SPABOY ZJLCD-BT01
Manual do usuário
SPABOY ZJLCD-BT01 Turbine Flow Meter
Introdução
This manual provides detailed instructions for the installation, operation, and maintenance of the SPABOY ZJLCD-BT01 Turbine Flow Meter. Please read this manual thoroughly before using the device to ensure proper function and longevity.
The ZJLCD-BT01 is an electronic PVC LCD digital display flowmeter designed for accurate measurement of liquid flow, commonly used in farm and garden irrigation systems.
Produto acimaview

Figura 1: Frente view of the ZJLCD-BT01 Turbine Flow Meter, showing the LCD display, SET button, and CLEAR button.

Figura 2: Angulado view of the flow meter, highlighting the PVC pipe connections on both ends.

Figure 3: Close-up of the LCD display, showing the digital readout for flow measurement.

Figure 4: The LCD display indicating both instantaneous flow rate (top) and total accumulated flow (bottom).

Figure 5: The flow meter model without an external power cable, typically battery-powered.

Figure 6: The flow meter model with an external power cable for continuous power supply.
Especificações
| Recurso | Detalhe |
|---|---|
| Modelo | ZJLCD-BT01 |
| Marca | SPABOY |
| Tipo de exibição | Visor digital LCD |
| Volumetage | 5 Volts (CC) |
| Material | PVC |
| Tamanhos de tubos | 1", 1-1/2", 2", 2-1/2", 3" (depending on variant) |
| Aplicativo | Farm/Garden Irrigation, Industrial Flow Measurement |
Configuração e instalação
Proper installation is crucial for accurate readings and long-term performance. Follow these steps carefully:
- Escolha a localização: Select a section of pipe where the flow is stable and free from turbulence. Ensure there is sufficient straight pipe length before and after the meter (typically 10x diameter upstream and 5x diameter downstream).
- Preparar a tubulação: Turn off the water supply and drain the pipe section where the flow meter will be installed. Cut the pipe to the appropriate length to accommodate the flow meter.
- Install Meter: Insert the flow meter into the pipe, ensuring the flow direction arrow on the meter body aligns with the direction of water flow. Use appropriate PVC cement or threading tape for a watertight seal, depending on your pipe type and meter connections.
- Conexão de energia:
- Battery Powered Models: Ensure batteries are correctly inserted into the battery compartment.
- Modelos com fio: Connect the 5V DC power supply wires according to the color coding (typically red for positive, black for negative). Ensure connections are secure and insulated.
- Verificação de vazamento: Slowly restore water pressure to the system and check for any leaks around the flow meter connections. Tighten or re-seal as necessary.
Instruções de operação
The ZJLCD-BT01 features a simple interface for monitoring flow and total volume.
- Leitura do visor: The LCD screen typically displays the instantaneous flow rate (e.g., L/min, GPM) on the upper line and the total accumulated volume (e.g., Liters, Gallons) on the lower line.
- Botão de configuração: Pressione o DEFINIR button to cycle through different display modes or to enter calibration/setting mode (refer to advanced settings for calibration).
- Botão CLEAR: Pressione o CLARO button to reset the accumulated volume to zero. Hold the button for a few seconds to confirm the reset.
- Conversão de unidades: Some models may allow unit conversion (e.g., Liters to Gallons). Consult the specific model's advanced settings if this feature is available.
Manutenção
Regular maintenance ensures the accuracy and longevity of your flow meter.
- Limpeza: Periodically inspect the flow meter for any debris or sediment buildup, especially if used with unfiltered water. If necessary, remove the meter and gently clean the turbine impeller and internal passages.
- Substituição da bateria: For battery-powered models, replace batteries when the low battery indicator appears on the LCD, or if the display becomes dim. Use the recommended battery type (e.g., AAA, AA).
- Inspeção de vazamento: Regularly check all connections for leaks. Address any leaks promptly to prevent water damage and ensure accurate readings.
- Winterização: In freezing climates, ensure the flow meter is drained and protected from freezing temperatures to prevent damage to the PVC body and internal components.
Solução de problemas
| Problema | Possível causa | Solução |
|---|---|---|
| No display/Display is dim | Dead or low batteries (battery models); No power supply (wired models); Loose power connection. | Replace batteries; Check power supply and connections; Ensure proper voltage (5V CC). |
| Leituras imprecisas | Air in the line; Debris in the meter; Incorrect installation direction; Turbulence in flow. | Purge air from the system; Clean the meter; Verify flow direction arrow; Ensure sufficient straight pipe length. |
| Flow reading stuck at zero | No flow; Impeller jammed by debris; Sensor malfunction. | Verify water flow; Inspect and clean impeller; Contact support if issue persists. |
| Vazamentos nas conexões | Improper sealing; Damaged threads/gaskets. | Re-seal connections with appropriate sealant/tape; Replace damaged components. |
Garantia e Suporte
SPABOY products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official SPABOY website.
Guarde o comprovante de compra para reclamações de garantia.