The Bogen Multi-Zone Page Controller BG-UTI312 is engineered for multi-zone paging in one-way audio applications, specifically designed for self-amplified speaker systems. Each output is capable of providing audio for up to 150 self-amplified speakers. This unit is compatible with all standard analog port types and offers extensive configuration options for various paging needs. This manual provides essential information for the proper installation, operation, and maintenance of your BG-UTI312 unit.

Configuração e instalação

The BG-UTI312 comes with a pre-installed ZX3 module, providing three zones of paging capability. The system is expandable up to 12 zones by adding additional modules. Installation involves connecting the unit to your existing telephone system and self-ampalto-falantes lificados.

  • Expansão da Zona: The unit is expandable up to 12 zones.
  • Interfaces telefônicas: Supports loop start trunk, ground start trunk, station access (analog ring-up), page port contact closure activation, and page port voice activation.
  • Configuração: Features a simple 2-switch interface setup for initial configuration.
  • Contatos Auxiliares: Programmable activation of AUX contacts is available.
  • Zone Contacts: Includes a C-form contact per zone for flexible integration.
  • Fonte de energia: Utilizes a 24V DC, 1A internal power supply.
  • Speaker Capacity: Provides audio drive for up to 150 one-way self-amplified speakers per zone.
  • Terminal Strips: Pluggable terminal strips facilitate easy wiring and maintenance.
Front panel of the Bogen BG-UTI312 Multi-Zone Page Controller showing various inputs, outputs, and controls.

Imagem 1: This image displays the front panel of the Bogen BG-UTI312, highlighting the music inputs, limiter/threshold controls, interface type selectors, power indicators, and zone connections (1-3, 4-6, 7-9, 10-12).

Instruções de operação

The BG-UTI312 offers a range of operational features for comprehensive paging and background music management.

  • Output Limiter: An adjustable output limiter with threshold control and an active indicator helps prevent audio distortion.
  • Música de fundo: Two background music busses are available, selectable per zone. The unit features two high-impedance transformer-isolated background music inputs with stereo combining inputs for these busses.
  • Paging Zone Groups: Up to 24 programmable paging zone groups can be configured, including:
    • All-Call paging zone group.
    • Auto Select paging zone group.
    • Override paging (activated via loop start trunk or page port contact closure).
    • Night Ringer (90V and contact closure activation) with a dedicated zone group.
    • Two Tone Triggers (tone and duration selectable, closure activated) with individual zone groups. Tone options include tone burst, chime, double chime, or slow whoop.
    • Code Calling with a dedicated zone group.
  • Discagem: Supports 2 to 5 digit dialing with a flexible dialing plan for zone and zone group numbers.
  • Tons: Includes Pre-Announce Tone, Confirmation Tone, and a Setup Tone to assist in volume setting.
  • Programação: DTMF programming is used for configuration. DTMF Block helps suppress DTMF tones over the paging system.

Manutenção

The Bogen BG-UTI312 is designed for reliable operation with minimal maintenance.

  • Memória: Setup data is stored in non-volatile memory, eliminating the need for a backup battery.
  • Limpeza: Mantenha o aparelho limpo e livre de poeira. Use um pano macio e seco para a limpeza. Evite produtos de limpeza líquidos.
  • Ventilação: Assegure-se de que haja ventilação adequada ao redor do aparelho para evitar superaquecimento. Não obstrua as aberturas de ventilação.
  • Conexões: Periodically check all connections to ensure they are secure. The pluggable terminal strips allow for easy inspection and re-connection.

Solução de problemas

If you encounter issues with your Bogen BG-UTI312, consider the following general troubleshooting steps. The microcontroller-based operation provides stable performance, but basic checks can resolve common problems.

  • Sem energia: Verify the power connection and check the fuse rating (1A/125V). Ensure the 24V DC power supply is functioning correctly.
  • No Paging Audio: Check all audio input and output connections. Confirm that the correct zone is selected and that the output limiter is not set too low. Verify telephone interface connections.
  • Áudio distorcido: Adjust the output limiter threshold. Ensure input levels are not overdriving the system.
  • Incorrect Zone Paging: Review your dialing plan and zone group configurations. Ensure the correct digits are being dialed for the desired zone or group.
  • Background Music Issues: Check background music input connections and ensure the correct bus is selected for the zone. Verify input levels.

For persistent issues, consult a qualified technician or contact Bogen technical support.

Especificações

Dimensões do produto19 x 7 x 6.5 polegadas
Peso do item0.01 onças
FabricanteArco
Número do modeloBG-UTI312
Fonte de energia24V DC, 1A (internal)
Capacidade da Zona3 to 12 zones (expandable with modules)
Speaker CapacityUp to 150 one-way self-amplified speakers per zone
Paging Zone GroupsAté 24 programáveis
MemóriaNon-volatile for setup data
Alternativa view of the Bogen BG-UTI312 Multi-Zone Page Controller.

Imagem 2: This image provides another perspective of the Bogen BG-UTI312, showing the overall chassis and the arrangement of its various connection points and controls.

Informações de garantia

The Bogen Multi-Zone Page Controller BG-UTI312 comes with a Garantia de 2 ano. Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the official warranty documentation provided with your product or visit the Bogen website.

Apoiar

For technical assistance, product inquiries, or service requests, please contact Bogen customer support. Refer to the contact information provided on the Bogen official website or in the packaging materials for the most current support channels.

Documentos relacionados - BG-UTI312

Préview Manual de instalação e uso do controlador de zona e interface telefônica universal Bogen UTI312
Manual de instalação e uso do controlador de zona Bogen UTI312 com interface telefônica universal, detalhando seus recursos, configuração e diretrizes operacionais para sistemas de sinalização e paginação multizona.
Préview Bogen TPU Series Telephone Paging Amplifiers: Installation and Use Manual
Comprehensive installation and use manual for Bogen TPU35B, TPU60B, TPU100B, and TPU250 telephone paging amplifiers, covering setup, wiring, operation, and specifications.
Préview Painel de controle mestre Bogen MCP35A: Manual de instalação e uso
Este manual fornece instalação detalhada, operação e especificações técnicas para o Painel de Controle Mestre Bogen MCP35A, um sistema versátil para comunicação bidirecional e distribuição de programas em vários ambientes.
Préview Alto-falante de corneta reentrante Bogen IH8A - Especificações do produto e instalação
Informações completas sobre a caixa acústica Bogen IH8A Reentrant Horn, incluindo suas características, especificações técnicas, guia de montagem e instalação e informações sobre a garantia limitada.
Préview Guia de Configuração do Módulo de Intercomunicação VoIP Bogen Nyquist (NQ-GA10P, NQ-GA10PV)
Guia de configuração detalhado para os módulos de intercomunicação VoIP Nyquist NQ-GA10P e NQ-GA10PV da Bogen. Abrange a configuração inicial, as definições de rede, as atualizações de firmware e o funcionamento autónomo de sistemas de paginação IP e distribuição de áudio.
Préview Bogen VAR1 Voice-Activated Relay: Technical Specifications and Operation
Detailed specifications, installation, operation, and warranty information for the Bogen VAR1 Voice-Activated Relay, a DPDT relay device for audio signal activation and muting.