This manual provides comprehensive instructions for the AUX DC Inverter Multi-Split Air Conditioner System, designed for efficient cooling and heating of multiple rooms. This system utilizes R-32 refrigerant and features advanced DC Inverter technology for optimal performance and energy savings. Please read this manual thoroughly before installation, operation, or maintenance to ensure correct usage and to prevent damage to the unit or injury to personnel.

2. Informações de segurança

Always adhere to the following safety precautions to prevent electric shock, fire, injury, or damage to the unit:

  • Installation must be performed by qualified and authorized personnel only, in accordance with national wiring regulations.
  • Certifique-se de que a fonte de alimentação corresponde às especificações da unidade.
  • Não tente reparar ou modificar a unidade por conta própria. Contate pessoal de serviço qualificado.
  • Garanta um aterramento adequado para evitar choque elétrico.
  • Do not block the air inlet or outlet of the indoor or outdoor units.
  • Mantenha as crianças afastadas do aparelho durante o funcionamento.
  • The refrigerant R-32 is mildly flammable. Handle with care and ensure proper ventilation during installation and servicing.

3. Conteúdo da embalagem

Upon unpacking, verify that all components are present and undamaged. The standard package for the AUX DC Inverter Multi-Split Air Conditioner System (Trial 12+12+12) typically includes:

  • One (1) Outdoor Unit (Model: AM4-H28/4DR3C)
  • Three (3) Indoor Units (e.g., 12000 BTU units, or a combination of 9000 BTU and 12000 BTU units as per your specific order)
  • Three (3) Remote Controls for Indoor Units
  • Manual do usuário e guia de instalação
  • Mounting accessories for indoor units

Note: Specific indoor unit models and quantities may vary based on the purchased configuration.

4. Especificações

The following table outlines the key technical specifications for the AUX DC Inverter Multi-Split Air Conditioner System:

RecursoEspecificação
MarcaAUX
Modelo de unidade externaAM4-H28/4DR3C
Cooling Capacity (Total)29650 BTU
Heating Capacity (Total)30776 BTU
Fonte de energiaSingle-phase 220-240V/1/50Hz
VIDENTE6.3
SCOP4.1
Classe de energiaA++A+
RefrigeranteR-32
Outdoor Unit Airflow3100 m³/h
Nível de pressão sonora da unidade externa56 dB
Operating Limit (Temperature)-35°C a +55°C
Dimensões da unidade externa (C x L x A)832 x 328 x 655 mm
Tamanho da linha de líquido1/4 de polegada
Gas Line Size3/8 de polegada
Comprimento máximo da linha70 metros
Maximum Single Line Length30 metros
Maximum Dislevel (Outdoor to Indoor)15 metros
Maximum Dislevel (Between Indoor Units)10 metros
Indoor Unit (9000 BTU) Cooling Capacity11260 BTU
Indoor Unit (9000 BTU) Heating Capacity11260 BTU
Indoor Unit (9000 BTU) Airflow800 m³/h
Indoor Unit (9000 BTU) Dimensions (LxWxH)792 x 200 x 285 mm
Indoor Unit (9000 BTU) Connections1/4 inch, 3/8 inch
Indoor Unit (9000 BTU) Drain Diameter16.5 milímetros
Indoor Unit (9000 BTU) Minimum Noise Level19 dB
Indoor Unit (12000 BTU) Cooling Capacity12625 BTU
Indoor Unit (12000 BTU) Heating Capacity12966 BTU
Indoor Unit (12000 BTU) Airflow600 m³/h
Indoor Unit (12000 BTU) Dimensions (LxWxH)750 x 200 x 285 mm
Indoor Unit (12000 BTU) Connections1/4 inch, 3/8 inch
Indoor Unit (12000 BTU) Drain Diameter16.5 milímetros
Indoor Unit (12000 BTU) Minimum Noise Level19 dB
Peso total120 kg
Tipo de controleControle remoto

5. Instalação

Installation of this multi-split air conditioning system requires specialized knowledge and tools. It must be performed by certified HVAC technicians.

5.1 Diretrizes Gerais

  • Seleção de local: Choose a location for the outdoor unit that allows for adequate airflow and is away from direct sunlight or heat sources. Indoor units should be placed to ensure even air distribution.
  • Montagem: Securely mount indoor and outdoor units according to the provided installation diagrams.
  • Tubulação de refrigerante: Connect the liquid and gas lines between the outdoor unit and each indoor unit. The system uses R-32 refrigerant, which operates at similar pressures to R410A. Ensure compatibility of tools (manifold gauge, leak detector, recovery unit) with R-32. R-32 is a pure gas, simplifying charging procedures compared to refrigerant mixtures.
  • Drenagem: Install condensate drain pipes with proper slope to ensure efficient water removal.
  • Fiação elétrica: Connect the power supply and communication cables according to the wiring diagram. Ensure all connections are secure and properly insulated.
  • Aspirar e carregar: Evacuate the system to remove non-condensable gases and moisture. Charge with the correct amount of R-32 refrigerant.

For detailed installation steps, refer to the separate Installation Manual provided with the product.

AUX DC Inverter Multi-Split Air Conditioner System outdoor unit.
Image showing the outdoor unit of the AUX DC Inverter Multi-Split Air Conditioner System. This unit connects to multiple indoor units for comprehensive climate control.

6. Operação

Your AUX air conditioner system is controlled via a wireless remote control. Familiarize yourself with the remote control functions for optimal use.

