Elitech LogEt 8 THE

Manual de Instruções do Registrador de Dados de Temperatura e Umidade Digital Elitech LogEt 8 THE

Model: LogEt 8 THE

1. Produto acabadoview

The Elitech LogEt 8 THE is a reusable digital data logger designed for monitoring temperature and humidity. It is suitable for various applications, including cold chain management for pharmaceuticals, vaccines, food, and other sensitive products. This device features high precision sensors, multiple alarm thresholds, and direct USB connectivity for data download and report generation.

Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with external probe

Image: Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with its external probe. The device displays "32.9" and has "START" and "STOP" buttons.

2. Principais características

  • High-precision Temperature & Humidity Sensor: Wide temperature range from -40°F to 185°F with ±0.5°F accuracy. Humidity measuring range: 10%RH to 90%RH, with ±3%RH accuracy.
  • Vários alarmes: Configurable with up to 5 alarm thresholds (3 high, 2 low).
  • Plug and Read Functionality: Direct USB connection for data download without requiring a separate cable or reader.
  • Automatic PDF Report Generation: Encrypted PDF reports are automatically generated with password protection. Free Elitechlog software provides personalized settings and management.
  • Longa vida útil: Utilizes a replaceable lithium battery for extended operation.

3. Componentes do dispositivo

Diagram of Elitech LogEt 8 THE components

Image: Diagram illustrating the components of the Elitech LogEt 8 THE data logger. Key components include: 1. USB Port, 2. LCD Screen, 3. Buttons (START/STOP), 4. External Temperature and Humidity Sensor, and 5. Battery Cover.

  1. Porta USB: Used for connecting to a computer for data download and configuration.
  2. Tela LCD: Displays current temperature, humidity, and device status.
  3. Botões: "START" button to initiate logging, "STOP" button to cease logging.
  4. Sensor externo de temperatura e umidade: Provides accurate environmental readings.
  5. Tampa da bateria: Protects the replaceable lithium battery compartment.

4. Configuração

4.1 Inspeção Inicial

Upon receiving your LogEt 8 THE data logger, inspect the packaging and device for any signs of damage. Ensure all included components (data logger, calibration certificate, user manual) are present.

4.2 Instalação de software

Before first use, download and install the Elitechlog software from the official Elitech website. This software is required for device configuration, data download, and report generation.

  • Visite o site oficial da Elitech website.
  • Navigate to the support or download section.
  • Download the Elitechlog software compatible with your operating system (Windows/macOS).
  • Siga as instruções na tela para concluir a instalação.
Elitech LogEt 8 THE connected to a laptop for data export

Image: The Elitech LogEt 8 THE data logger plugged into a laptop's USB port, illustrating the data export process via ElitechLogWin software to PDF, Excel, or TXT formats.

4.3 Configuração do Dispositivo

Connect the data logger to your computer via the USB port. The Elitechlog software will detect the device. Use the software to configure parameters such as:

  • Intervalo de registro
  • Atraso de início
  • Alarm thresholds (high/low temperature and humidity)
  • Unidade de temperatura (°C/°F)
  • Fuso horário

Ensure the external temperature and humidity sensor is securely connected to the device before deployment.

5. Operação

5.1 Iniciando o registro de dados

Pressione e segure o COMEÇAR button for approximately 3 seconds until the "REC" indicator appears on the LCD screen. This indicates that the device has begun recording data according to the configured settings.

5.2 Interrompendo o registro de dados

Para interromper o registro, pressione e segure o PARAR button for approximately 3 seconds. The "REC" indicator will disappear from the LCD screen, confirming that logging has ceased.

5.3 Reading Data and Generating Reports

After logging is complete, connect the data logger to a computer via the USB port. The Elitechlog software will automatically recognize the device and prompt you to download the recorded data. The software will then generate an encrypted PDF report, which can also be exported to Excel or TXT formats for further analysis.

Elitech LogEt 8 THE generating a PDF report

Image: A visual representation of the Elitech LogEt 8 THE data logger connected to a computer, showing the generation of a PDF report. The report includes a graph of temperature and humidity data over time.

5.4 Proteção por senha

The generated PDF reports can be password-protected for enhanced data security. This feature is configured within the Elitechlog software.

6. Manutenção

6.1 Substituição da bateria

The LogEt 8 THE uses a replaceable lithium battery. When the battery indicator on the LCD screen shows low power, replace the battery to ensure continuous and accurate operation. To replace the battery:

  1. Locate the battery cover (Component 5 in the diagram).
  2. Abra cuidadosamente a tampa da bateria.
  3. Remove the old battery and insert a new compatible lithium battery, observing polarity.
  4. Feche a tampa da bateria com segurança.

6.2 Limpeza

Wipe the device clean with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is dry before use.

6.3 Armazenamento

When not in use for extended periods, store the data logger in a cool, dry place away from direct sunlight and extreme temperatures. Remove the battery if storing for very long durations to prevent leakage.

7. Solução De Problemas

ProblemaPossível causaSolução
O dispositivo não liga.Bateria fraca ou descarregada.Substitua a bateria.
Dados não registrados.Logging not initiated or stopped prematurely.Garantir o COMEÇAR button was pressed and held until "REC" appears. Check battery level.
Não consigo conectar ao computador/software.USB connection issue; software not installed or outdated.Ensure the device is fully inserted into the USB port. Verify Elitechlog software installation and update to the latest version. Try a different USB port.
Leituras imprecisas.Sensor obstruction or damage; device placed in extreme conditions.Ensure the external sensor is clean and unobstructed. Relocate the device to a suitable environment within its operating range.
PDF report not generated.Software error; insufficient disk space.Restart the Elitechlog software and try again. Ensure sufficient storage space on your computer.

8. Especificações

RecursoDetalhe
Número do modeloLogEt 8 O
Faixa de temperatura-40°F a 185°F (-40°C a 85°C)
Precisão da temperatura± 0.5 ° F (± 0.3 ° C)
Faixa de umidade10% RH a 90% RH
Precisão de umidade± 3% RH
Capacidade de gravação16000 pontos
ConectividadeUSB
Formato do RelatórioPDF (automatic, encrypted), Excel, TXT
Fonte de energia1 Lithium Metal battery (included, replaceable)
Dimensões do produto4 x 1.8 x 0.8 polegadas
Peso3.17 onças
Componentes incluídosData Logger, Calibration Certificate, User Manual
Elitech LogEt 8 THE temperature and humidity range

Image: The Elitech LogEt 8 THE data logger displaying its temperature range from -40°C/-40°F to 85°C/185°F and indicating a 16000 points record capacity.

9. Garantia e Suporte

Elitech provides US Technician Support via Email and Phone for any inquiries or issues you may encounter with your LogEt 8 THE data logger. Please refer to the official Elitech website or the included documentation for specific warranty terms and contact information.

For technical assistance, please visit the Elitech official website or contact their support team directly.

© 2023 Elitech. Todos os direitos reservados.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.