Aninerel ANJ-12KP-SP-WIFI

Aninerel ANJ-12KP-SP-WIFI 12000W Solar Hybrid Inverter User Manual

Model: ANJ-12KP-SP-WIFI

Brand: Aninerel

1. Produto acabadoview

The Aninerel ANJ-12KP-SP-WIFI is a 12000W solar hybrid inverter designed for both on-grid and off-grid solar power systems. It converts 48V DC power to 120V single-phase or 240V split-phase AC power, providing a continuous output of 12,000W and a peak output of 24,000W. This inverter features two built-in MPPT solar charging controllers, supporting up to 6,000W + 6,000W PV input with a maximum DC voltage of 500V and a maximum PV charging current of 220A. It is suitable for various applications including RVs, homes, cabins, and workshops.

Aninerel ANJ-12KP-SP-WIFI 12000W Solar Hybrid Inverter

Imagem 1.1: Frente view of the Aninerel ANJ-12KP-SP-WIFI 12000W Solar Hybrid Inverter, showing the display screen and indicator lights.

Aninerel Single-Phase Hybrid Inverter System Diagram

Image 1.2: Diagram illustrating a typical single-phase hybrid inverter system setup, showing power flow from solar panels, grid, and battery to household loads.

2. Principais características

  • Saída de alta potência: 12,000W continuous, 24,000W peak output, 48V DC to 120V/240V AC split-phase conversion.
  • Dual MPPT Solar Charging: Two built-in MPPT controllers support up to 6,000W + 6,000W PV input with a maximum DC voltage of 500V and a maximum PV charging current of 220A.
  • Capacidade Paralela: Supports parallel connection of up to 6 units for a maximum output power of 72kW. Can achieve 120V single-phase, 240V split-phase, or 208V three-phase output with appropriate configurations.
  • Smart LCD Monitoring: Features an LCD screen and indicator LEDs for real-time monitoring of power input/output, battery status, and system alerts. Allows configuration of charging current, voltage thresholds, and priority modes.
  • Flexible Charging & Output Modes: Four charging modes (Solar Only, AC Priority, Solar Priority, Hybrid Charging) and three output modes (Mains Priority, PV Priority, Inverter Output) for diverse scenarios.
  • Compatibilidade da bateria: Compatible with AGM, GEL, Lead-acid, Li-ion, and LiFePO4 48V batteries. Supports no-battery mode for direct solar-to-load applications.
  • Design robusto: IP65-rated enclosure for dustproof and durable operation in various environments. Features intelligent cooling with a variable speed fan.
  • Proteções abrangentes: Proteções integradas contra overvoltage, subvoltage, reverse polarity, and short circuits.
Aninerel Hybrid Solar Inverter Features

Imagem 2.1: Terminadoview of key features including battery compatibility, grid connection, scalability, versatile design, flexible settings, and wireless communication.

3. Componentes e acessórios do produto

The following items are typically included with your Aninerel ANJ-12KP-SP-WIFI Hybrid Solar Inverter:

  • Aninerel ANJ-12KP-SP-WIFI Hybrid Solar Inverter Unit
  • Manual de instruções
  • Kit de ferramentas de instalação
  • Parallel Cable (x1)
  • Anti-reverse current CT (x2)
  • WiFi Module (x1)
Aninerel Hybrid Solar Inverter Product Accessories

Image 3.1: Contents of the product package, including the inverter, manual, installation tools, cables, CTs, and WiFi module.

4. Configuração e instalação

4.1. Instalação Física

Ensure the inverter is mounted in a well-ventilated area, protected from direct sunlight and moisture. The IP65 rating allows for indoor or semi-outdoor use. Refer to the included instruction manual for detailed mounting procedures and clearances.

4.2. Connection Ports Overview

Familiarize yourself with the various connection ports on the inverter. Proper connection is crucial for safe and efficient operation.

Aninerel Hybrid Solar Inverter Connection Ports

Imagem 4.1: Detalhada view of the inverter's connection panel, labeling each port for display, pilot lamp, AC output, AC input, WiFi port, USB, communication ports (RS485-1, RS485-2/CAN), dry contact, CT sensing, ON/OFF switch, PV parameters, battery parameters, parallel communication, AC input breaker, and grounding screw hold.

