VC6243A

Generic VC6243A Digital LCR Meter User Manual

Model: VC6243A

1. Introdução

The Generic VC6243A is a portable digital LCR meter designed for measuring inductance (L), capacitance (C), and resistance (R). It features a liquid crystal display (LCD) with a 3 1/2 digit readout, double integral A/D conversion, and large-scale integrated circuits for accurate and reliable measurements. This manual provides detailed instructions for the safe and effective use of your VC6243A meter.

2. Informações de segurança

3. Produto acabadoview

Familiarize yourself with the components of your VC6243A Digital LCR Meter:

Labeled diagram of the VC6243A Digital LCR Meter showing its components.

Image 3.1: VC6243A Digital LCR Meter Components. This image displays the front panel of the VC6243A meter with labels pointing to its key features: LCD, Data Retention (DH) button, Power Switch, Capacitance ranges, Range Knob, Resistance ranges, Negative Input Terminal, Positive Input End, Inductance ranges, and Zeroing Knob.

4. Configuração

4.1 Instalação da bateria

The VC6243A meter requires one 9V laminated battery (6F22 type) for operation. The battery is not included with the device.

  1. Certifique-se de que o medidor esteja DESLIGADO.
  2. Localize o compartimento da bateria na parte traseira do medidor.
  3. Use uma chave de fenda para abrir a tampa do compartimento da bateria.
  4. Insira uma nova bateria de 9V, observando a polaridade correta (+ e -).
  5. Recoloque a tampa do compartimento da bateria e prenda-a com o parafuso.
Frente e verso view of the VC6243A Digital LCR Meter, showing the battery compartment on the back.

Image 4.1: VC6243A Front and Back View. This image shows both the front display and controls, and the back panel of the VC6243A meter, where the battery compartment is located.

4.2 Conectando os Cabos de Teste

Connect the provided crocodile clip test leads to the input terminals at the bottom of the meter. Ensure a secure connection.

VC6243A Digital LCR Meter with included accessories: carrying bag, instruction sheet, and crocodile clip test leads.

Image 4.2: VC6243A with Accessories. This image displays the VC6243A meter alongside its carrying bag, a small instruction sheet, and the red and black crocodile clip test leads.

5. Instruções de operação

5.1 Ligar/Desligar

Pressione o Interruptor de energia button located on the top right of the meter to turn it ON or OFF.

5.2 Selecting Measurement Function and Range

Rotate the central Botão de alcance to select the desired measurement function (Inductance 'L', Capacitance 'C', or Resistance 'R') and the appropriate range. The meter offers multiple ranges for each function to ensure accurate readings for various component values.

5.3 Zero Adjustment (ZERO ADJ)

Before measuring small inductance or capacitance values, it is recommended to perform a zero adjustment to compensate for residual values in the test leads or meter itself.

  1. Ensure the test leads are not connected to any component.
  2. Select the desired L or C range.
  3. Ajuste o AJUSTE ZERO knob until the display reads as close to zero as possible.

5.4 Realização de Medições

After selecting the function and range, connect the component to be measured to the crocodile clips. The reading will appear on the LCD.

5.5 Função de retenção de dados

Pressione o DH (Data Hold) button to freeze the current reading on the LCD. Press it again to release the hold and resume live measurements.

5.6 desligamento automático

The meter is equipped with an auto power-off function to conserve battery life. If no operation is performed for a certain period, the meter will automatically shut down. Press the power switch to turn it back on.

6. Especificações

RecursoEspecificação
MostrarLCD, 1999 counts (3 1/2 digits)
Método de MediçãoConversão A/D integral dupla
SampTaxa de ling3 vezes por segundo
Exibição acima da faixa"1" at the highest digit
Indicação de bateria fracaShowing "- +" symbol
Desligamento automáticoSim
Função de retenção de dadosSim
Faixas de capacitância200pF, 2nF, 20nF, 200nF, 2uF, 20uF, 200uF (±2.5% + 5 digits); 2000uF (±5% + 5 digits)
Faixas de indutância200uH (±3.0% + 5 digits); 2mH, 20mH, 200mH, 2H (±2.5% + 5 digits); 20H (±5% + 5 digits)
Faixas de resistência200Ω, 2kΩ, 20kΩ, 200kΩ (±0.8% + 5 digits); 2MΩ (±2% + 5 digits); 20MΩ (±5% + 5 digits)
Temperatura de trabalho0°C a 40°C (32°F a 104°F)
Temperatura de armazenamento-10°C a 50°C (14°F a 122°F)
Fonte de energiaOne 9V laminated battery (6F22 type)
Material da conchaabdômen
Dimensões190 x 91 x 40 mm (7.48 x 3.58 x 1.57 polegadas)

7. Manutenção

8. Solução De Problemas

9. Garantia e Suporte

Specific warranty information for the Generic VC6243A Digital LCR Meter is not provided in this manual. For details regarding warranty coverage, technical support, or service, please contact your original point of purchase or the product seller. Keep your purchase receipt as proof of purchase.

Documentos relacionados - VC6243A

Préview BM4070/VC6243A+ Digital Inductance Capacitance Resistance Meter Instructions
User manual and technical specifications for the BM4070/VC6243A+ digital meter, detailing inductance, capacitance, and resistance measurements, safety guidelines, features, operational procedures, and maintenance.