This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic T1906 SPDT 24-Hour Time Switch. Please read all instructions carefully before installation and use to ensure proper function and safety.

Informações importantes de segurança:

  • Always disconnect power at the circuit breaker before installing or servicing the time switch.
  • A instalação deve ser realizada por um eletricista qualificado, em conformidade com todos os códigos elétricos locais e nacionais.
  • This device is designed for indoor use within a 3R steel enclosure.

Produto acimaview

The Intermatic T1906 is a robust 24-hour time switch designed for automatic control of electrical loads. It features a single-pole, double-throw (SPDT) switch and operates on 208-277 Volts. Key features include:

  • Up to 96 operations (48 ON/48 OFF) every 24 hours.
  • 15-minute minimum ON/OFF intervals.
  • Captive trippers for easy setting.
  • Suitable for applications requiring daily repetitive scheduling.

Instalação

Precauções de segurança

  • Ensure power is OFF at the main service panel before beginning installation.
  • Verificar voltage supply matches the time switch rating (208-277V).
  • Ground the enclosure properly.

Montagem

  1. Select a suitable indoor location for the 3R steel enclosure, protected from direct weather and excessive moisture.
  2. Mount the enclosure securely using appropriate fasteners through the pre-drilled holes.

Fiação

Refer to the wiring diagram provided inside the enclosure cover. The T1906 is an SPDT switch, meaning it has one common terminal and two switched terminals (normally open and normally closed).

  1. Conecte a linha de entrada voltage to the designated line terminal.
  2. Connect the load(s) to the appropriate switched terminals (NO or NC) and the neutral/return line.
  3. Certifique-se de que todas as conexões estejam firmes e seguras.
  4. CUIDADO: Make sure non-operating trippers (if any) clear the switch lever.
  5. IMPORTANTE: The insulator must be replaced after wiring to prevent shock.
Intermatic T1906 Time Switch internal view showing the 24-hour dial with captive trippers and warning labels.

Figura 1: Interno view of the Intermatic T1906 Time Switch. This image displays the 24-hour clock dial with numerous small, gold-colored captive trippers around its circumference. A central silver hand indicates the current time. Below the dial, a translucent plastic insulator covers wiring terminals, with a warning label visible: "CAUTION: MAKE SURE NON-OPERATING TRIPPERS (IF ANY) CLEAR SWITCH LEVER" and "THIS INSULATOR MUST BE REPLACED AFTER WIRING TO PREVENT SHOCK."

Instruções de operação

Definir o tempo

  1. Gire o mostrador clockwise only until the current time aligns with the time indicator arrow. The dial is marked with AM and PM hours.

Setting ON/OFF Times

The T1906 uses captive trippers around the dial to set ON and OFF times. Each tripper represents a 15-minute interval.

  1. To set an ON period, push the trippers outwards for the desired duration.
  2. To set an OFF period, leave the trippers in their inward position for the desired duration.
  3. Ensure that the trippers are firmly set in their respective positions (in or out).
  4. For models with a skipper wheel (if applicable), operations can be omitted on selected days of the week. Refer to the specific instructions for skipper wheel adjustment if your model includes this feature.

Substituição manual

The time switch may include a manual override lever. Consult the specific product diagram for its location and operation. This allows for temporary ON/OFF control without affecting the programmed schedule.

Manutenção

  • The Intermatic T1906 is designed for minimal maintenance.
  • Periodically inspect the enclosure for any signs of damage or corrosion.
  • Certifique-se de que todas as conexões de fiação permaneçam seguras.
  • Keep the internal components free from dust and debris.
  • Do not lubricate any internal parts.

Solução de problemas

ProblemaPossível causaSolução
Time switch does not operate.No power supply; incorrect wiring; faulty motor.Check circuit breaker and power connections. Verify wiring against diagram. If motor is faulty, contact Intermatic support.
A carga não liga/desliga nos horários programados.Trippers incorrectly set; time dial not set to current time; faulty switch mechanism.Ensure trippers are pushed in/out firmly. Verify current time setting. Check for obstructions to the switch lever.
Motor hums but dial does not turn.Obstruction in gear train; motor issue.Disconnect power and inspect for obstructions. If problem persists, contact Intermatic support.

If troubleshooting steps do not resolve the issue, contact Intermatic customer support or a qualified electrician.

Especificações

  • Modelo: T1906
  • Tipo: 24-Hour SPDT Time Switch
  • Volumetage: 208-277 Volts
  • Gabinete: 3R Indoor Steel Enclosure
  • Dimensões (Produto): Aproximadamente 5.5 x 3.5 x 8.25 polegadas
  • Peso: Aproximadamente 2 libras
  • Maximum Operations: 96 (48 ON / 48 OFF) per 24 hours
  • Minimum ON/OFF Time: 15 minutos
  • Material: Aço
  • Certificação: CSA (Canadá e EUA)

Informações de garantia

For detailed warranty information, please refer to the manufacturer's official documentation or visit the Intermatic webOs termos da garantia normalmente cobrem defeitos de materiais e de fabricação por um período específico a partir da data da compra.

Suporte ao cliente

For technical assistance, replacement parts, or further inquiries, please contact Intermatic customer support. You can find contact information on the official Intermatic website ou através do revendedor do produto.

Intermatic Website: www.intermatic.com

Documentos relacionados - T1906

Préview Interruptor horário de discagem de 24 horas Intermatic T105: Guia de instalação, fiação e operação
Guia completo para o interruptor horário mecânico de discagem de 24 horas Intermatic T105. Abrange as especificações do modelo, avisos de segurança, instruções de fiação para várias configurações (SPNO, SPNC, SPDT), procedimentos de programação e operação manual. Inclui uma tabela detalhada de especificações elétricas e recomendações de bitola de fio.
Préview Guia de Instalação e Operação do Temporizador de Intervalo de Mola Intermatic
Guia detalhado de instalação, operação e aplicação para temporizadores de intervalo com mola da Intermatic (modelos FF e FD). Inclui especificações dos interruptores, diagramas de fiação e informações sobre a garantia.
Préview Manual de Instruções do Interruptor Temporizador Eletrônico Intermatic GMXFM1
Manual de instruções do interruptor horário eletrônico Intermatic GMXFM1, abrangendo precauções de segurança, símbolos, configuração inicial, programação, ajustes de tempo, ajustes de horário de verão, modos de operação e informações sobre a garantia.
Préview Interruptor de parede interno com temporizador Intermatic EJ351: Guia de instalação, programação e solução de problemas
Guia completo para instalação, programação e resolução de problemas do temporizador de parede interno Intermatic EJ351. Aprenda a definir programações, usar os modos automático e manual e solucionar problemas comuns.
Préview Temporizador de parede Intermatic série KM2: Instruções de instalação e operação
Guia completo para instalação e operação dos temporizadores de parede da série KM2 da Intermatic. Saiba mais sobre recursos, especificações, programação e fiação para controle automático de iluminação e outros circuitos.
Préview Controlador de Temporizador Eletrônico Intermatic ET8215C - Dados Técnicos
Especificações técnicas detalhadas do Controlador de Temporizador Eletrônico Intermatic ET8215C, um controlador eletrônico astronômico de 7 dias e 2 circuitos, adequado para aplicações de 120-277 VCA em uma caixa metálica para uso interno.