VOLTCRAFT DOV704

Voltcraft DOV704 Digital Oscilloscope User Manual

Model: DOV704 | Brand: VOLTCRAFT

1. Introdução

This manual provides essential information for the safe and efficient operation of your Voltcraft DOV704 Digital Oscilloscope. The DOV704 is a high-quality, innovative, and compact 4-channel digital storage oscilloscope featuring a 70 MHz bandwidth, 1.25 GSa/s maximum sampling rate, and a 12-bit analog-to-digital converter. It is equipped with a 7-inch touchscreen display supporting gesture control, USB, LAN, and HDMI interfaces. Please read this manual thoroughly before using the device.

2. Informações de segurança

Observe sempre as seguintes precauções de segurança para evitar ferimentos e danos ao dispositivo:

  • Certifique-se de que a fonte de alimentação voltage atende aos requisitos especificados no dispositivo.
  • Do not operate the oscilloscope in wet or damp condições.
  • Evite expor o dispositivo à luz solar direta ou a temperaturas extremas.
  • Use apenas o adaptador de alimentação e os acessórios fornecidos.
  • Não tente abrir ou modificar o dispositivo. Encaminhe todos os serviços de manutenção a pessoal qualificado.
  • Antes de fazer qualquer conexão, certifique-se de que o dispositivo esteja desligado.

3. Conteúdo da embalagem

Verifique se todos os itens listados abaixo estão presentes em sua embalagem:

  • Voltcraft DOV704 Digital Oscilloscope
  • Adaptador de energia USB tipo C
  • Cabo USB
  • Four (4) Test Probes
  • Two (2) Probe Adjustment Kits
  • Software with English Manual (on CD)
  • Guia de início rápido
  • Ficha de dados do produto

4. Produto acabadoview

The Voltcraft DOV704 is designed for precise signal analysis. Below are key features and a visual representation of the device.

4.1 Principais Características

  • Largura de banda de 70 MHz
  • 4 Analog Input Channels
  • 7-inch (17.78 cm) Touchscreen Display with Gesture Control (1024 x 600 pixels)
  • 12-bit Analog-to-Digital Converter
  • S máximoampling Rate: 1.25 GSa/s
  • Real-time Waveform Capture Rate: 50,000 wfms/s
  • Segmented Waveform Capture Rate: 700,000 wfms/s
  • Record Length: 50 Mpts
  • Horizontal Scan Speed: 1 ns/div to 1000 s/div (1-2-5 steps)
  • Vertical Sensitivity: 500 µV/div to 10 V/div
  • Multiple Trigger Functions: Edge, Video, Pulse, Slope, Runt, Window, Timeout, Nth, Logic, RS232/UART, I2C, SPI, CAN, LIN
  • Connectivity: USB, LAN, HDMI

4.2 Layout do dispositivo

Voltcraft DOV704 Digital Oscilloscope front view com tela e controles

Figura 1: Frente view of the Voltcraft DOV704 Digital Oscilloscope, showing the 7-inch touchscreen display, control knobs, buttons, and four BNC input connectors at the bottom. The power button and USB ports are also visible.

Voltcraft DOV704 Digital Oscilloscope angled front view

Figura 2: Frente angulada view of the Voltcraft DOV704 Digital Oscilloscope, providing a clearer perspective of the control panel and input ports. The screen displays a waveform.

Voltcraft DOV704 Digital Oscilloscope side view

Figura 3: Lado view of the Voltcraft DOV704 Digital Oscilloscope, illustrating its compact profile e grelhas de ventilação.

5. Configuração

5.1 Ligando o dispositivo

  1. Connect the USB Type-C power adapter to the oscilloscope's power input port.
  2. Conecte o adaptador de alimentação a uma tomada elétrica adequada.
  3. Press the power button located on the front panel to turn on the oscilloscope. The display will illuminate.

