1. Produto acabadoview
The Taco Flo-Check valve, Model T-220, is designed for use in forced hot water heating systems. Its primary function is to prevent unwanted "gravity" circulation of hot water during periods when the boiler is hot but the space heating zone does not require heat. This mechanism allows for efficient operation, enabling the heating boiler to maintain domestic hot water year-round without inadvertently heating other zones.
In systems with multiple circulator zones, Flo-Cheks ensure that heat is directed only to the zones that are actively calling for it, optimizing energy use. The valve also features a thumb screw that can be manually opened, providing a gravity feed option if the main circulator ceases operation.
2. Recursos do Produto
- Tamanho da conexão: 1-Inch Cast Iron NPT (National Pipe Taper)
- Instalação: Universal design for versatile application
- Pressão máxima de operação: 125 PSI (libras por polegada quadrada)
- Temperatura operacional máxima: 277 degrees Fahrenheit (136 degrees Celsius)
- Material: Durable Cast Iron construction
3. Configuração e instalação
Installation of the Taco T-220 Flo-Check valve should be performed by a qualified heating technician in accordance with local plumbing and heating codes. Ensure the system is depressurized and cooled before beginning installation.

This image displays the Taco T-220 Universal Flo-Check valve. It features a robust green cast iron body with threaded connections on both sides for inline installation. A knurled adjustment knob is visible on the top, used for manual override.
- Preparação do sistema: Drain the heating system to a safe level, ensuring no hot water or pressure remains.
- Colocação: Install the Flo-Check valve in the appropriate location within the forced hot water heating system, typically on the supply side of the heating zone it controls. Refer to your system's design for optimal placement.
- Conexão: Utilize the 1-inch NPT threaded connections to integrate the valve into the piping. Apply appropriate thread sealant to ensure leak-free connections.
- Orientação: Ensure the valve is installed with the correct flow direction as indicated by any markings on the valve body.
- Recarga do sistema: After installation, slowly refill the heating system, bleeding air as necessary. Inspect all connections for leaks.
4. Instruções de operação
The Taco T-220 Flo-Check valve operates automatically to prevent gravity circulation. When a heating zone calls for heat, the circulator pump activates, creating sufficient flow to open the valve and allow hot water to enter the zone. When the circulator is off, the valve closes, preventing unwanted thermal siphoning.
Manual Override (Thumb Screw): The valve is equipped with a thumb screw on top. This screw can be manually opened to allow for gravity feed applications. This feature is useful in situations where the main circulator pump is not operating, allowing for some heat transfer via natural convection. To engage gravity feed, turn the thumb screw counter-clockwise until it is fully open. To return to automatic operation, turn the thumb screw clockwise until it is fully closed.
5. Manutenção
The Taco T-220 Flo-Check valve is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection is recommended to ensure optimal performance:
- Inspeção de vazamento: Annually inspect the valve and its connections for any signs of leaks. Address any leaks promptly.
- Thumb Screw Operation: Periodically check that the manual override thumb screw can be easily turned and fully opened and closed. This ensures the manual gravity feed function remains available if needed.
- Qualidade da água do sistema: Maintaining proper water quality in your heating system can extend the life of all components, including the Flo-Check valve.
6. Solução De Problemas
If your heating system is not performing as expected, consider the following:
- Unwanted Heat Transfer (Gravity Circulation): If heat is entering a zone when its circulator is off, the Flo-Check valve may be stuck open or improperly installed. Ensure the thumb screw is fully closed.
- No Heat to Zone: If a zone's circulator is running but no heat is reaching the zone, the Flo-Check valve might be stuck closed. Check if the thumb screw is fully open (for manual override testing) or if there's an obstruction.
- Vazamentos: Any visible leaks should be addressed immediately by tightening connections or replacing seals/components as necessary.
For persistent issues or complex problems, it is recommended to contact a qualified HVAC technician.
7. Especificações
| Número do modelo | T-220 |
| Material | Ferro fundido |
| Tamanho da conexão | 1-Inch NPT |
| Diâmetro externo | 40 milímetros |
| Espessura do Item | 2 polegadas |
| Dimensões do produto (C x L x A) | 2 x 3 x 5 polegadas |
| Peso do item | 2.45 libras |
| Operating Pressure (Max) | 125 PSI |
| Faixa de temperatura operacional | 45-277 graus Fahrenheit |
| Cor | Verde |
8. Garantia e Suporte
The Taco T-220 Universal Flo-Check Valve comes with a Garantia limitada de 1 ano a partir da data da compra. Esta garantia cobre defeitos de materiais e de fabricação sob uso e serviço normais.
For warranty claims, technical assistance, or further information regarding your Taco product, please contact Taco customer support. Keep your proof of purchase for warranty validation.
Informações de contato: Please refer to the official Taco webPara obter os dados de contato mais recentes do suporte ao cliente, consulte o site ou a embalagem do produto.





