Shimge BL(T)8-3-2.2

Calço BL(T)8-3-2.2 Vertical Multi-stage Manual do usuário da bomba centrífuga

Model: BL(T)8-3-2.2 | Brand: Shimge

1. Introdução

This user manual provides essential information for the safe and efficient operation, installation, and maintenance of the Shimge BL(T)8-3-2.2 Vertical Multi-stage Centrifugal Pump. Please read this manual thoroughly before operating the pump to ensure proper function and to prevent damage or injury.

The Shimge BL(T)8-3-2.2 is a high-efficiency, low-noise, and reliable stainless steel multi-stage centrifugal pump designed for continuous operation in various demanding applications. It is a non-self-priming vertical multi-stage structure pump.

2. Instruções de segurança

AVISO: O não cumprimento destas instruções de segurança pode resultar em ferimentos graves ou morte.

  • Desligue sempre a alimentação elétrica antes de realizar qualquer manutenção ou serviço na bomba.
  • Certifique-se de que a bomba esteja devidamente aterrada para evitar choque elétrico.
  • Do not operate the pump with damaged electrical cords or connections.
  • Mantenha as mãos e roupas largas longe das peças móveis.
  • Ensure the installation area is well-ventilated and free from flammable materials.
  • The pump is designed for specific fluid temperatures (36 °F to 155 °F) and ambient temperatures (5 °F to 104 °F). Operating outside these limits may cause damage.
  • Maintain a pH value of the medium between 5 and 9.
  • If the density or viscosity of the medium is higher than water, a more powerful pump should be used.

3. Produto acabadoview

The Shimge BL(T)8-3-2.2 pump is a robust and efficient solution for various water transfer and pressure boosting applications. Its design emphasizes durability and reliable performance.

3.1 Principais Características

  • Poder: 3 CV (2.2 kW)
  • Volumetage: 220V, 3-Phase, 60Hz
  • Material: Stainless steel impeller, Cast Iron body.
  • Classe de proteção: IP55
  • Classe de isolamento: F
  • Proteção térmica integrada: Sim
  • Conexões: Flange ANSI B16.5 Class 150 / 2" Pipe Size
  • Cabo de energia: Not included (requires separate wiring)

3.2 componentes do produto

Calço BL(T)8-3-2.2 Vertical Multi-stage Bomba Centrífuga

Figura 1: Overview of the Shimge BL(T)8-3-2.2 Vertical Multi-stage Centrifugal Pump. This image shows the main pump unit with its motor, pump head, and flange connections.

4. Configuração e instalação

Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a qualified professional.

4.1 Lista de verificação de pré-instalação

  • Verify power supply matches pump requirements (220V, 3-Phase, 60Hz).
  • Garanta espaço adequado para instalação, manutenção e ventilação.
  • Confirm pipe connections (2" Pipe Size, Flange ANSI B16.5 Class 150) are compatible.
  • Prepare a stable, level foundation capable of supporting the pump's weight (approx. 112 lbs / 50.8 kg).

4.2 Etapas de instalação

  1. Montagem: Securely bolt the pump to the prepared foundation, ensuring it is level to prevent vibration and stress on connections.
  2. Tubulação: Connect the inlet and outlet pipes to the pump's flanges. Use appropriate gaskets and ensure connections are leak-free. Avoid putting strain on the pump body from misaligned pipes.
  3. Fiação elétrica: Connect the pump to the 220V, 3-Phase power supply. Ensure all wiring complies with local electrical codes. Note that a power cable is not included with the pump and must be sourced separately. The pump has built-in thermal protection.
  4. Preparação: As this is a non-self-priming pump, ensure the pump and suction line are completely filled with the liquid to be pumped before starting.

5. Instruções de operação

Follow these steps for safe and effective operation of your Shimge pump.

5.1 Iniciando a Bomba

  1. Ensure the pump is properly primed (filled with liquid).
  2. Open any necessary valves on the suction and discharge lines.
  3. Turn on the power supply to the pump. The pump should start smoothly.
  4. Monitor the pump for unusual noises or vibrations during the initial startup.

5.2 Características de Desempenho

The pump's performance varies with flow rate and head. Refer to the performance curve for detailed operational parameters.

