Rebel RB-4003

Rebel POWER-1000 Pure Sine Wave UPS Inverter User Manual

Model: RB-4003 | Brand: Rebel

1. Introdução

Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.

2. Instruções de segurança

Observe sempre as seguintes precauções de segurança para evitar ferimentos ou danos ao dispositivo:

  • Segurança elétrica: Ensure the device is connected to a properly grounded power outlet. Do not open the casing; não há peças que possam ser reparadas pelo usuário no interior. Encaminhe todos os serviços de manutenção para pessoal qualificado.
  • Conexão da bateria: Connect the battery with correct polarity (red to positive, black to negative). Incorrect connection can cause severe damage to the inverter and battery. Use a 12V DC battery with a capacity between 50-200 Ah (55 Ah suggested).
  • Ventilação: Ensure adequate ventilation around the unit. Do not block the fan or ventilation openings. Overheating can lead to device malfunction or damage.
  • Ambiente: Operate the device within the specified temperature range of 0 - 40°C and humidity of 10 - 90%. Avoid direct sunlight, moisture, dust, and corrosive environments.
  • Proteção contra sobrecarga: Do not exceed the rated power of 700 W. The device is equipped with overload protection, but continuous overloading can shorten its lifespan.
  • Contato com líquidos: Keep the device away from liquids. In case of accidental liquid contact, immediately disconnect power and consult a service technician.
  • Crianças e animais de estimação: Mantenha o dispositivo fora do alcance de crianças e animais de estimação.

3. Componentes do produto

Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

Frente view of Rebel POWER-1000 UPS Inverter showing the LED display and main power switch.

Figura 3.1: painel frontal
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

Traseira view of Rebel POWER-1000 UPS Inverter with battery cables, AC input, and output sockets.

Figura 3.2: Painel traseiro sobreview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.

Close-up of the rear panel connections on Rebel POWER-1000 UPS Inverter.

Figure 3.3: Rear Panel Connections Detail
Um mais próximo view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.

Componentes principais:

  • Telão LED: Provides real-time information on operating status, battery charge level, and load level.
  • Main ON/OFF Switch: Controls the power to the inverter.
  • Tomadas de saída CA: Two 230V AC sockets for connecting your devices.
  • Battery Terminals (12V DC): Connect to an external 12V DC battery. Ensure correct polarity.
  • AC Input (230V): Connects the inverter to the mains power supply for charging the battery and providing power in UPS mode.
  • Ventilador de resfriamento: Dissipa o calor gerado durante o funcionamento.
  • Disjuntor: Provides protection against overcurrent.

4. Configuração

Follow these steps to set up your Rebel POWER-1000 UPS Inverter:

  1. Desembalagem: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
  2. Colocação: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
  3. Conexão da bateria:
    • Certifique-se de que o inversor esteja DESLIGADO.
    • Conecte o vermelho cabo da bateria para o positivo (+) terminal of your 12V DC battery.
    • Conecte o preto cabo da bateria para o negativo (-) terminal of your 12V DC battery.
    • Tighten all connections securely to prevent arcing.
  4. Conexão de rede elétrica CA: Conecte o cabo de entrada CA do inversor a uma tomada de parede padrão de 230 V CA.
  5. Conexão do dispositivo: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.

5. Instruções de operação

The Rebel POWER-1000 operates in three main modes:

  • UPS Mode (Emergency Power Supply): When connected to mains power, the inverter charges the external battery and simultaneously supplies power to connected devices. In case of a power outage, it automatically switches to battery power within <4 ms, providing uninterrupted power.
  • Rectifier Mode (Battery Charger): When connected to mains power without any load, the inverter functions as a battery charger, replenishing the external battery.
  • Modo Inversor: When not connected to mains power, the inverter converts 12V DC battery power into 230V AC pure sine wave power for your connected devices.

Starting the Inverter:

  1. Ensure all connections (battery, AC input, loads) are secure.
  2. Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
  3. The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.

Informações do visor LED:

The clear LED display provides crucial information:

  • Vol de entradatage: Mostra a tensão CA de entrada.tage from the mains.
  • Volume de saídatage: Displays the 230V AC output voltage.
  • Bateria Voltage: Indica o vol atualtage da bateria de 12V conectada.
  • Nível de Carga: Mostra a porcentagemtage of the inverter's capacity being used by connected devices.
  • Situação Operacional: Icons or indicators for mains power, battery power, charging, and fault conditions.

6. Manutenção

A manutenção regular garante o desempenho ideal e a longevidade do seu inversor:

  • Limpeza: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure the cooling fan and ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Inspeção da bateria: Regularly check battery terminals for corrosion and ensure connections are tight. If using a lead-acid battery, check electrolyte levels if applicable and top up with distilled water as needed (refer to battery manufacturer's instructions).
  • Ventilação: Always ensure the inverter has adequate ventilation. Do not place objects on top of the unit or block its air vents.
  • Armazenar: If storing the inverter for an extended period, disconnect it from both mains power and the battery. Store in a cool, dry place. For optimal battery health, fully charge the battery before storage and recharge it every 3-6 months.

7. Solução De Problemas

If you encounter issues with your Rebel POWER-1000, refer to the following table:

ProblemaPossível causaSolução
O inversor não liga.No battery connected or battery discharged; Main switch off; Blown circuit breaker.Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel.
Sem saída CAOverload; Short circuit; Battery low; Inverter fault.Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support.
Bateria não carregaEntrada CA não conectada; volume de entrada CAtage too low/high; Battery fault.Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty.
Aviso de sobrecarga no visorTotal power of connected devices exceeds 700 W.Disconnect some devices to reduce the load below 700 W.
Unit is unusually hotVentilação obstruída; Carga excessiva; Temperatura ambiente elevada.Ensure vents are clear; Reduce load; Move unit to a cooler environment.

If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.

8. Especificações

Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):

RecursoEspecificação
Potência nominal700 W (1000 VA)
Tipo de Bateria12 V CC
Max Bateria Voltage15 V CC
Vol de entradatage Alcance190 - 260 V AC
Frequência de entrada45 - 60 Hz
Volume de saídatage (AC)230 V AC +/-5% (Inverter: 230 V AC +/-3%)
Frequência de saída50/60 Hz +/-0.5 Hz
Forma de onda de saídaPure Sine Wave
Eficiência de saída>= 85% (DC to AC)
Corrente de carregamento da bateriaMáx. 10 A
Capacidade sugerida da bateria50-200 Ah (suggested: 55 Ah)
Tempo estimado de carregamento4-14 hours (dependent on battery capacity)
Tempo de comutação=<4 ms
ProteçõesOverload, Short Circuit, Over/Under Voltage
Temperatura de operação0 - 40°C
Umidade operacional10 - 90%
Dimensões (C x L x A)336 x 143 x 178 mm
Peso4.3 kg

9. Garantia e Suporte

The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.

For technical support or service inquiries, please contact your local Rebel distributor or the point of purchase. Ensure you have your product model (RB-4003) and serial number (if applicable) ready when contacting support.

Ask a question about this manual