6.1 Operação básica

  • Ligar/desligar: Pressione o botão liga/desliga no controle remoto para ligar ou desligar a unidade.
  • Seleção de modo: Select desired operating mode (Cool, Heat, Fan, Dry, Auto) using the Mode button.
  • Ajuste de temperatura: Use the temperature up/down buttons to set the desired room temperature.
  • Velocidade do ventilador: Adjust fan speed (Auto, Low, Medium, High) to your preference.

6.2 Funções Avançadas

  • Temporizador 24H: This function allows you to set a specific time for the air conditioner to turn on or off within a 24-hour period.
  • Sinto que funciona: When activated, the remote control's built-in temperature sensor measures the ambient temperature and sends the data to the indoor unit, allowing the unit to adjust its operation for enhanced comfort around the remote control's location.
  • Super Resfriamento: Provides rapid cooling to quickly reach the desired temperature.
  • Função inteligente: Pressing the 'Smart' button on the remote control enables the air conditioner to operate in the most comfortable mode based on the current room temperature, automatically adjusting settings.
  • Função do sono: Optimizes temperature and fan speed settings during sleep for comfort and energy efficiency.
  • Controle por Wi-Fi (opcional): If equipped with the optional Wi-Fi module, the system can be controlled remotely via a smartphone application. Refer to the Wi-Fi module manual for setup instructions.

7. Características

The AUX DC Inverter Multi-Split Air Conditioner System incorporates several advanced features for superior performance and user experience:

  • Full DC Inverter Technology: Features a digital control signal, DC Inverter compressor, DC Inverter motors on both indoor and outdoor units, and an electronic expansion valve. This ensures low noise levels and high efficiency.
  • DC Inverter Twin Rotary Compressor: The newly designed BLDC Inverter twin rotary compressor provides improved balance and reduced vibrations, leading to maximum quietness and excellent efficiency and energy savings.
  • Electronic Expansion Valve: Precisely controls refrigerant flow for optimal system performance.
  • Volume baixotage Operação: The outdoor unit can operate within a wide voltage range (176V to 264V), ensuring stable performance even with voltage flutuações.
  • Auto-diagnosis and Automatic Protection: The system can detect operational anomalies and activate protective measures.
  • Aquecimento em baixa temperatura: Capable of providing effective heating even at outdoor temperatures as low as -15°C.
  • Auto degelo: Automatically defrosts the outdoor unit coil to maintain heating efficiency in cold conditions.
  • Reiniciar a 8°C: A function that maintains a minimum temperature of 8°C to prevent freezing in unoccupied rooms during winter.
  • Anti-mold Function: After the air conditioner is turned off, the indoor fan continues to operate for 30 seconds to dry any condensation inside the indoor unit, preventing mold formation.
  • Filtragem avançada: Includes an active carbon filter and a 4-in-1 filter system for improved air quality.
  • Rubidium Magnet Compressor: Enhances efficiency and reduces power consumption through increased gas molecule compression.
  • Optimized Heat Exchanger Design: The external heat exchanger is designed to maximize heat transfer, improving the refrigeration circuit's efficiency and preventing ice blockages. It also supports long-distance connections between units without reducing cooling capacity.

8. Manutenção

Regular maintenance ensures the longevity and efficient operation of your air conditioning system. Always turn off the power supply before performing any maintenance.

8.1 Manutenção da Unidade Interna

  • Limpeza do filtro: Clean the air filters every two weeks or more frequently depending on usage and air quality. Remove filters, wash with lukewarm water, dry thoroughly, and reinsert.
  • Limpeza da superfície da unidade: Limpe a superfície da unidade interna com um pano macio e seco.amp pano. Não utilize detergentes agressivos ou produtos de limpeza abrasivos.
  • Anti-mold Function: Utilize the built-in anti-mold function to keep the indoor coil dry.

8.2 Manutenção da Unidade Externa

  • Limpeza da bobina: Periodically check and clean the outdoor unit's coil to remove dust, leaves, and other debris that can obstruct airflow. This should ideally be done by a professional.
  • Obstruções claras: Certifique-se de que não haja obstruções ao redor da unidade externa que possam impedir o fluxo de ar.

8.3 Manutenção Profissional

It is recommended to have your system professionally serviced at least once a year by a qualified technician. This includes checking refrigerant levels, electrical connections, and overall system performance.

9. Solução De Problemas

Before contacting service personnel, review Os seguintes problemas comuns e suas possíveis soluções:

ProblemaPossível causaSolução
A unidade não ligaNo power supply; Remote control batteries low; Circuit breaker trippedVerifique a conexão de energia; Troque as pilhas; Reinicie o disjuntor.
Refrigeração/aquecimento insuficienteDirty air filters; Blocked outdoor unit; Incorrect mode/temperature setting; Low refrigerantClean filters; Clear obstructions; Adjust settings; Contact technician for refrigerant check
Ruído incomumPeças soltas; Obstrução do ventilador; Ruído do fluxo de refrigerante (normal)Check for loose parts; Clear obstructions; If persistent or loud, contact technician
Vazamento de água da unidade internaBlocked drain pipe; Improper installationClear drain pipe; Contact technician for inspection
Controle remoto não funcionaBatteries low/dead; Obstruction between remote and unitReplace batteries; Ensure clear line of sight

The system features an auto-diagnosis function. If an error code appears on the display, consult the detailed troubleshooting section in the full user manual or contact customer support with the error code.

10. Garantia e Suporte

Your AUX DC Inverter Multi-Split Air Conditioner System is covered by a manufacturer's warranty.

  • Garantia de fábrica: A 5-year factory warranty is provided for certain components.
  • Garantia do produto: A general 2-year product warranty applies.

Please refer to your purchase documentation for specific warranty terms and conditions, as these may vary by region and retailer. For warranty claims, technical support, or service requests, please contact your authorized dealer or the AUX customer service department.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.