1. Introdução
This manual provides detailed instructions for the installation, operation, and maintenance of your Aninerel 3600W Hybrid Solar Inverter Charger, Model SPI4836M80-300P. This advanced inverter is designed to efficiently convert 48Vdc solar power to 110Vac for various applications, featuring a built-in 80A MPPT controller and pure sine wave output. It supports both battery-less operation and compatibility with AGM and Lithium battery systems.
2. Recursos do Produto
The Aninerel 3600W Hybrid Solar Inverter Charger offers a range of features for optimal performance and flexibility:
- Saída de alta potência: 3600W continuous power output.
- Volumetage Conversão: Converts 48Vdc to 110Vac.
- Controlador MPPT avançado: Integrated 80A MPPT (Maximum Power Point Tracking) solar charge controller for efficient solar energy harvesting, supporting up to 500Vdc maximum PV input.
- Saída de onda senoidal pura: Ensures compatibility and safe operation for all types of home appliances.
- Compatibilidade da bateria: Supports battery-less operation or connection with AGM, Lithium, and Flooded batteries. Includes Lithium Battery Communication (BMS).
- Conexão de rede: Designed for grid-tied systems with no feedback to the grid.
- Scalable Power: Capable of connecting up to six units in parallel for a total output of 21.6kW.
- Design versátil: Supports 120V/240V split-phase and 208V 3-phase configurations for various residential and commercial applications.
- Configurações flexíveis: Customizable charging profiles, alarms, and cut-off parameters.
- Monitoramento sem fio: Built-in Wi-Fi for remote monitoring of your system via a smartphone application.
- Conexão do gerador: Allows for integration with a generator for additional power input.
- Portas de comunicação: Includes RS485 for communication.
Figura 1: Overview of Aninerel 3600W Hybrid Inverter features, including battery compatibility, grid connection, scalable power, versatile design, flexible settings, and wireless communication.
3. Produto acabadoview e Componentes
Familiarize yourself with the main components and connection ports of the inverter:
Figure 2: Detailed diagram showing the various components and ports of the Aninerel Hybrid Solar Inverter.
- Luz indicadora: Provides status indications.
- Tela LCD: Displays operational data and settings.
- Teclado: Buttons for navigation and setting adjustments.
- Protetor de sobrecarga: Safety mechanism against excessive current.
- Grounding Screw Hold: Point for system grounding.
- Porta de saída CA: Conecta-se às cargas domésticas.
- WiFi Port (Optional): For wireless monitoring module connection.
- Porta de entrada CA: Conecta-se à rede elétrica ou a um gerador de energia CA.
- RS485-2 Communication Port: For external communication.
- RS485-1 Communication Port: For external communication.
- Porta de comunicação USB: Para transferência de dados ou atualizações de firmware.
- Ventilador de resfriamento: Dissipa calor durante a operação.
- ON/OFF Rocker Switch: Interruptor principal de alimentação do inversor.
- Porta de contato seco: Para sinais de controle externos.
- Current Sharing Port (Parallel Module Only): Para operação paralela.
- Parallel Communication Port (Parallel Module Only): Para operação paralela.
- Porta da bateria: Conecta-se ao banco de baterias.
- Porta fotovoltaica: Connects to solar panel arrays.
4. Configuração e instalação
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these steps carefully.
4.1. Guia de fiação
This video demonstrates the basic wiring procedure for the inverter, including connecting AC output and battery terminals.
Video 1: This video demonstrates general wiring steps for an Aninerel Solar Inverter, including connecting AC output and battery terminals. While the video features a 3KW 24V model, the wiring principles are similar for the 3600W 48Vdc inverter.
- Remove Port Cover: Carefully remove the bottom port cover of the inverter to access the wiring terminals.
- Conecte a saída CA: Connect the Live (L) and Neutral (N) wires of your main AC output to the designated terminals.
- Conecte a bateria: Connect the positive and negative terminals of your battery bank to the corresponding battery ports on the inverter. Ensure correct polarity.
- Reinstall Port Cover: Once all connections are secure, reinstall the port cover.
Importante: Always ensure the inverter is powered off before making any electrical connections. Consult a qualified electrician if you are unsure about any wiring procedures.
4.2. Compatibilidade da bateria
The inverter is compatible with various battery types, including Lead-Acid (AGM, GEL, Flooded) and Lithium batteries. For Lithium batteries, the inverter supports communication with Battery Management Systems (BMS) for optimized charging and discharge.
Figure 3: Illustration showing the inverter's compatibility with various 48V battery types, including GEL, FLD (Flooded), LI (Lithium), and SLD (Sealed Lead-Acid).
4.3. Conexão paralela
For increased power output, multiple inverters can be connected in parallel. The system supports up to six units for a maximum of 21.6kW power delivery in 120V residential systems. It also supports split-phase and 3-phase configurations.
Figure 4: Diagrams illustrating single-phase and split-phase parallel connection options for the Aninerel Hybrid Inverter, showing how to combine multiple units for higher power output.
5. Instruções de operação
5.1. Charging Priority Settings
The inverter allows you to configure how the battery bank is charged from different power sources. You can select from the following priorities:
- Prioridade à energia solar: The inverter prioritizes solar power for charging. AC input will only charge the battery when solar power is no longer available.