  1. Tela de exibição
  2. Piloto lamp
  3. Porta de saída AC
  4. Porta de entrada AC
  5. WiFi port (optional)
  6. Porta de comunicação USB
  7. Porta de comunicação RS485-1
  8. Porta de comunicação RS485-2/CAN
  9. Porta de contato seco
  10. CT sensing for self-consumption (optional)
  11. Interruptor basculante ON/OFF
  12. Parâmetros fotovoltaicos (PV)
  13. Parâmetros da bateria
  14. Porta de comunicação paralela (somente módulo paralelo)
  15. Disjuntor de entrada CA
  16. Fixação do parafuso de aterramento

4.3. Conexões elétricas

All electrical wiring should be performed by a qualified electrician in accordance with local electrical codes and regulations.

  • Entrada fotovoltaica: Connect your solar panel arrays to the PV input terminals. The inverter supports dual MPPT inputs, each up to 6000W. Ensure the PV array voltage está dentro da faixa especificada (90-450 VCC).
  • Conexão da bateria: Connect a 48V battery bank (AGM, GEL, Lead-acid, Li-ion, or LiFePO4) to the battery terminals. Observe correct polarity.
  • AC Input (Utility/Generator): Connect the grid or a generator to the AC input port.
  • Saída AC: Connect your household loads to the AC output port. The inverter provides 120V (L1/N, L2/N) or 240V (L1/L2) split-phase output.
  • Aterramento: Ensure the inverter is properly grounded using the grounding screw hold.
Aninerel Hybrid Solar Inverter Wiring Diagram

Image 4.2: Detailed wiring diagram showing connections for PV input, utility/generator input, battery, and inverter output to household loads.

4.4. Conexão paralela

The inverter supports parallel connection of up to 6 units to increase total power output and surge capacity. This allows for flexible configurations including single-phase, split-phase, or three-phase systems.

Aninerel Hybrid Solar Inverter Versatile Design Parallel Connection

Image 4.3: Diagrams illustrating various parallel connection configurations for single-phase and split-phase systems, showing how multiple inverters can be combined.

Aninerel Hybrid Solar Inverter Max 6 Parallel Connection

Image 4.4: Illustration of maximum 6 parallel connections for 120V single-phase/240V split-phase residential systems, delivering up to 72kW of power.

4.5. WiFi Monitoring Setup

The inverter includes a WiFi module for real-time monitoring of its operating status via a mobile application. Install the WiFi module into the designated port. Download the "Smart Value" app from the Google Play Store or Apple App Store to configure and monitor your system.

Aninerel Hybrid Solar Inverter WiFi Monitoring Setup

Image 4.5: Diagram showing the WiFi module connection to the inverter and a user monitoring the system via a smartphone app. The app "Smart Value" is available on Google Play and the App Store.

For detailed instructions on connecting the WiFi module and setting up the monitoring application, refer to the specific instructions provided with the WiFi module or contact customer support.

5. Instruções de operação

5.1. LCD Screen and Indicator LEDs

The inverter features an LCD screen and indicator LEDs to provide real-time status updates. The LCD allows for configuration of various system settings.

  • LED de saída CA: Indicates AC output status.
  • LED DE CARGA: Indica o estado de carregamento da bateria.
  • LED DE FALHA: Indicates system errors or faults.

Use the control buttons adjacent to the LCD screen to navigate menus and adjust settings such as charging current, voltage thresholds, and operational priority modes.

5.2. Charging Priority Modes

The inverter offers four charging modes to control how the battery bank is charged from different power sources:

  • Prioridade à energia solar: The inverter prioritizes solar power for charging. AC input will only charge the battery when solar power is insufficient.
  • Solar and AC Input: The inverter charges the battery bank from both solar and AC power simultaneously.
  • Somente Solar: The inverter charges the battery bank exclusively from available solar power.
  • Carregamento híbrido: (Details typically configured via settings, balancing solar and AC based on battery level and load).
Aninerel Hybrid Solar Inverter Charging and Load Priority Settings

Image 5.1: Diagrams illustrating the different charging priority modes (Solar Priority, Solar and AC input, Solar Only) and load priority modes (Solar Priority, AC Priority, DC Priority).

5.3. Output Priority Modes

The inverter provides three output modes to manage how appliances are powered:

  • Mains Priority (AC Priority): The inverter will redirect AC input to power all loads. If AC input is not available, it will switch to inverter output from batteries/solar.
  • PV Priority (Solar Priority): The inverter will use solar power to supply the load first. If solar power is insufficient, it will draw from AC input or batteries.
  • Inverter Output (DC Priority): The inverter prioritizes drawing power from the battery. If the battery level is low, it will switch to AC input.

