the wall.
- Attach Shower Arm to Wall: Carefully thread the shower arm into the 1/2-inch NPT wall fitting. Hand-tighten first, then use an adjustable wrench to tighten an additional 1/2 to 1 full turn until secure and properly oriented. Do not overtighten.
- Flange de posição: Deslize a aba rente à parede para cobrir a abertura.
- Install Showerhead and Handshower: Attach your desired showerhead to the top outlet and your handshower hose to the bottom outlet of the diverter. Apply plumber's tape to these connections as well.
- Teste de vazamentos: Slowly turn the main water supply back on. Check all connections for leaks. If leaks occur, turn off water, tighten connections slightly, and re-test.
6. Instruções de operação
The 2-way diverter allows you to easily switch water flow between your main showerhead and a connected handshower.
- To use the Showerhead: Ensure the diverter handle is in the position that directs water upwards to the showerhead.
- To use the Handshower: Rotate the diverter handle to the position that directs water downwards to the handshower.
- To turn off water: Use your shower's main faucet handle to stop the water flow. The diverter only controls the direction of water, not the on/off function or temperature.
7. Manutenção e Cuidados
- Limpeza: Limpe o acabamento cromado polido com um pano macio e seco.amp pano. Evite produtos de limpeza abrasivos, produtos químicos agressivos ou esponjas de aço, pois podem danificar o acabamento.
- Limpeza de manchas: For water spots, use a mild soap solution and rinse thoroughly with clean water, then dry with a soft cloth.
- Inspeção regular: Periodically check connections for any signs of leaks or corrosion.
8. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| Vazamentos de água nas conexões | Loose connections; insufficient plumber's tape | Turn off water supply, tighten connections, reapply plumber's tape if necessary. |
| Diverter not switching flow completely | Debris in diverter mechanism; worn internal components | Flush the system by running water through both outlets. If problem persists, contact Kohler customer support. |
| Baixa pressão da água | Main water supply issue; clogged showerhead/handshower | Check household water pressure. Clean or replace showerhead/handshower if clogged. |
9. Garantia e Suporte
For specific warranty information and customer support, please refer to the official Kohler website or contact Kohler directly. Keep your purchase receipt for warranty claims.
Kohler Official Website: www.kohler.com