Wiltec 65829 (18600 L/h)

Wiltec Pool Pump 18600 L/h User Manual

Model: 65829 (18600 L/h) | Brand: Wiltec

1. Introdução

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Wiltec Pool Pump, model 65829. This pump is designed for circulating and filtering water in pools ranging from 74 to 110 cubic meters, offering a high flow rate of 18,600 liters per hour and a maximum head of 13 meters. It is compatible with sand filter systems and features an integrated pre-filter for enhanced protection.

Wiltec Pool Pump 18600 L/h installed next to a swimming pool

Figura 1: Wiltec Pool Pump 18600 L/h in a typical pool setup. This image shows the pump connected to a pool system, highlighting its compact design and connection points.

2. Informações de segurança

Read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.

  • Desligue sempre a bomba da fonte de alimentação antes de realizar qualquer manutenção ou limpeza.
  • Ensure the electrical installation complies with local regulations and is protected by a Residual Current Device (RCD) with a tripping current not exceeding 30 mA.
  • Não utilize a bomba se o cabo de alimentação ou a ficha estiverem danificados.
  • The pump must be installed on a stable, level surface, protected from direct sunlight and adverse weather conditions.
  • Ensure adequate ventilation around the pump motor to prevent overheating.
  • This pump is designed for fresh water only, with a liquid temperature range of 0-35°C. Do not use with corrosive, flammable, or explosive liquids.

For detailed safety guidelines, please refer to the official Safety Information PDF document: Informações de segurança (PDF)

3. Componentes e dimensões do produto

The Wiltec Pool Pump consists of a robust motor, a pump housing with an integrated pre-filter, and inlet/outlet connections. Understanding the dimensions is crucial for proper installation and space planning.

Technical drawing showing the dimensions of the Wiltec Pool Pump

Figura 2: Product Dimensions. This diagram illustrates the pump's overall length (580 mm), width (242 mm), and height (367 mm), along with specific measurements for connections and components.

Os principais componentes incluem:

  • Pre-filter Basket: Located at the inlet, designed to capture debris larger than 3.9 mm.
  • Motor: 750W copper-wound motor with thermal overload protection.
  • Carcaça da bomba: Construção em plástico durável.
  • Entrada / Saída: Standard connections for pool hoses.

4. Configuração e instalação

Proper installation is vital for the pump's performance and longevity. It is recommended that installation be performed by a qualified technician.

  1. Colocação: Position the pump on a firm, level surface as close to the pool as possible to minimize suction lift. Ensure it is below the water level if possible for self-priming.
  2. Montagem: Secure the pump to the surface using appropriate fasteners to prevent vibration and movement.
  3. Conexões de encanamento: Connect the pump's inlet to the pool skimmer/main drain line and the outlet to the sand filter and return lines. Ensure all connections are watertight using thread sealant tape or appropriate gaskets.
  4. Conexão elétrica: Connect the pump to a dedicated, properly grounded electrical circuit protected by an RCD. Verify that the power supply voltage matches the pump's requirements (230V, 50Hz).
  5. Preparação: Before first use, fill the pre-filter housing with water to ensure the pump is primed. This prevents dry running and potential damage.

5. Instruções de operação

Após a instalação e o escorva, a bomba está pronta para funcionar.

  1. Iniciando a bomba: Ensure all valves are open and the pre-filter is full of water. Connect the pump to the power supply. The pump will start circulating water.
  2. Monitoramento de desempenho: Observe the water flow and pressure gauge (if installed on your filter system) to ensure optimal operation. The pump is designed for a maximum flow rate of 18,600 L/h and a maximum head of 13 meters.
  3. Faixa de temperatura: The pump is designed to operate with liquid temperatures between 0°C and 35°C. Operating outside this range may damage the pump.
  4. Parando a bomba: Disconnect the pump from the power supply. Close any necessary valves to prevent water backflow.
Diagram showing optimal flow rate and head for the Wiltec Pool Pump

Figura 3: Optimal Performance. This image highlights the pump's maximum head of 13 meters and maximum flow rate of 18,600 L/h, along with the recommended liquid temperature range of 0-35°C.

6. Manutenção

Regular maintenance ensures the longevity and efficient operation of your pool pump.

  • Limpeza do pré-filtro: The integrated pre-filter collects debris such as leaves, twigs, gravel, and hair. Regularly inspect and clean the pre-filter basket to maintain optimal flow and prevent pump strain. To clean, disconnect power, open the pre-filter lid, remove the basket, empty debris, and rinse thoroughly. Reassemble, ensuring the O-ring is properly seated and the lid is securely tightened.
  • Image showing the pre-filter of the Wiltec Pool Pump collecting debris

    Figura 4: Pre-filter Function. This image demonstrates how the pump's pre-filter effectively captures various types of debris, such as leaves, twigs, gravel, and hair, protecting the pump's internal components.

  • Inspeção do motor: Periodically check the motor for any unusual noises or excessive heat. The copper-wound motor is designed for stable operation and includes thermal overload protection.
  • Fraque view of the Wiltec Pool Pump motor showing copper windings

    Figura 5: Robust Motor Design. This image provides a view of the pump's copper-wound motor, emphasizing its stable operation and built-in protection against overheating and overload.

  • Limpeza geral: Mantenha a parte externa da bomba limpa e livre de sujeira e detritos.
  • Winterização: In regions with freezing temperatures, drain the pump completely and store it in a dry, frost-free location during the off-season to prevent damage.

7. Solução De Problemas

Se você tiver problemas com sua bomba, consulte os problemas comuns e suas soluções a seguir:

ProblemaPossível causaSolução
A bomba não iniciaNo power; tripped circuit breaker; motor overload protection activatedCheck power supply and connections; reset circuit breaker; allow motor to cool down if overheated.
Baixo fluxo de águaClogged pre-filter basket; air leak in suction line; low water level in pool; clogged impellerClean pre-filter basket; check all suction line connections for leaks; ensure adequate pool water level; inspect impeller for blockages.
A bomba funciona, mas não sai água.Pump not primed; air lock; closed valve in suction linePrime the pump by filling the pre-filter with water; check for and release air locks; ensure all valves are open.
Ruído ou vibração incomumAir in system; debris in impeller; loose mountingCheck for air leaks and prime pump; clean impeller; tighten mounting bolts.

If problems persist after attempting these solutions, contact a qualified service technician or Wiltec customer support.

8. Especificações

EspecificaçãoValor
FabricanteWiltec
Número do modelo65829
Flow Rate (Max)18,600 L/h
O quetage750 W
Cabeça Máxima13 metros
Volume de piscina recomendado74-110 m³
Dimensões do produto (C x L x A)58 x 24.7 x 36.7 cm
Peso do item10.25 kg
MaterialPlástico
CorAzul, Preto
Tipo de energiaCorded
Faixa de temperatura do líquido0-35°C

9. Garantia e Suporte

Para informações sobre garantia, suporte técnico ou assistência, entre em contato com o revendedor ou o fabricante diretamente. Guarde o comprovante de compra como prova de aquisição.

A Certificate of Conformity is available for this product: Certificate of Conformity (PDF)

© 2026 Wiltec. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.