1. Introdução
The KKmoon KKM828 is a versatile 2-in-1 device combining the functionalities of a digital multimeter and an oscilloscope. Designed for efficiency and accuracy, it features a 2.4-inch color display, a 1MHz bandwidth for AC voltage, and a 2.5Msps real-time sampling rate. This manual provides essential information for safe and effective operation of your KKM828 device.
2. Informações de segurança
Please read and understand all safety instructions before using the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device or other equipment.
- Always ensure the device is in good working condition and free from damage before use.
- Não aplicar voltage or current that exceeds the maximum limits specified in the technical specifications.
- Tenha cuidado ao trabalhar com voltages above 24V, as they pose a shock hazard. The device will emit an audible warning if the input voltage excede 24V.
- Certifique-se de selecionar a função e o intervalo corretos antes de efetuar as medições.
- Substitua as pilhas imediatamente quando o indicador de bateria fraca aparecer para garantir leituras precisas.
- The device is equipped with double fuses (500mA/250V and 10A/250V) for protection. Do not bypass or use incorrect fuse types.
- Do not operate the device in wet environments or explosive atmospheres.
- Refer to the "Maintenance" section for proper cleaning and storage procedures.
3. Produto acabadoview
The KKmoon KKM828 integrates a digital multimeter and an oscilloscope into a compact, handheld unit. Key components and features are detailed below.
3.1 Principais Características
- Funcionalidade 2 em 1: Combines a digital multimeter and an oscilloscope.
- Mostrar: 2.4-inch 320x240 LCM color screen for clear readings and waveform display.
- Oscilloscope Performance: 1MHz ACV bandwidth, 2.5Msps real-time samptaxa de crescimento.
- Funções do multímetro: Mede volume CA/CCtage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode, and continuity.
- Armazenamento de dados: Stores up to 100 sets of data and 10 waveforms.
- Interface do usuário: Silicone buttons and a pressure-sensitive dial for precise function selection.
- Ergonomia: Integrated back bracket for a 60° viewângulo de engate.
- Segurança: Double fuse protection (500mA/250V, 10A/250V) and input voltage aviso.
3.2 Componentes do dispositivo
Consulte a imagem abaixo para obter uma visão geral.view of the device's main components.

Figure 1: KKM828 Product Details. This image highlights the device's HD color screen (01), the function dial for accurate gear changes (02), and the back bracket (03) for easy viewindo.
- Tela HD: 2.4-inch color screen for clear display of measurements and waveforms.
- Seletor de funções: Rotary switch for selecting measurement functions (voltage, current, resistance, etc.) and oscilloscope mode.
- Buttons (F1-F4, R, S): Used for navigating menus, selecting ranges, holding data, and other specific functions.
- Jacks de entrada: Terminals for connecting test leads for various measurements (e.g., VΩHz, mA, 10A, COM).
- Suporte traseiro: Foldable stand for propping up the device at a 60° angle for convenient viewindo.
4. Configuração
4.1 Instalação da bateria
The KKM828 requires three AA batteries for operation. Ensure the device is powered off before installing or replacing batteries.
- Localize a tampa do compartimento da bateria na parte traseira do dispositivo.
- Open the battery compartment cover by sliding or unscrewing it (if applicable).
- Insert three AA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Feche bem a tampa do compartimento da bateria.
4.2 Ligar/Desligar
To power on the device, rotate the function dial from the "OFF" position to any desired measurement function. To power off, rotate the dial back to the "OFF" position.
5. Instruções de operação
5.1 Funções do Multímetro
The KKM828 offers a comprehensive range of multimeter measurement capabilities. Always connect test leads correctly to the appropriate input jacks (e.g., COM, VΩHz, mA, 10A) for the selected function.
- AC / DC Voltage Medição: Rotate the dial to the 'V~' or 'V=' position. Connect test leads in parallel with the circuit.
- Medição de Corrente CA/CC: Rotate the dial to the 'mA~', 'mA=', '10A~', or '10A=' position. Connect test leads in series with the circuit.
- Medição de Resistência: Rotate the dial to the 'Ω' position. Ensure the circuit is de-energized before measuring resistance.
- Medição de capacitância: Rotate the dial to the 'mF' position. Discharge capacitors before measurement.
- Frequency and Duty Cycle Measurement: Rotate the dial to the 'Hz%' position.
- Teste de Diodo: Rotate the dial to the 'Diode' position. Connect leads across the diode to check forward voltage gota.
- Teste de continuidade: Rotate the dial to the 'Continuity' position. The device will beep if resistance is below approximately 50Ω.

Figure 2: Multimeter Measurement Examples. This image illustrates the display during Frequency, Duty Cycle, Diode Test, and Continuity measurements, demonstrating the device's various multimeter functions.
5.2 Funções do Osciloscópio
The KKM828 features a convenient one-button oscilloscope for waveform analysis.
- Rotate the function dial to the 'Graphical' (oscilloscope) mode.
- Connect the test leads to the circuit where you wish to observe the waveform.
- The device will automatically display the waveform. Use the secondary display at the bottom to view parameters such as Peak-to-Peak voltage (VP-P), average value, RMS value, frequency, time base, and ampsolidão.
- Measurement modes include 'Normal' and 'Automatic'. The device can quickly and accurately measure and display waveforms.

