1. Introdução
The AOPUTTRIVER AP-189A is a high-precision digital manometer designed for measuring differential, positive, and negative pressure. It is widely used in various applications including flow measurement, air quality monitoring, level measurement, gas temperature measurement, and HVAC system control. This manual provides detailed instructions for the safe and effective use of your device.
The device features a large LCD with backlight, data hold function, automatic power-off, and the ability to record maximum, minimum, and average values, as well as differential pressure (DIF). It supports 11 selectable pressure units for versatility in professional applications.
2. Recursos do Produto
- Alta precisão: Measurement range of ±2.000psi with an accuracy of ±0.3%FSO (at 25°C).
- Múltiplas Unidades: Easily switch between 11 pressure units: Psi, kPa, Kgfcm2, ozin2, Bar, mbar, inHg, mmHg, inH2O, ftH2O, cmH2O.
- Gravação de dados: Records MAX/MIN/AVG values for easy data analysis.
- Configuração zero: Allows for precise zero calibration before measurements.
- Visor multifuncional: Large LCD with backlight for clear readings.
- Gerenciamento de energia: Low battery indicator and automatic power-off after 25 minutes of inactivity to conserve battery life.
- DIF Function: Measures differential pressure.

Imagem: Acimaview of the AP-189A Digital Manometer's key features and specifications, including accuracy, repeatability, maximum pressure, and various functions like data hold, auto-off, and unit selection.
3. Conteúdo da embalagem
Ao abrir a embalagem, verifique se todos os itens estão presentes e em boas condições:
- 1 x AP-189A Digital Manometer
- 1 x Bolsa protetora
- 1 x Small Screwdriver
- 2 pilhas AAA de 1.5 V
- 1 x User Manual (Japanese)

Image: The complete package contents of the AP-189A Digital Manometer, showing the device, a protective carrying bag, a small screwdriver, two AAA batteries, and the user manual.
4. Configuração
4.1 Instalação da bateria
- Localize a tampa do compartimento da bateria na parte traseira do dispositivo.
- Use the provided small screwdriver to open the battery compartment.
- Insira duas pilhas AAA de 1.5V, certificando-se da polaridade correta (+/-).
- Recoloque a tampa do compartimento da bateria e prenda-a com o parafuso.
4.2 Conexão das Mangueiras
The AP-189A features dual ports for differential pressure measurement. Connect the hoses to the appropriate ports (+ and -) based on your measurement requirements. Ensure a secure connection to prevent leaks.

Imagem: Uma imagem detalhada view of the AP-189A Digital Manometer, highlighting its dimensions and the dual port connections at the top for pressure hoses.
5. Instruções de operação
5.1 Ligar/Desligar
- Pressione o Botão de energia (
) to turn the device ON. - Pressione e segure o Botão de energia for a few seconds to turn the device OFF.
5.2 Configuração de zero
Before taking any measurements, it is crucial to perform a zero setting to ensure accuracy. Disconnect all pressure hoses from the device before performing this step.
- Ensure the device is powered on and no pressure is applied to the ports.
- Pressione e segure o SEGURAR botão por aproximadamente 5 segundos.
- The display will show "----" indicating that the zero setting is complete.

Image: Visual guide demonstrating how to perform a zero setting on the manometer by long-pressing the HOLD button until the display shows dashes.
5.3 Seleção de Unidade
Pressione o UNIDADE button to cycle through the 11 available pressure units (Psi, kPa, Kgfcm2, ozin2, Bar, mbar, inHg, mmHg, inH2O, ftH2O, cmH2O) until your desired unit is displayed.
5.4 Função de retroiluminação
Pressione o Botão de luz de fundo (
) to turn the LCD backlight ON or OFF for improved visibility in low-light conditions.
5.5 Retenção de dados
Pressione o SEGURAR button briefly to freeze the current reading on the display. Press it again to release the hold function and resume live readings.
5.6 MAX/MIN/AVG/DIF Recording
Pressione o REC button to enter recording mode. In this mode, the device will track the maximum, minimum, and average pressure values. Press REC repeatedly to cycle through MAX, MIN, AVG, and DIF displays. To exit recording mode, press and hold the REC botão.
5.7 Desligamento Automático
The device will automatically power off after 25 minutes of inactivity to save battery life. This feature can typically be disabled or adjusted by pressing and holding specific buttons during power-on, as detailed in the full manual.

Image: A close-up of the AP-189A's LCD screen and control buttons, illustrating the functions of the Power, Hold, Unit, Backlight, Record, and DIF buttons.
6. Manutenção
- Limpeza: Limpe o dispositivo com um pano macio e seco. Não utilize produtos de limpeza abrasivos ou solventes.
- Armazenar: Store the manometer in its protective bag in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Calibração: Regular calibration by a qualified technician is recommended to maintain measurement accuracy, especially for critical applications.
- Substituição da bateria: Replace batteries promptly when the low battery indicator appears to ensure continuous operation and prevent data loss.
7. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| O dispositivo não liga | Baterias gastas ou instaladas incorretamente | Verifique a polaridade da bateria; substitua as baterias. |
| Leituras imprecisas | No zero setting performed; sensor obstruction; device not calibrated | Perform zero setting; ensure ports are clear; consider professional calibration. |
| Display shows "OL" or "Err" | Overload (pressure exceeds maximum limit) | Remove pressure immediately. Ensure pressure does not exceed 6 Psi. |
| A luz de fundo não funciona | Backlight function off; low battery | Press the backlight button; replace batteries. |
8. Especificações
- Faixa de medição: ± 2.000 psi
- Precisão: ±0.3%FSO (at 25°C)
- Repetibilidade: ±0.25%FSO
- Linearity/Hysteresis: ±0.1%FSO
- Limited Maximum Pressure: 6 Psi
- Unidades: Psi, kPa, Kgfcm2, ozin2, Bar, mbar, inHg, mmHg, inH2O, ftH2O, cmH2O
- Funções: Backlight, Data Hold, Auto Power Off (25 min), MAX/MIN/AVG/DIF, Zero Setting
- Fonte de energia: 2 pilhas AAA de 1.5 V
- Dimensões: Dimensões aproximadas: 166 mm x 62 mm x 31 mm (6.29 pol x 2.44 pol x 1.22 pol)
- Peso: Aproximadamente 250g

Image: A diagram illustrating the physical dimensions of the AP-189A Digital Manometer, including length, width, and thickness.
9. Garantia e Suporte
The AOPUTTRIVER AP-189A Digital Manometer comes with a 365-day warranty and lifetime technical support. If you encounter any quality issues with the product, please contact our customer support team. We are committed to resolving any problems as quickly as possible.
For support, please refer to the contact information provided in your product packaging or visit the official AOPUTTRIVER website.