1. Introdução
The Phoenix DEI 508D Proximity Radar Motion Sensor is designed to enhance the security of your vehicle by detecting motion both inside and outside the vehicle. This dual-zone sensor provides an early warning system, triggering your car alarm upon detecting unauthorized proximity or intrusion. This manual provides detailed instructions for installation, operation, and maintenance to ensure optimal performance and longevity of your sensor.
2. Informações de segurança
- Always disconnect the vehicle's battery before beginning any electrical installation to prevent short circuits or electrical shock.
- Ensure all wiring connections are secure and properly insulated to prevent fire hazards or system malfunctions.
- Do not attempt to modify the sensor's internal components. Unauthorized modifications can void the warranty and pose safety risks.
- Consulte um técnico automotivo profissional se tiver dúvidas sobre qualquer etapa da instalação.
- Keep the sensor away from excessive moisture, heat, and direct sunlight to prevent damage.
3. Conteúdo da embalagem
Ao abrir a embalagem, verifique se todos os componentes estão presentes e sem danos:
- DEI 508D Proximity Radar Motion Sensor Unit
- Chicote de Fiação
- Guia de instalação (este manual)

Figure 3.1: The Phoenix DEI 508D Proximity Radar Motion Sensor shown in its clear retail packaging, displaying the main sensor unit with its green circuit board visible, and a bundled wiring harness with multiple colored wires (red, black, blue, green, purple) connected to a white connector. The packaging also features the 'Directed INSTALL essentials' logo and text indicating 'Dual Zone Motion Sensor' and 'Motion detector for the interior and exterior of your vehicle.'
4. Configuração e instalação
4.1 Lista de verificação de pré-instalação
- Certifique-se de que a bateria do veículo esteja desconectada.
- Gather necessary tools: wire strippers, crimpers, electrical tape, zip ties, multimeter.
- Identify a suitable mounting location for the sensor.
4.2 Diagrama de fiação e conexões
The DEI 508D sensor typically connects to your existing car alarm system. Refer to your car alarm's manual for specific input requirements. Common connections are:
- Fio vermelho: +12V Constant Power. Connect to a fused constant 12V source.
- Fio preto: Ground. Connect to a solid chassis ground point.
- Fio Azul: Zone 1 Output (Warn-Away). Connect to the alarm's warn-away or pre-warn input. This output is typically a negative pulse.
- Fio Verde: Zone 2 Output (Full Trigger). Connect to the alarm's full trigger input. This output is typically a negative pulse.
- Purple Wire: Ignition Input. Connect to a switched 12V source that is active when the ignition is ON. This wire is used to disable the sensor when the vehicle is running.
4.3 Montagem do Sensor
Choose a central location within the vehicle's cabin, such as under the dashboard, center console, or behind the glove compartment. The sensor should be mounted securely and away from direct metal obstructions that could interfere with its radar field. Ensure the sensor is level and not obstructed by large metal objects or wiring harnesses.
- Use zip ties or double-sided automotive tape to secure the sensor firmly.
- Avoid mounting near large speakers or other devices that emit strong electromagnetic fields.
- Test the sensor's coverage after mounting to ensure optimal detection zones.
5. Instruções de operação
The DEI 508D sensor operates automatically once properly installed and connected to your car alarm system. It creates two distinct detection zones: an outer
Documentos relacionados - DEI-508D
![]() |
Instruções de operação da fechadura eletrônica da série Phoenix DS2500E Manual de instruções completo para a fechadura eletrônica Phoenix DS2500E Series, abrangendo configuração, gerenciamento de código, controle duplo, recursos de alarme e substituição da bateria. |
![]() |
Desempenho LGR da Phoenix Solution AmpManual do Proprietário e Guia de Instalação do lifier Manual do proprietário, instruções de instalação, operação e serviço para o Therma-Stor Phoenix Solution LGR Performance Amplifier (PN 4026600). Saiba mais sobre suas especificações, configuração, manutenção e garantia. |
![]() |
Manual do proprietário e instruções de serviço do desumidificador Phoenix 250 MAX LGR Manual do proprietário completo para o desumidificador Phoenix 250 MAX LGR da Therma-Stor. Abrange instalação, operação, manutenção, solução de problemas, especificações e garantia para este equipamento de restauração de alta capacidade. |
![]() |
Desempenho LGR da Phoenix Solution AmpManual do Proprietário do lifier Manual do proprietário do Therma-Stor Phoenix Solution LGR Performance Amplifier, abrangendo instalação, operação, serviço, especificações, solução de problemas e informações de garantia. |
![]() |
Manual do Proprietário do Desumidificador Phoenix 200 MAX LGR: Instruções de Instalação, Operação e Manutenção Manual do proprietário completo para o desumidificador de alta capacidade Phoenix 200 MAX LGR, abrangendo informações sobre instalação, operação, manutenção, solução de problemas e garantia da Therma-Stor. |
![]() |
Manual do Proprietário do Desumidificador Phoenix 200 HT LGR | Instalação, Operação, Manutenção Manual do proprietário completo do desumidificador Phoenix 200 HT LGR da Therma-Stor. Abrange especificações, operação, manutenção, solução de problemas, serviços, peças e garantia para este equipamento de restauração de alto desempenho. |