1. Introdução
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TCS NGV1011-0400 Intercom Accessory Control Unit. Please read this manual thoroughly before attempting to install or operate the device. Retain this document for future reference.
2. Informações de segurança
AVISO: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect power before installation or maintenance.
- Assegure-se de que todos os códigos elétricos locais e nacionais sejam seguidos durante a instalação.
- Não exponha o aparelho à umidade ou a temperaturas extremas.
- Verifique o vol corretotagVerifique as classificações de tensão e corrente antes de conectar a energia.
- Always use appropriate tools and personal protective equipment.
3. Produto acabadoview
The TCS NGV1011-0400 is an accessory control unit designed for intercom systems, typically used with door stations. It functions as a power supply and control interface, converting AC input to DC output for system components.

Figure 1: TCS NGV1011-0400 Intercom Accessory Control Unit. This image displays the TCS NGV1011-0400 intercom accessory control unit. The front panel features the TCS logo, model number NGV1011-0400, and CE marking. Terminal blocks are visible at the top and bottom for electrical connections. The label indicates an output voltage of 26 V DC / 2.5 A and AC input terminals L, N, PE.
Principais características:
- Designed for door station applications.
- Vol de entradatage: 230 V CA.
- Volume de saídatage: 26 V DC at 2.5 A.
- Integrated terminal blocks for secure wiring.
4. Configuração e instalação
Before beginning installation, ensure the main power supply is disconnected. The unit is designed for DIN rail mounting within an electrical enclosure.
4.1 Conexões de Fiação:
Refer to the product label and Figure 1 for terminal identification.
- AC Input (Terminals L, N, PE): Connect the 230 V AC mains power supply to these terminals.
- L (Linha): Conecte-se ao fio energizado.
- N (Neutro): Conecte ao fio neutro.
- PE (Protective Earth): Connect to the protective earth ground.
- DC Output (Terminals 29, 31): These terminals provide the 26 V DC / 2.5 A output for the intercom system components.
- Terminal 29: Connect to the negative (-) DC input of the intercom component.
- Terminal 31: Connect to the positive (+) DC input of the intercom component.
- Control Output (Terminal 36): This terminal is typically used for control signals, such as activating a door opener or a light. Consult your intercom system's specific wiring diagram for its function.
After all connections are made, double-check wiring for correctness and secureness before restoring power.
5. Instruções de operação
The TCS NGV1011-0400 operates automatically once correctly installed and powered. It provides the necessary power and control signals to the connected intercom system. There are no user-adjustable controls on the unit itself.
- Ligar: Once AC power is supplied to the L, N, PE terminals, the unit will power on and provide 26 V DC output.
- Integração do sistema: The functionality of the NGV1011-0400 is integrated with the overall intercom system. Refer to the manual of your specific intercom system for operational details.
6. Manutenção
The TCS NGV1011-0400 is designed for minimal maintenance. Regular inspections are recommended to ensure optimal performance.
- Limpeza: Desligue a alimentação antes de limpar. Use um pano macio e seco para limpar a parte externa do aparelho. Não use produtos de limpeza líquidos ou solventes.
- Inspeção: Periodically check all wiring connections for tightness and signs of wear or damage. Ensure the unit is free from dust accumulation, which can impede cooling.
- Condições ambientais: Assegurar que o ambiente operacional permaneça dentro das faixas de temperatura e umidade especificadas.
7. Solução De Problemas
If the intercom system is not functioning correctly, consider the following troubleshooting steps related to the NGV1011-0400 unit:
- Sem saída de energia:
- Verify that the 230 V AC mains power supply is active and correctly connected to terminals L, N, and PE.
- Check for tripped circuit breakers or blown fuses in the main electrical panel.
- Ensure all DC output connections (Terminals 29, 31) are secure and correctly polarized.
- Operação intermitente:
- Inspect all wiring for loose connections or damaged insulation.
- Ensure the unit is not overheating due to inadequate ventilation or excessive load.
- If problems persist after performing these checks, contact qualified service personnel. Do not attempt to repair the unit yourself.
8. Especificações
| Parâmetro | Valor |
|---|---|
| Marca | TCS |
| Número do modelo | NGV1011-0400 |
| Aplicativo | Door Station Accessory / Intercom Control Unit |
| Vol de entrada ACtage | 230 V |
| Freqüência | 50 Hz |
| Volume de saída CCtage / atual | 26 V DC / 2.5 A |
| Peso do item | 200 gramas |