Henry CVC370-2

NUMATIC Charles CVC370 240V Vacuum Cleaner User Manual

Model: CVC370-2 | Brand: Henry

1. Introdução

The NUMATIC Charles CVC370 is a versatile wet and dry vacuum cleaner designed for robust cleaning tasks in various environments. Equipped with a powerful 1200W motor, Charles is built to handle both dry debris and liquid spills with ease. Its adaptable design allows for quick transitions between wet and dry pick-up modes, making it suitable for hard floors, carpets, upholstery, and emergency clean-ups like blocked sinks or household leaks. The self-seal tab on the dust bags ensures a clean and dust-free emptying process after dry use.

NUMATIC Charles CVC370 240V Vacuum Cleaner

Figure 1: The Charles CVC370 240V Vacuum Cleaner with hose and floor tool attached.

2. Informações importantes de segurança

Leia atentamente todas as instruções antes de usar o aparelho. O não cumprimento destas instruções pode resultar em choque elétrico, incêndio ou ferimentos graves.

  • Certifique-se sempre de que a fonte de alimentação seja compatível com a voltagem.tage especificado na etiqueta de classificação.
  • Do not use the appliance outdoors or on wet surfaces when operating in dry mode.
  • Unplug from the mains supply before cleaning or performing maintenance.
  • Do not pick up flammable or combustible materials, hot ashes, or large sharp objects.
  • Mantenha cabelos, roupas largas, dedos e todas as partes do corpo longe de aberturas e peças móveis.
  • When wet vacuuming, ensure the dry filter and dust bag are removed.
  • Não mergulhe o aparelho em água.
  • Este aparelho não se destina ao uso por pessoas (incluindo crianças) com capacidades físicas, sensoriais ou mentais reduzidas, ou com falta de experiência e conhecimento, a menos que tenham recebido supervisão ou instruções sobre o uso do aparelho de uma pessoa responsável pela sua segurança.

3. Conteúdo e componentes da embalagem

Before assembly, ensure all components listed below are present and undamaged. Refer to Figure 2 for visual identification.

  • Charles CVC370 Main Unit
  • Mangueira de sucção flexível
  • Stainless Steel Extension Tubes (Wand)
  • Combination Floor Tool (for carpets and hard floors)
  • Wet Pick-up Nozzle
  • Ferramenta para fendas
  • Escova para tirar pó
  • Bocal para estofamento
  • Dry Filter (for dry use)
  • Disposable Dust Bags (for dry use)
Various cleaning tools and attachments for Charles vacuum

Figure 2: A selection of the included cleaning tools and attachments.

4. Configuração e montagem

4.1 Montagem Inicial

  1. Retire todos os componentes da embalagem.
  2. Coloque a unidade principal sobre uma superfície estável e plana.
  3. Insert the flexible suction hose into the inlet port on the front of the main unit until it clicks securely into place.
  4. Connect the stainless steel extension tubes (wand) to the end of the flexible hose.
  5. Attach the desired floor tool or accessory to the end of the extension tubes.

4.2 Preparação para a aspiração a seco

For dry vacuuming, the dry filter and a disposable dust bag must be installed.

  1. Remove the top head of the vacuum by unlatching the clips on either side.
  2. Ensure the dry filter is securely seated over the motor housing inside the drum.
  3. Open a new disposable dust bag and fit its cardboard collar over the inlet spigot inside the drum. Ensure the bag is fully unfolded inside the drum.
  4. Replace the top head, ensuring the clips are securely latched.

4.3 Preparing for Wet Vacuuming

For wet vacuuming, the dry filter and dust bag must be removed. The float valve must be clear.

  1. Remove the top head of the vacuum.
  2. Carefully remove the dry filter and any installed dust bag. Store them in a clean, dry place.
  3. Ensure the float valve (a cage-like structure with a ball inside, located under the motor housing) is clean and free from debris. This valve prevents overfilling during wet pick-up.
  4. Replace the top head, ensuring the clips are securely latched.
  5. Attach the wet pick-up nozzle to the extension tubes.
Charles vacuum in a room setting

Figure 3: The Charles vacuum ready for operation in a typical room environment.

