1. Produto acabadoview
The Fluke 179/EDA2 Industrial Electronics Multimeter Combo Kit is a full-featured digital multimeter (DMM) designed for advanced electronic troubleshooting. This kit includes the Fluke 179 True RMS Digital Multimeter with backlight, along with a comprehensive set of probes and accessories, all housed in a durable carrying case.
The Fluke 179 multimeter offers a wide range of measurement functions, adheres to the latest safety standards, and features a large, easy-to-view mostrar.
Conteúdo do kit:
- Fluke 179 True RMS Digital Multimeter with backlight
- Fluke TL224 Silicone Test Leads
- Fluke TL910 Electronic Test Probes with replacement tips
- Fluke AC280 Heavy Duty Hook Clips
- Fluke 80BK-A Integrated Temperature Probe
- Fluke C35 Durable Carrying Case
- TPAK Magnetic Meter Hanger

2. Configuração
2.1. Instalação da bateria
The Fluke 179 Multimeter requires 4 AA alkaline batteries for operation. These are typically included with the kit. To install or replace batteries, refer to the instructions provided in the quick start guide or the full user manual for your specific model. Generally, this involves opening the battery compartment on the rear of the device, inserting the batteries with correct polarity, and securing the cover.
2.2. Conectando cabos de teste
Ensure the multimeter is turned off before connecting or disconnecting test leads. Insert the black test lead into the COM (common) input jack and the red test lead into the appropriate input jack for your desired measurement (e.g., VΩmA for voltage, resistance, or current measurements).

For specialized measurements, use the included accessories:
- Fluke TL224 Silicone Test Leads: Standard leads for general measurements.
- Fluke TL910 Electronic Test Probes with replacement tips: Ideal for precision work on small electronic components.
- Fluke AC280 Heavy Duty Hook Clips: For secure connections to larger terminals or wires.
- Fluke 80BK-A Integrated Temperature Probe: Connect to the appropriate input jacks for temperature measurements.



3. Instruções de operação
The Fluke 179 Multimeter offers a variety of measurement functions. Always select the correct function and range before making a measurement to ensure accuracy and safety.
3.1. Medidas básicas
- Volumetage (AC/DC): Turn the rotary switch to V~ (AC) or V- (DC). Connect the test leads in parallel with the circuit or component to be measured.
- Corrente (CA/CC): Turn the rotary switch to A~ (AC) or A- (DC) or mA/µA. Connect the test leads in series with the circuit. Ensure the correct input jack is used for the expected current level.
- Resistência (Ω): Turn the rotary switch to Ω. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance.
- Continuidade: Turn the rotary switch to the continuity symbol (speaker icon). The meter will beep if a continuous path is detected.
- Teste de Diodo: Turn the rotary switch to the diode symbol. Connect the test leads across the diode to check its forward voltage gota.
3.2. Recursos avançados
- Manual and Automatic Ranging: The multimeter can automatically select the appropriate measurement range. For specific applications, manual ranging can be selected.
- Retenção de exibição: Pressione o botão HOLD para congelar a leitura atual no visor.
- Retenção automática: Automatically holds stable readings on the display.
- Min/Max-Average Recording: Capture minimum, maximum, and average readings over a period, useful for monitoring fluctuating signals.
- Frequency (Hz) and Capacitance (F) Measurements: Select the appropriate function on the rotary switch to measure frequency or capacitance.
- Medição de temperatura: Connect the Fluke 80BK-A Integrated Temperature Probe to the multimeter and select the temperature function to measure temperature.


3.3. Demonstrações em vídeo
4. Manutenção
4.1. Cuidados Gerais
To ensure the longevity and accuracy of your Fluke 179 Multimeter, keep it clean and dry. Wipe the case with a damp cloth and mild detergent as needed. Do not use abrasives or solvents. Store the multimeter and its accessories in the provided Fluke C35 Durable Carrying Case when not in use to protect them from dust and physical damage.
4.2. Substituição da bateria
When the low battery indicator appears on the display, replace the 4 AA alkaline batteries promptly. Always use fresh batteries of the specified type. Refer to the user manual for detailed instructions on safely opening the battery compartment and replacing the batteries.
5. Solução De Problemas
If you encounter issues with your Fluke 179 Multimeter, consider the following basic troubleshooting steps:
- Sem problemas de exibição/energia: Check battery levels and ensure they are correctly installed. Replace batteries if necessary.
- Leituras imprecisas: Verify that the correct function and range are selected for the measurement. Ensure test leads are properly connected and not damaged. Clean the test lead tips if they appear corroded.
- "OL" (Overload) Indication: This indicates that the measured value exceeds the selected range. Switch to a higher range or a different measurement function if applicable.
- Teste de continuidade/diodo não funciona: Ensure the circuit is de-energized before performing these tests. Check for proper lead connection.
For more complex issues, consult the full Fluke 179 user manual or contact Fluke customer support.
6. Especificações
| Recurso | Detalhe |
|---|---|
| Número do modelo | FLUKE-179/EDA2 |
| Dimensões do produto | 11.54 x 16 x 3.35 polegadas |
| Peso do item | 1.95 libras |
| Fonte de energia | Pilhas Alcalinas |
| Pilhas necessárias | 4 pilhas AA (incluídas) |
| Fabricante | Corporação Fluke |
| Estilo | ELECTRONICS DMM AND DELUXE ACCESSORY COMBO KIT |
7. Garantia e Suporte
For warranty information and technical support, please refer to the documentation included with your Fluke 179/EDA2 kit or visit the official Fluke website. Fluke products are known for their reliability and often come with comprehensive support.
Você pode visitar o Loja Fluke na Amazon Para obter mais detalhes sobre o produto e recursos de suporte.