1. Introdução

The AOPUTTRIVER AP-570S-APP is a portable, high-performance digital clamp meter designed for accurate measurement of various electrical parameters. This device features Bluetooth connectivity, allowing it to pair with mobile phones for data logging and analysis. It is suitable for troubleshooting electrical problems in home improvement, appliance repair, line maintenance, and car repair applications.

AOPUTTRIVER AP-570S-APP Clamp Meter in various application scenarios

Image 1.1: The AP-570S-APP Clamp Meter being used in different electrical measurement scenarios, including home wiring, appliance repair, and automotive diagnostics.

2. Informações de segurança

Please read all safety warnings and operating instructions carefully before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Sempre certifique-se de que o clamp meter is in good working condition before use. Inspect for any damage to the casing, test leads, or insulation.
  • Não utilize o medidor se ele parecer danificado ou se o isolamento estiver comprometido.
  • Observe todas as normas de segurança locais e nacionais.
  • Evite trabalhar sozinho.
  • Tenha cuidado ao trabalhar com voltagacima de 30V AC RMS, 42V pico ou 60V DC. Essas tensõestagrepresentam um risco de choque.
  • Always disconnect power to the circuit under test before making connections or disconnections, especially when measuring resistance, capacitance, or performing diode tests.
  • The AP-570S-APP features a double insulation design for enhanced protection. However, always exercise caution.
  • O Vol Sem Contatotage (NCV) detection feature allows for voltage detection without direct contact, improving safety.
  • Replace the battery promptly when the low battery indicator appears to ensure accurate readings and proper operation.
AOPUTTRIVER AP-570S-APP Clamp Meter highlighting safety features

Image 2.1: The clamp meter with a rubber sleeve for protection against drops and emphasizing safety features like double insulation.

3. Recursos do Produto

  • Multifunction Measurement: Accurately measures AC/DC Voltage (600mV-1000V), AC/DC Current (600A-1000A), Resistance (600Ω-60MΩ), Capacitance (6nF-60mF), Frequency (9.999Hz-9.999MHz), Duty Cycle, Diode, and Continuity.
  • Bluetooth APP Connectivity: Connects to mobile phones (Android/iOS) via Bluetooth for real-time data display, logging, and analysis using the "AiLink" app.
  • Medição de temperatura: Includes a thermocouple for temperature testing, with switchable units (℃/℉).
  • Vol sem contatotage (NCV) Detecção: Detecta com segurança a tensão CAtage without direct contact, indicated by sound and light.
  • Exibição da luz de fundo: Large LCD with backlight for clear readings in dark environments.
  • Dados em espera: Congela a leitura atual no visor.
  • Função MÁX/MÍN: Records maximum and minimum measured values.
  • REL (Relative) Mode: Measures the change in a signal relative to a stored reference value.
  • Ajuste automático/manual de alcance: Offers flexibility in measurement ranges.
  • Double Insulation Design: Provides enhanced user safety.
  • Desligamento automático: Economiza a vida útil da bateria.

4. Layout Introduction (Components)

Familiarize yourself with the different parts of your AOPUTTRIVER AP-570S-APP Clamp Medidor:

Diagram of AOPUTTRIVER AP-570S-APP Clamp Componentes do medidor

Image 4.1: Detailed diagram showing the layout and functions of the clamp meter's various parts.

  1. Clamp Maxilas: Opens up to 45mm to enclose a conductor for current measurement.
  2. NCV Detection Area: Area for non-contact voltage detecção.
  3. Jaw-Opening Handle: Usado para abrir e fechar a fechadura.amp mandíbulas.
  4. Interruptor rotativo: Selects measurement functions and ranges.
  5. Tecla HOLD: Press to hold the current reading. Press and hold for more than 2 seconds to activate/deactivate backlight.
  6. Chave de seleção: Used to switch between functions within a rotary switch position (e.g., AC/DC voltage, diode/continuity, capacitance).
  7. Tecla MÁX/MÍN: Press to display the maximum or minimum measured value. Press and hold for 2 seconds to exit.
  8. Chave REL: Ativa o modo de medição relativa.
  9. Hz/Duty Key: In ACV/ACA or Hz range, press to choose between Frequency (Hz) or Duty Cycle measurement.
  10. Tela LCD: 6000 counts digital display with full function symbols.
  11. Conector de entrada COM: Entrada comum (negativa) para cabos de teste.
  12. VΩHzT+ Input Jack: Entrada positiva para voltage, resistance, frequency, temperature, and capacitance measurements.

