1. Produto acabadoview
The Walfront 200EP Wire Tracker Kit is a versatile tool designed for efficient cable and wire maintenance. It enables users to trace wires, identify cables within common wiring systems, and diagnose issues in telephone, data, internet, audio, security, and communication cables. The kit features high sensitivity and accuracy, providing both audible and visual indicators for easy identification of tone signatures.

Image 1.1: The Walfront 200EP Wire Tracker Kit, including the toner (left) and probe (right) units, along with various connection cables.
2. Informações de segurança
- AVISO: Do not test cables while they are powered on. Ensure all circuits are de-energized before testing to prevent electric shock or damage to the device.
- Always use the device in accordance with local electrical safety regulations.
- Mantenha o dispositivo longe de água e umidade.
- Não tente abrir ou modificar o dispositivo. Encaminhe todos os serviços de manutenção a pessoal qualificado.
- Guarde o dispositivo em local seco e fresco quando não estiver em uso.
3. Conteúdo da embalagem
Por favor, verifique se a embalagem contém os seguintes itens:
- 1 x Cable Toner (Detector)
- 1 x Probe (Receiver)
- 1 x Test Head (Cable with various connectors)
- 1 x Manual do Usuário (Este documento)
- 1 x Bolsa de Armazenamento
Observação: A 9V 6F22 battery is required for operation and is not included in the package.
4. Configuração
4.1 Instalação da bateria
- Locate the battery compartment on both the Cable Toner and the Probe units.
- Abra a tampa do compartimento da bateria.
- Insert one 9V 6F22 battery into each unit, ensuring correct polarity (+/-).
- Feche bem a tampa do compartimento da bateria.
4.2 Connecting the Toner
- Connect the test head cable to the Cable Toner unit.
- Depending on the cable type you are testing, use the appropriate connector (e.g., RJ11 for telephone lines, RJ45 for network cables, or alligator clips for bare wires) to connect the toner to the cable you wish to trace.
- Ensure the cable is disconnected from any active equipment and is not live.
5. Instruções de operação
5.1 Wire Tracing
- Connect the Cable Toner to the target cable as described in Section 4.2.
- Turn on the Cable Toner. It will generate a tone signal onto the cable.
- Turn on the Probe (Receiver) unit.
- Adjust the sensitivity of the Probe using its control dial for optimal detection.
- Move the tip of the Probe along the path of the suspected cable. The Probe will emit an audible tone and/or illuminate an LED indicator when it detects the signal from the toner.
- Follow the strongest signal to accurately trace the cable's path.

Image 5.1: The Walfront 200EP Probe (Receiver) unit, used for detecting the tone signal.
5.2 Short Circuit and Polarity Testing
- Some models of the 200EP toner may offer additional functions like short circuit detection or polarity testing. Refer to the markings on your specific toner unit for these features.
- Typically, these functions involve connecting the toner to the cable and observing LED indicators or tone changes on the toner itself to determine circuit status or polarity.
6. Manutenção
- Limpeza: Limpe o dispositivo com um pano macio e seco. Não utilize produtos de limpeza abrasivos ou solventes.
- Substituição da bateria: Replace batteries when the indicator light dims or the device performance degrades. Always use fresh 9V 6F22 batteries. Remove batteries if the device will not be used for an extended period to prevent leakage.
- Armazenar: Store the kit in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Solução De Problemas
- Sem sinal/Sinal fraco:
- Verifique se as baterias estão instaladas corretamente e têm carga suficiente.
- Ensure the Cable Toner is turned on and properly connected to the cable.
- Increase the sensitivity on the Probe unit.
- Verify the cable is not live or connected to other equipment that might interfere with the signal.
- Sem energia:
- Verifique a instalação da bateria e substitua-a por novas.
- Certifique-se de que o interruptor de alimentação esteja na posição 'LIGADO'.
- Interferência:
- External electrical noise can affect tracing. Try to minimize sources of interference.
- Ensure the cable being traced is isolated from other active cables if possible.
8. Especificações
| Recurso | Especificação |
|---|---|
| Tipo de produto | Wire Tracking Kit |
| Modelo | 200EP |
| Marca | Walfront |
| Material | abdômen |
| Fonte de energia | Battery Powered (9V 6F22 x 1 per unit, not included) |
| Vol operacional mínimotage | 9 Volts |
| Ganho | 30 dB |
| Resistência de entrada | 100 MOhms |
| Probe Tip Resistance (Metal) | 0 Ohm |
| Probe Tip Resistance (Plastic) | 300 Ohm |
| Peso do item | 294 gramas |
9. Garantia e Suporte
Para informações sobre garantia e suporte técnico, consulte a documentação fornecida no momento da compra ou entre em contato com o revendedor. Guarde o comprovante de compra como prova de aquisição.