5. Instruções de operação

5.1 Aspiração a Seco

Ensure the vacuum is set up for dry use as described in Section 4.2.

  1. Ligue o cabo de alimentação a uma tomada elétrica de 240V adequada.
  2. Press the power switch located on the top of the unit to turn the vacuum on.
  3. Guide the floor tool or accessory over the surface to be cleaned. For carpets, use the brush down setting on the combination floor tool. For hard floors, use the brush up setting.
  4. When finished, press the power switch to turn the vacuum off and unplug it from the outlet.
Close-up of Charles vacuum floor tool on a hard floor

Figure 4: Using the Charles vacuum on a hard floor surface.

Person vacuuming a carpet with Charles

Figure 5: The Charles vacuum effectively cleaning a carpeted area.

5.2 Aspiração úmida

Ensure the vacuum is set up for wet use as described in Section 4.3.

  1. Ligue o cabo de alimentação a uma tomada elétrica de 240V adequada.
  2. Press the power switch to turn the vacuum on.
  3. Guide the wet pick-up nozzle over the liquid spill. The vacuum will automatically stop suction if the drum becomes full, indicated by a change in motor sound and loss of suction. This is the float valve activating.
  4. When finished or when the float valve activates, press the power switch to turn the vacuum off and unplug it from the outlet.
  5. Empty the collected liquid as described in Section 6.2.
Person using Charles to vacuum a liquid spill on a kitchen floor

Figure 6: Charles vacuum effectively cleaning a liquid spill in a kitchen.

5.3 Portabilidade

The Charles vacuum is designed with a convenient handle on top for easy transport between cleaning areas.

Person carrying Charles vacuum by its handle

Figure 7: Charles vacuum being carried, demonstrating its portability.

6. Manutenção

Regular maintenance ensures optimal performance and extends the life of your Charles vacuum cleaner. Always unplug the vacuum before performing any maintenance.

6.1 Emptying Dry Debris and Replacing Dust Bag

  1. Desconecte o aspirador.
  2. Unlatch the clips and remove the top head.
  3. Carefully remove the full dust bag by pulling the cardboard collar away from the inlet spigot. The self-seal tab will close the opening, preventing dust escape.
  4. Descarte o saco cheio de forma responsável.
  5. Install a new disposable dust bag as described in Section 4.2.
  6. Replace the top head and secure the clips.

6.2 Emptying Collected Liquids

  1. Desconecte o aspirador.
  2. Unlatch the clips and remove the top head.
  3. Carefully lift the drum and pour the collected liquid into a suitable drain.
  4. Rinse the inside of the drum with clean water and wipe dry.
  5. Ensure the float valve is clean and free of debris.
  6. Replace the top head and secure the clips.

6.3 Limpeza e Substituição do Filtro

The Charles CVC370 uses a HEPA filter and a washable filter.

  • Filtro seco: Periodically check the dry filter for dust build-up. Tap it gently to dislodge dust or brush it with a soft brush. If heavily soiled or damaged, replace it.
  • Filtro Lavável: Some components may be washable. Refer to the specific instructions provided with your filter type for washing and drying guidelines. Ensure all washable parts are completely dry before re-installing.

6.4 Limpeza da mangueira e dos acessórios

Inspect the hose and accessories regularly for blockages or damage. Clear any obstructions. Wipe down accessories with a damp pano conforme necessário.

7. Solução De Problemas

If you encounter issues with your Charles vacuum, refer to the table below for common problems and solutions.