5. Configuração

5.1 Instalação da bateria

The AP-570S-APP requires a 9V battery for operation. To install or replace the battery:

  1. Garanta o clamp meter is turned OFF (Rotary Switch set to OFF).
  2. Localize a tampa do compartimento da bateria na parte traseira do medidor.
  3. Use uma chave de fenda para abrir o compartimento da bateria.
  4. Conecte a bateria de 9V aos terminais da bateria, observando a polaridade correta.
  5. Place the battery into the compartment and secure the cover.

5.2 Inicialização Inicial

After battery installation, turn the Rotary Switch from OFF to any desired measurement function to power on the device. The LCD display will illuminate.

AOPUTTRIVER AP-570S-APP Clamp Meter and included accessories

Image 5.1: The clamp meter shown with its packaging, carrying bag, test leads, thermocouple, and 9V battery.

6. Instruções de operação

To perform measurements, rotate the Rotary Switch to the desired function. Connect test leads or use the clamp jaws as appropriate for the measurement type.

6.1 Medição de corrente CA/CC

  1. Set the Rotary Switch to the 600 A ~ 1000 A posição.
  2. Pressione o SELECIONAR key to switch between AC (~) and DC (—) current measurement if necessary.
  3. Abra o clamp jaws using the jaw-opening handle.
  4. Enclose only one conductor with the clamp jaws. Ensure the conductor is centered within the jaws for accurate readings.
  5. Leia o valor atual no visor LCD.

Note: For currents between 0-600A, resolution is 0.1A. For 600-1000A, resolution is 1.0A.

6.2 Vol AC/DCtage Medição

  1. Set the Rotary Switch to the V— or V~ posição.
  2. Pressione o SELECIONAR key to switch between AC (~) and DC (—) voltage measurement if necessary.
  3. Insira a ponta de prova preta no COM jack e o fio de teste vermelho no VΩHzT+ Jack.
  4. Conecte as pontas de prova ao circuito ou componente a ser medido.
  5. Leia o vol.tage valor no display LCD.

6.3 Medição de resistência, diodo, continuidade e capacitância

  1. Set the Rotary Switch to the Ω posição.
  2. Pressione o SELECIONAR key to cycle through Resistance (Ω), Diode Test (→|), Continuity Test (♫), and Capacitance (—||—) functions.
  3. Insira a ponta de prova preta no COM jack e o fio de teste vermelho no VΩHzT+ Jack.
  4. Conecte as pontas de prova ao componente.
  5. Read the value on the LCD display. For continuity, an audible beep indicates a continuous circuit.

6.4 Medição de Frequência e Ciclo de Trabalho

  1. Set the Rotary Switch to the Hz posição.
  2. Insira a ponta de prova preta no COM jack e o fio de teste vermelho no VΩHzT+ Jack.
  3. Connect the test probes to the signal source.
  4. Pressione o Hz/Serviço key to switch between Frequency (Hz) and Duty Cycle (%).
  5. Leia o valor no display LCD.

6.5 Medição de Temperatura

  1. Set the Rotary Switch to the ° C / ° F posição.
  2. Insert the thermocouple into the COM e VΩHzT+ jacks, observando a polaridade.
  3. Coloque a sonda termopar no ponto onde a temperatura deve ser medida.
  4. Pressione o SELECIONAR Tecla para alternar entre Celsius (°C) e Fahrenheit (°F).
  5. Leia o valor da temperatura no visor LCD.
AOPUTTRIVER AP-570S-APP Clamp Meter performing temperature measurement

Image 6.1: The clamp meter displaying temperature readings in both Celsius and Fahrenheit, with a thermocouple probe immersed in water.

6.6 Volume sem contatotage (NCV) Detecção

  1. Set the Rotary Switch to the VNC posição.
  2. Move the NCV detection area of the meter close to the wire or conductor where voltage is suspected.
  3. Se AC voltage is detected, the meter will emit an audible beep and the NCV indicator light will illuminate.
AOPUTTRIVER AP-570S-APP Clamp Meter performing NCV detection

Image 6.2: The clamp meter detecting non-contact voltage near an electrical outlet, indicated by a red glow and 'bi bi' sound representation.

