Introdução
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wayne SWS75 0.75 HP Shallow Well Jet Pump. Please read these instructions thoroughly before use to ensure proper function and longevity of the pump.

Image: Wayne Shallow Well Jet Pump branding banner.
Informações de segurança
Always observe safety precautions to reduce the risk of injury, electric shock, or property damage. This pump operates with electricity and water, which can be hazardous if not handled correctly.
- Segurança elétrica: Ensure all electrical connections comply with local codes. The motor is thermally protected to prevent overheating; however, proper wiring is crucial.
- Segurança da Água: Do not operate the pump dry. Ensure the pump is properly primed before starting.
- Instalação: Follow all installation instructions carefully. Improper installation can lead to pump failure or safety hazards.
- Manutenção: Desligue a energia antes de realizar qualquer manutenção ou serviço.
Produto acimaview
The Wayne SWS75 is a 0.75 horsepower shallow well jet pump designed for wells up to 25 feet deep. It features a durable cast iron volute and an efficient square flange motor that is thermally protected to prevent overheating.

Imagem: Frente view of the Wayne SWS75 0.75 HP Shallow Well Jet Pump.
Principais características:
- Potência: 0.75 HP
- Taxa Máxima de Fluxo: 510 gallons per hour (GPH) at 50 PSI
- Well Depth: Suitable for wells 0 ft. to 25 ft. in depth
- Descarga: 3/4 polegada NPT
- Sucção: NPT de 1-1/4 polegada
- Interruptor de pressão: Pre-set at 30-50 PSI for automatic operation
- Construção: Durable cast iron volute with a dedicated priming port
- Motor: Efficient square flange motor, thermally protected
- Conjunto: Assembled in the USA with foreign and domestic parts.

Image: Diagram highlighting key features of the Wayne SWS75 pump, including USA assembly, self-priming, dual voltage, and intake/discharge sizes.
Configuração e instalação
Proper installation is critical for the performance and safety of your pump. Consult a qualified professional if you are unsure about any steps.
1. Location and Mounting:
- Install the pump on a solid, level surface to minimize vibration.
- Ensure the pump is protected from freezing temperatures and direct weather exposure.
- The pump is designed for shallow wells up to 25 feet deep.
2. Conexões de Encanamento:
- Connect the suction line to the 1-1/4 inch NPT intake port.
- Connect the discharge line to the 3/4 inch NPT discharge port.
- Use appropriate pipe sealant on all threaded connections to prevent leaks.
- Ensure all piping is adequately supported to avoid strain on the pump.
3. Preparando a bomba:
Before initial operation, the pump must be properly primed.
- Remove the priming plug located on the pump volute.
- Fill the pump volute completely with water through the dedicated priming port until water overflows.
- Recoloque o bujão de escorva firmemente.
- Ensure the suction line is also filled with water to the well.
4. Conexão elétrica:
- The pump operates on 120 Volts and is dual voltage 120V/240V capable. Ensure your power supply matches the pump's configuration.
- Connect the pump to a dedicated, properly grounded electrical circuit.
- Consult a licensed electrician for wiring if you are not familiar with electrical installations.
Instruções de operação
Após a instalação e o escorva, a bomba está pronta para funcionar.
- Inicialização inicial: Turn on the power supply to the pump. The pump should start and begin to build pressure.
- Operação automática: The integrated pressure switch is pre-set to turn the pump on at 30 PSI and off at 50 PSI, maintaining consistent water pressure.
- Monitoramento: Observe the pressure gauge (if installed) to ensure the pump is operating within the expected pressure range.
- Operação contínua: The pump is designed for intermittent use as demand requires. Avoid prolonged dry running.
Manutenção
A manutenção regular garante o desempenho ideal e prolonga a vida útil da sua bomba.
- Desconecte a energia: Desligue sempre a fonte de alimentação antes de realizar qualquer manutenção.
- Inspecionar conexões: Verifique periodicamente todas as conexões hidráulicas e elétricas quanto a vazamentos ou corrosão. Aperte-as conforme necessário.
- Ventilação limpa: Ensure motor cooling vents are clear of debris to prevent overheating.
- Winterização: In areas subject to freezing temperatures, drain the pump and piping completely to prevent damage.
Solução de problemas
Esta seção aborda problemas comuns que você pode encontrar com sua bomba.
| Problema | Possível causa | Solução |
|---|---|---|
| A bomba funciona, mas não há água ou a pressão está baixa. |
|
|
| A bomba funciona com muita frequência |
|
|
| A bomba não inicia |
|
|
Especificações
Detailed technical specifications for the Wayne SWS75 0.75 HP Shallow Well Jet Pump.
| Modelo | SWS75 |
| Potência | 0.75 HP |
| Taxa de fluxo máxima | 510 GPH (at 50 PSI) |
| Altura máxima de elevação | 25 pés |
| Volumetage | 120 Volts (Dual voltage 120V/240V capable) |
| Tamanho de Descarga | 3/4 polegada NPT |
| Tamanho de sucção | NPT de 1-1/4 polegada |
| Configuração do interruptor de pressão | 30-50 PSI (Pre-set) |
| Material | Ferro fundido |
| Peso do item | 38.6 libras |
| Dimensões do produto (C x L x A) | 22.3" x 11.5" x 10.3" |
Performance Data (Gallons Per Hour - GPH):

Image: Performance table showing GPH at various depths (0', 5', 10', 15', 20', 25') for 30, 40, and 50 PSI.
| PSI | 0' Depth (GPH) | 5' Depth (GPH) | 10' Depth (GPH) | 15' Depth (GPH) | 20' Depth (GPH) | 25' Depth (GPH) |
|---|---|---|---|---|---|---|
| 30 | 779 | 750 | 721 | 691 | 662 | 633 |
| 40 | 644 | 615 | 586 | 557 | 528 | 499 |
| 50 | 510 | 481 | 451 | 422 | 393 | 364 |
Informações de garantia
The Wayne SWS75 Well Jet Pump comes with a Garantia limitada de 3 anos covering parts only. Please retain your proof of purchase for warranty claims. For full warranty terms and conditions, refer to the documentation included with your product or visit the manufacturer's website.
Suporte ao cliente
For technical assistance, replacement parts, or further inquiries, please contact Wayne customer support. Contact details can typically be found on the manufacturer's official weblocal ou nos materiais de embalagem.
Note: Always provide your pump's model number (SWS75) and serial number when contacting support.