Figure 3: Oscilloscope Waveform Display. Esta imagem mostra examples of different electrical waveforms (sine, square, pulse, complex) as displayed on the KKM828's oscilloscope screen, along with key measurement parameters.
5.3 Armazenamento e Recuperação de Dados
The KKM828 can store up to 100 sets of measurement data and 10 waveforms for later review.
- Specific instructions for saving and recalling data are typically accessed via the function buttons (e.g., 'S' for Save, 'R' for Recall) in relevant measurement modes. Refer to the on-screen prompts for detailed operation.
- The device allows for simultaneous display of historical records and real-time data for easy comparison and analysis.
6. Manutenção
6.1 Limpeza
To clean the device, wipe the casing com anúncioamp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning. Do not allow moisture to enter the device.
6.2 Substituição da bateria
When the low battery indicator appears on the display, replace the three AA batteries as described in the "Battery Installation" section (4.1). Always use fresh batteries of the same type.
6.3 Armazenamento
When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place within the specified storage environment: -10°C to 60°C, with relative humidity less than 90% RH.
7. Solução De Problemas
This section addresses common issues you might encounter with your KKM828 device.
| Problema | Possível causa | Solução |
|---|---|---|
| O dispositivo não liga. | Baterias descarregadas ou instaladas incorretamente. | Verifique a polaridade das pilhas e substitua-as por pilhas AA novas. |
| Nenhuma leitura ou "OL" (Sobrecarga) exibido. | Incorrect range selected, open circuit, or input exceeds maximum limit. | Select appropriate range, check test lead connections, ensure circuit is closed. Verify input does not exceed specifications. |
| Medições imprecisas. | Low battery, incorrect connection, or environmental factors. | Replace batteries, re-check test lead connections, ensure operating environment is within specified range. |
| Oscilloscope waveform is unstable or absent. | Poor connection, signal too weak/strong, or incorrect mode. | Ensure secure test lead connection. Adjust amplitude or time base if available (though KKM828 is mostly auto-ranging). Verify signal source. |
| O dispositivo emite bipes continuamente. | Vol de entradatage exceeds 24V (safety warning). | Immediately disconnect the device from the circuit and verify the voltage level. Do not proceed if voltage é muito alto. |
8. Especificações
The following table details the technical specifications of the KKmoon KKM828.
| Parâmetro | Valor |
|---|---|
| Modelo | KKM828 |
| Mostrar | 2.4-inch 320 x 240 LCM Color Screen |
| Resistência de entrada | 10 MOhms |
| Tipo de Bateria | 3 pilhas AA (não incluídas) |
| Consumo de energia | Aproximadamente. 80 mA |
| Operating Time (low brightness) | Aproximadamente 5 horas |
| Armazenamento de dados | 100 data sets / 10 waveforms |
| Ambiente operacional | 0 ~ 40 °C, <75% RH |
| Ambiente de armazenamento | -10 ~ 60 °C, <90% RH |
| Bandwidth (ACV) | 1 MHz |
| Bandwidth (ACA) | 5 kHz |
| Max. Real-time SampTaxa de ling | 2.5 Msps |
| Multimeter Range (DC Voltage) | 400mV / 4V / 40V / 400V / 1000V (Accuracy: 0.75% rdg + 10dgt) |
| Multimeter Range (AC Voltage) | 400mV / 4V / 40V / 400V / 750V (Accuracy: 1.0% rdg + 10dgt) |
| Multimeter Range (DC Current) | 40mA / 400mA / 4A / 10A (Accuracy: 1.2% rdg + 10dgt) |
| Multimeter Range (AC Current) | 40mA / 400mA / 4A / 10A (Accuracy: 1.5% rdg + 10dgt) |
| Multimeter Range (Resistance) | 400.0 Ω ~ 40.00 MΩ (Accuracy: 1.0% rdg + 5dgt) |
| Multimeter Range (Capacitance) | 0.1nF ~ 100, 10.00mF (Accuracy: 2.0% rdg + 10dgt) |
| Multimeter Range (Frequency) | 5Hz ~ 10MHz (Accuracy: 1.0% rdg + 5dgt) |
| Multimeter Range (Duty Cycle) | 0.1 % ~ 99.9 % (Accuracy: 1.0% rdg + 5dgt) |
| Teste de diodo | Volumetage approx. 5V, Test current approx. 1.5mA |
| Teste de continuidade | Buzzer sounds if resistance < 50Ω |
| Especificações do fusível | 500mA / 250V, 10A / 250V |
| Dimensões | 160 x 83 x 32 mm |
| Peso | 195 g |