6.7 Função de retroiluminação

To activate or deactivate the backlight, press and hold the SEGURAR button for more than 2 seconds. The backlight improves visibility in dimly lit conditions.

AOPUTTRIVER AP-570S-APP Clamp Meter LCD display with and without backlight

Image 6.3: Comparison of the clamp meter's LCD display, showing improved readability with the backlight activated.

7. Bluetooth APP Connection

The AP-570S-APP can connect to your mobile device via Bluetooth for enhanced functionality, including data logging and analysis.

  1. Baixe o aplicativo: Scan the QR code below or search for "AiLink" in the Google Play Store (for Android) or Apple App Store (for iOS). Download and install the application.
  2. Cadastre-se/Faça login: Open the AiLink app. You may need to register a new account or log in using an existing account (e.g., Facebook or Apple ID).
  3. Conecte o Clamp Medidor: Ensure Bluetooth is enabled on your mobile phone. In the AiLink app, press the "ADD" or "+" button to search for nearby devices. Select the clamp meter from the list to connect.
  4. Start Measurement and Analysis: Uma vez conectado, você pode view real-time data, save measurements, and analyze them within the app. The app allows for data export (e.g., CSV filee).
Steps to connect AOPUTTRIVER AP-570S-APP Clamp Meter to mobile app

Image 7.1: Visual guide demonstrating the steps to download the AiLink app, log in, connect to the clamp meter, and view dados.

Download AiLink App: https://aicare.net.cn/app/ailink/download/

8. Manutenção

  • Limpeza: Regularly wipe the meter casing com anúncioamp pano e detergente neutro. Não use produtos abrasivos ou solventes.
  • Substituição da bateria: Replace the 9V battery when the low battery indicator appears on the display. Always turn off the meter before replacing the battery.
  • Armazenar: If the meter is not used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Calibração: For professional use, periodic calibration by a qualified technician is recommended to ensure continued accuracy.

9. Solução De Problemas

Problema Possível causa Solução
O medidor não liga. Bateria descarregada ou instalada incorretamente. Verifique a polaridade da bateria ou substitua-a por uma nova bateria de 9V.
Leituras imprecisas. Low battery; incorrect function selected; external interference. Replace battery; ensure correct function is selected; move away from strong electromagnetic fields.
A conexão Bluetooth falha. Bluetooth not enabled on phone; app issues; meter too far from phone. Ensure phone Bluetooth is on; restart app/phone; bring meter closer to phone; ensure app permissions are granted. Some users report issues with the app requiring an account or network errors; try reinstalling the app or checking for updates.
Sem sinal sonoro de continuidade. Circuit is open; incorrect function selected. Verify the circuit is closed; ensure the continuity function is selected.
A luz de fundo não está funcionando. Backlight function not activated; low battery. Press and hold the HOLD button for 2 seconds; replace battery.

10. Especificações

Parâmetro Valor
Número do modelo AP-570S-APP
Marca AOPUTTRIVER
Mostrar LCD de 6000 contagens
Vol. CAtage Alcance 6V ~ 750V
Vol. DCtage Alcance 600mV ~ 1000V
Faixa de corrente AC 600A ~ 1000A
Faixa de corrente DC 600A ~ 1000A
Faixa de resistência 600Ω ~ 60MΩ
Faixa de capacitância 6nF ~ 60mF
Faixa de frequência 9.999Hz ~ 9.999MHz
Faixa de temperatura Thermocouple dependent (e.g., -20°C to 1000°C)
Abertura da mandíbula 45 mm
Fonte de energia Bateria 9V (incluída)
Peso 330 gramas
Dimensões 25.8 x 12.6 x 5.8 cm (Pacote)
Conformidade de segurança CE Marked, RoHS Compliant, Digital Multimeter Standards

11. Garantia e Suporte

AOPUTTRIVER products are designed for reliability and performance. For warranty information or technical support, please refer to the documentation included with your purchase or contact AOPUTTRIVER customer service directly. If you have questions about the product during daily use, please contact us for assistance.