- Solar and AC Input: The inverter charges the battery bank from both solar and AC power simultaneously.
- Somente Solar: The inverter will only charge the battery bank from available solar power.
5.2. Load Priority Settings
Control how your appliances are powered to ensure continuous operation. Options include:
- Prioridade à energia solar: The inverter uses solar power first. If solar is insufficient, it will compensate with AC input.
- AC Priority: The inverter uses AC input to power all loads. DC input is used only if AC input is unavailable.
- DC Priority: The inverter prioritizes inverting from solar first. If solar is not enough, it will convert from battery power and will only power loads from AC input once the low battery warning triggers.
Figure 5: Visual guide to setting charging and load priorities on the Aninerel Hybrid Inverter, explaining Solar Priority, Solar and AC Input, Solar Only, AC Priority, and DC Priority modes.
5.3. Wi-Fi Monitoring
The inverter includes a built-in Wi-Fi module, allowing you to monitor its status and performance remotely via a smartphone application. Registration may be required to use the monitoring features.
Figure 6: Diagram illustrating the Wi-Fi module connection and remote monitoring capabilities of the Aninerel Hybrid Inverter via a smartphone app.
6. Manutenção
Regular maintenance ensures the longevity and optimal performance of your Aninerel Hybrid Solar Inverter. Always disconnect all power sources (solar, battery, AC input) before performing any maintenance.
- Limpeza: Keep the inverter's exterior clean and free from dust and debris. Use a dry, soft cloth. Do not use liquid cleaners.
- Ventilação: Ensure that the cooling fans and ventilation openings are not blocked. Proper airflow is essential to prevent overheating.
- Conexões: Periodically check all electrical connections for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
- Inspeção da bateria: If using batteries, regularly inspect them for any signs of damage, leakage, or swelling. Ensure battery terminals are clean and secure.
- Atualizações de firmware: Verifique o fabricante website or the monitoring app for any available firmware updates to ensure your inverter has the latest features and bug fixes.
7. Solução De Problemas
Esta seção fornece soluções para problemas comuns que você pode encontrar com seu inversor. Para problemas não listados aqui, entre em contato com o suporte ao cliente.
| Problema | Possível causa | Solução |
|---|---|---|
| O inversor não liga. | No DC input from battery/solar; Main switch off; Loose connections. | Verifique o volume da bateriatage and solar input. Ensure the ON/OFF switch is in the 'ON' position. Verify all wiring connections are secure. |
| Sem saída CA | Sobrecarga; Curto-circuito; Falha no inversor; Disjuntor de saída CA desarmado. | Reduce load. Check for short circuits in the AC wiring. Reset AC output breaker. Check LCD for error codes. |
| Bateria fraca voltage alarme | Insufficient charging; Excessive load; Battery degradation. | Check solar panel output and connections. Reduce load. Consider battery health and replacement if necessary. Adjust charging priority. |
| Alarme de superaquecimento | Blocked ventilation; High ambient temperature; Excessive load. | Ensure clear airflow around the inverter. Reduce ambient temperature if possible. Decrease the connected load. |
| Wi-Fi monitoring not working | Wi-Fi module not connected; Network issues; App not configured. | Ensure the Wi-Fi module is securely connected. Check your local Wi-Fi network. Reconfigure the monitoring app settings. |
8. Especificações
Key technical specifications for the Aninerel 3600W Hybrid Solar Inverter Charger:
| Atributo | Valor |
|---|---|
| Número do modelo | SPI4836M80-300P |
| Marca | Aninerel |
| O quetage | 3600 watts |
| Volumetage | 48 Volts (DC input) |
| Vol de saída ACtage | 110 Vac |
| Controlador MPPT de corrente | 80A (Built-in) |
| Vol. Máx. De Entrada PVtage | 500 Vdc |
| Fonte de energia | Energia solar e de bateria |
| Dimensões do produto (C x L x A) | 29.5L x 10W x 38.5H Centimetres (29.49 x 10.01 x 38.51 cm) |
| Peso do item | 9.18 kg |
| Fabricante | Shenzhen Anenji Energy Technology Co.,Ltd |
| ASIN | B0FLX9RHDG |
| Código UPC/GTIN | 757577193368 |
9. Acessórios de produto
The following accessories are typically included with your Aninerel 3600W Hybrid Solar Inverter Charger:
Figure 7: Image displaying the standard accessories included with the inverter, such as the instruction manual, installation toolkit, current sharing detection line, parallel cable, anti-reverse current CT, and WiFi module.
- Manual de instruções (x1)
- Installation Toolkit (x1)
- Current Sharing Detection Line (x1)
- Parallel Cable (x1)
- Anti-reverse Current CT (x1)
- WiFi Module (x1)
10. Product Application Scenarios
The Aninerel 3600W Hybrid Solar Inverter is versatile and suitable for a wide range of applications, including:
Figura 8: Examples of where the Aninerel Hybrid Inverter can be used, such as Solar Home Systems, Solar RV Systems, Solar Street Light Systems, Solar Power Plant Systems, Solar Vessels (Boat) Systems, and Hybrid Energy Systems.
- Sistemas solares residenciais
- Solar RV Systems
- Solar Street Light Systems
- Solar Power Plant Systems
- Solar Vessels (Boat) Systems
- Hybrid Energy Systems
11. Garantia e Suporte