Performance Curve for Shimge BL(T)8-3-2.2 Pump

Figure 2: Performance Curve for the Shimge BL(T)8-3-2.2 Pump. This graph illustrates the relationship between flow rate (Q), head (H), power (P2), and efficiency (Eta) at 3500 RPM and 60Hz, crucial for understanding pump operation under various conditions.

Fluxo nominal: 35.2 gpm (8 m³/hr)
Faixa de fluxo: 30.8 - 57.2 Gpm
Rated Head: 40 metros
Alcance da cabeça: 41 a 30 metros

5.3 Desligando a Bomba

  1. Desligue a fonte de alimentação da bomba.
  2. Close any necessary valves on the suction and discharge lines.

6. Manutenção

Regular maintenance ensures the longevity and optimal performance of your pump. Always disconnect power before maintenance.

6.1 Verificações de Rotina

  • Diário: Check for any leaks around seals and connections. Listen for unusual noises or vibrations.
  • Semanalmente: Inspect electrical connections for signs of wear or corrosion. Ensure ventilation openings are clear.
  • Mensal: Verify mounting bolts are secure. Check the condition of the power cable.

6.2 Limpeza

Keep the exterior of the pump clean to prevent dust and debris buildup, which can affect cooling.

6.3 Armazenamento de Longo Prazo

If the pump will be out of service for an extended period, drain all liquid from the pump and pipes. Store in a dry, protected environment.

7. Solução De Problemas

Esta seção fornece soluções para problemas comuns. Para problemas não listados aqui, entre em contato com pessoal de serviço qualificado.

ProblemaPossível causaSolução
A bomba não iniciaNo power; tripped circuit breaker; motor overload; wiring issue.Check power supply; reset breaker; allow motor to cool; inspect wiring.
Low flow or no flowPump not primed; clogged suction line/filter; air in system; incorrect rotation.Prime pump; clear obstruction; bleed air; check motor rotation (for 3-phase).
Ruído excessivo ou vibraçãoCavitation; loose mounting; worn bearings; foreign object in pump.Ensure adequate suction pressure; tighten mounting bolts; contact service; inspect impeller.
Vazamentos da bombaLoose connections; damaged seals/gaskets.Tighten connections; replace seals/gaskets.

8. Especificações técnicas

ParâmetroValor
ModeloBL(T)8-3-2.2
MarcaShimge
Poder2.2 kW (3 HP)
Volumetage220V, 3-Phase, 60Hz
Atual8 Amps
RPM3,450
Fluxo nominal35.2 gpm (8 m³/hr)
Faixa de fluxo30.8 - 57.2 Gpm
Rated Head40 metros
Alcance da cabeça41 a 30 metros
Conexões de entrada/saídaFlange ANSI B16.5 Class 150 / 2" Pipe Size
Material do impulsorAço inoxidável
Material do corpoFerro fundido
Built-in Thermal ProtectionSim
Classe de proteçãoIP55
Classe de isolamentoF
Dimensões (CxLxA)11 x 6.6 x 27.2 polegadas (27.9 x 16.8 x 69.1 cm)
Peso112 libras (50.8 kg)
Faixa de temperatura média36 °F a 155 °F (2 °C a 68 °C)
Faixa de temperatura ambiente5 ° F a 104 ° F (-15 ° C a 40 ° C)
PH Value of Medium5 para 9
UPC792105746982

8.1 Aplicações

  • Aumento de pressão
  • Distribution from water works
  • Pressure boosting in mines
  • Pressure boosting in high-rise buildings
  • Hotéis
  • Process water systems
  • Sistemas de lavagem de veículos
  • Firefighters systems

9. Informações de garantia

The product description mentions "WARRANTY!". For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact Shimge customer support directly. Typically, warranties cover defects in materials and workmanship under normal use.

10. Suporte ao cliente

For technical assistance, spare parts, or service inquiries, please contact Shimge customer support. Refer to the product packaging or the official Shimge website para obter as informações de contato mais atualizadas.

Shimge Official Website: www.shimge.com

© 2025 Shimge. All rights reserved. This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.