5.2 Conexão e Compensação da Sonda

  1. Connect a test probe to one of the BNC input channels (CH1-CH4) on the front panel.
  2. Attach the probe tip to the probe compensation output (usually a square wave signal output on the front or side).
  3. Adjust the probe compensation screw (located on the probe body) until the square wave displayed on the screen has flat tops and bottoms, without overshoot or undershoot.
  4. Repeat this process for all probes you intend to use.

6. Instruções de operação

6.1 Basic Waveform Display

  • Seleção de canais: Press the CH1, CH2, CH3, or CH4 buttons to enable or disable a channel.
  • Vertical Scale: Use o Escala vertical knob to adjust the volts per division (V/div) for the selected channel.
  • Posição vertical: Use o Posição vertical knob to move the waveform up or down on the screen.
  • Horizontal Scale: Use o Escala horizontal knob to adjust the time per division (s/div).
  • Posição horizontal: Use o Posição horizontal knob to shift the waveform left or right.

6.2 Funções de disparo

The oscilloscope offers various trigger types to stabilize and capture specific parts of a waveform.

  • Pressione o Acionar botão para acessar as configurações do gatilho.
  • Select the desired trigger type (e.g., Edge, Pulse, Video) from the menu.
  • Adjust the trigger level using the dedicated Nível de desencadeamento knob or via the touchscreen.
  • Choose the trigger source (CH1-CH4) as needed.

6.3 Touchscreen and Gesture Control

The 7-inch touchscreen allows for intuitive control.

  • Tocar: Select menu items, buttons, or adjust settings.
  • Ampliar com os dedos: Use two fingers to zoom in or out on waveforms (horizontal and vertical scaling).
  • Arrastar: Move waveforms or menu elements across the screen.

6.4 Data Storage and Connectivity

The DOV704 supports various methods for data storage and external connectivity.

  • USB: Connect a USB flash drive to save waveform data, screenshots, or settings. Use the USB cable to connect to a computer for data transfer.
  • LAN: Connect the oscilloscope to a network for remote control and data access using the provided software.
  • HDMI: Connect an external display via the HDMI port for larger viewing of waveforms.

7. Manutenção

7.1 Limpeza

  • Desconecte a energia antes de limpar.
  • Use um pano macio e seco para limpar o exterior do dispositivo.
  • For the touchscreen, use a soft, lint-free cloth slightly dampened with a screen cleaner. Avoid abrasive cleaners.
  • Não permita que líquidos entrem no aparelho.

7.2 Armazenamento

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.

8. Solução De Problemas

ProblemaPossível causaSolução
O dispositivo não liga.Cabo de alimentação desconectado ou com defeito.Check power cable connection. Ensure power outlet is functional. Use the provided power adapter.
Nenhuma forma de onda exibida.Channel disabled, probe not connected, or signal too weak/strong.Ensure the desired channel is enabled. Check probe connection. Adjust vertical scale (V/div) and horizontal scale (s/div). Check trigger settings.
A forma de onda é instável.Configurações de gatilho incorretas.Adjust trigger level and trigger type. Ensure trigger source is correctly selected.
Tela sensível ao toque sem resposta.Falha temporária de software.Restart the device. If the problem persists, contact support.

9. Especificações

ParâmetroValor
Número do modeloVC-16753910
Largura de banda70 MHz
Canais Analógicos4
Máx. SampTaxa de ling1.25 GSa/s
Duração do registro50 Mpts
Resolução ADC12 bits
Waveform Capture Rate (Real-time)50,000 wfms/s
Waveform Capture Rate (Segmented)700,000 wfms/s
Mostrar7-inch Touchscreen (1024 x 600 pixels)
Horizontal Scan Speed1 ns/div to 1000 s/div
Sensibilidade Vertical500 µV/div a 10 V/div
InterfacesUSB, LAN, HDMI
Dimensões do produto (L x P x A)26 x 7.8 x 16 cm
Peso2.71 kg

10. Garantia e Suporte

For warranty information, please refer to the product data sheet included in your package or visit the official VOLTCRAFT website. For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact VOLTCRAFT customer service. Contact details can typically be found on the manufacturer's website ou na documentação fornecida com o seu produto.

© 2026 VOLTCRAFT. Todos os direitos reservados.