ProblemaPossível causaSolução
O aspirador não liga.Sem fonte de alimentação.Verifique se o cabo de alimentação está firmemente conectado a uma tomada em funcionamento. Verifique o disjuntor.
Loss of suction (dry).Full dust bag, blocked hose/tool, dirty filter.Replace dust bag. Check hose and tools for blockages. Clean or replace dry filter.
Loss of suction (wet).Drum is full (float valve activated), blocked hose/tool.Empty the drum. Check hose and tools for blockages. Ensure float valve is clean.
Ruído incomum ou superaquecimento do motor.Blocked airflow, motor strain.Check for blockages in hose, tools, and filters. Ensure correct filter setup for wet/dry use. Allow motor to cool down.
Water leaking from unit (wet use).Drum overfilled, float valve obstructed, seals not properly seated.Empty the drum. Clean float valve. Ensure top head and seals are correctly seated.

8. Especificações

Technical specifications for the NUMATIC Charles CVC370 240V Vacuum Cleaner:

RecursoDetalhe
MarcaHenrique
Nome do modeloCarlos
Número do modelo do itemCVC370-2
Recurso especialWet, Bag, Dry (Dual Action)
Tipo de filtroHEPA Filter, Washable Filter
Capacidade15 litros
O quetage1200 watts
Sucção Máxima7.87 Feet H2O
Comprimento do cabo10 metros
Usos recomendadosCarpet, Hard Floor, Wet Applications
Fator de formaVasilha
Dimensões do produto13.98" de largura
Nível de ruído70 dB
Peso do item19.8 libras
FabricanteAvern Cleaning Supplies
UPC790914217846

9. Informações de garantia

For detailed warranty information regarding your NUMATIC Charles CVC370 vacuum cleaner, please refer to the warranty card included with your purchase or visit the official Henry/Numatic International webOs termos e condições da garantia podem variar conforme a região e o revendedor.

10. Suporte ao cliente

Should you require further assistance, have questions not covered in this manual, or need to order replacement parts, please contact your retailer or the manufacturer's customer support. Contact details can typically be found on the manufacturer's official website ou na embalagem do produto.

Documentos relacionados - CVC370-2

Préview Manual do Proprietário das Banheiras de Hidromassagem Autolimpantes Hydropool Signature
Manual do proprietário completo para banheiras de hidromassagem autolimpantes Hydropool Signature, abrangendo instalação, operação, segurança, manutenção e solução de problemas para diversos modelos.
Préview Numatic Henry Wash HVW370: Guia de operação, manutenção e limpeza
Um manual do usuário detalhado para o Numatic Henry Wash HVW370, abrangendo o conjunto para limpeza de carpetes, pisos duros e estofados, instruções de uso, segurança química (NuChem 4), procedimentos de manutenção, localização de falhas e especificações técnicas.
Préview Manual de instruções do proprietário do Numatic HVR 200-11 e HET 200-11
Instruções abrangentes para o proprietário dos aspiradores de pó Numatic HVR 200-11 e HET 200-11, abrangendo montagem, operação, limpeza, manutenção, segurança e especificações técnicas.
Préview Manual do proprietário e instruções do aspirador de pó Numatic Henry & Hetty
Manual do proprietário completo para aspiradores de pó Numatic Henry e Hetty (HVR 160-11, HET 160-11). Inclui informações sobre montagem, operação, manutenção, segurança, especificações e garantia.
Préview Manual do usuário e instruções da torradeira de pão PowerPac PPT03 para 2 fatias
Manual do usuário completo para a torradeira de pão PowerPac PPT03 de 2 fatias, abrangendo peças, avisos de segurança, instruções de operação, limpeza e informações de garantia.
Préview Manual do usuário, especificações e garantia do aspirador de pó Numatic HENRY/HETTY 160-11 (XTEND)
Comprehensive user manual, assembly instructions, maintenance guide, safety information, technical specifications, and warranty details for the Numatic HENRY/HETTY 160-11 (XTEND) commercial dry vacuum cleaner. Includes product data, replacement parts, and contact information.