5.4. No-Battery Operation

The inverter supports operation without a connected battery bank for direct solar-to-load applications. In this mode, the inverter will directly power loads from solar PV input. Ensure proper configuration for this mode as per the detailed manual.

6. Manutenção

Regular maintenance helps ensure the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

  • Limpeza: Limpe periodicamente a parte externa do inversor com um pano seco. Certifique-se de que as aberturas de ventilação estejam livres de poeira e detritos.
  • Conexões: Verifique anualmente todas as conexões elétricas para garantir que estejam bem apertadas e apresentem sinais de corrosão.
  • Saúde da bateria: If using a battery bank, monitor battery health and perform maintenance as recommended by the battery manufacturer.
  • Atualizações de firmware: Verifique o fabricante website or app for any available firmware updates for the inverter or WiFi module.

7. Solução De Problemas

This section provides general guidance for common issues. For detailed troubleshooting, refer to the complete instruction manual or contact technical support.

ProblemaPossível causaSolução
O inversor não liga.Sem entrada CC da bateria/painel fotovoltaico; disjuntor de entrada CA desarmado; interruptor liga/desliga desligado.Verifique as conexões da bateria e voltage; certifique-se de que a entrada fotovoltaica seja suficiente; reinicie o disjuntor de entrada CA; ligue a chave liga/desliga.
Sem saída CAOverload; battery low; fault condition; output mode setting.Reduce load; check battery charge; check fault codes on LCD; verify output mode settings.
Bateria não carregaPV input insufficient; charging mode setting; battery fault.Check solar panel connections and sunlight; verify charging mode (e.g., Solar Only); inspect battery health.
O monitoramento de Wi-Fi não está funcionando.WiFi module not installed correctly; network issues; app configuration.Ensure WiFi module is securely connected; check local WiFi network; reconfigure app settings.
Aninerel Hybrid Solar Inverter Built-in Protections

Image 7.1: Diagram illustrating the various built-in protections of the inverter, including overcharge, overload, overcurrent, overvoltage, short circuit, overheat, overspeed, and undervoltage proteção.

8. Especificações

Detailed technical specifications for the Aninerel ANJ-12KP-SP-WIFI Hybrid Solar Inverter.

ParâmetroValor
ModeloANJ-12KP-SP-WIFI
Potência de saída nominalSplit phase 12000VA/12000W (Single phase: 7200VA/7200W limited by wiring terminals)
Potência Máxima de PicoSplit phase 18000VA, Single phase 18000VA
Vol. Nominal de saídatage120Vac (L1/N, L2/N)/240Vac (L1/L2)
Capacidade de carga dos motores6 HP
Frequência AC nominal50Hz/60Hz
Capacidade paralela1~6 units
Volume de saídatage forma de ondaOnda senoidal pura
Proteção contra sobrecarga(102%<load<125%) +10% report error, turn off output after 5 minutes; (125%<load<150%) +10% report error, turn off output after 10 seconds; load>150% +10% report error, turn off output after 5 seconds.
Tipo de BateriaLithium/Lead-acid batteries
Vol. nominal da bateriatage51.2V (vol mínimo de partidatage 44V)
Mains/Generator Input Range(90Vac ~ 140Vac) ± 2%
Certificação de SegurançaUL STD.1741
Máx. Corrente de carregamento MPPT160A
Max. Mains/Generator Charging Current160A
Max. Hybrid Charge Current220A
Núm. de rastreadores MPP2
Máx. energia do painel fotovoltaico6000 W × 2
Corrente de entrada máx.22A × 2
Máx. Voltage de Circuito Aberto500 Vcc
Volume MPPTtage Alcance90 Vcc ~ 500 Vcc
Max. Bypass Phase Overload Current2P, 63A/63A (L1/L2)
Eficiência de rastreamento MPPT95%
Support CommunicationWiFi Modules/RS485/CAN/USB/Dry contact
Dimensões24.39 x 17.72 x 5.19 polegadas (61.95 x 45.01 x 13.18 cm)
Peso62.9 libras (28.53 kg)
Aninerel Hybrid Solar Inverter Detailed Specifications Table

Image 8.1: A table summarizing the detailed technical specifications of the ANJ-12000W-LVP-WIFI model.

9. Informações de suporte e contato

For technical assistance, warranty inquiries, or further information, please contact Aninerel customer support.

Aninerel Customer Support Contact Information

Image 9.1: Contact details for Aninerel customer support, including email, phone number, and operating hours.

© 2025 Aninerel. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.