1. Introdução

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Wilo 4105032 Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump. This pump is designed for use in hot-water heating systems, industrial circulation systems, cold-water systems, and air-conditioning systems. It is not approved for use with domestic hot water. The pump features a bronze volute and a wet rotor design.

2. Informações de segurança

Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in personal injury, property damage, or electric shock.

  • Segurança elétrica: Ensure the power supply is disconnected before any installation or maintenance work. All electrical connections must be performed by a qualified electrician in accordance with local and national electrical codes. The pump operates on 115-Volt, 60Hz power.
  • Segurança contra pressão: The maximum working pressure for this pump is 145 PSI. Do not exceed this pressure.
  • Segurança de temperatura: The pump is designed for a temperature range of 14°F to 230°F. Ensure system temperatures remain within this range.
  • Instalação: The pump can be installed in any position where the shaft is horizontal. Improper installation can lead to malfunction or damage.
  • Em geral: Do not operate the pump dry. Ensure the system is filled with fluid before starting.

3. Produto acabadoview

The Wilo Star S 21F is a three-speed circulating pump designed for hydronic systems. It features a robust construction and a user-selectable speed setting to optimize performance and energy consumption.

Wilo Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump
An image showing the Wilo Star S 21F circulating pump. The pump is green with a black electrical connection box and a red speed selector switch. The label on the pump body displays model information and technical specifications.

Componentes principais:

  • Carcaça da bomba: Green-colored body, typically bronze volute.
  • Motor: Wet rotor design, 115-Volt, 60Hz.
  • Interruptor seletor de velocidade: Red rotary switch on the electrical box for selecting one of three speeds.
  • Electrical Connection Box: Black enclosure for wiring connections.
  • Flange Connections: Standard connections for system integration.

4. Configuração e instalação

A instalação correta é crucial para o desempenho e a vida útil da bomba.

  1. Preparação do sistema: Ensure the heating or cooling system is drained and clean before installation.
  2. Posição de montagem: The pump can be installed in any position, provided the motor shaft remains horizontal. This is critical for proper lubrication and cooling of the wet rotor.
  3. Conexões de tubulação: The pump uses 3/4-inch to 1-1/2-inch standard flanges. Use appropriate gaskets (typically supplied with the pump) and ensure a watertight seal. Avoid overtightening the flange bolts.
  4. Fiação elétrica:
    • Disconnect power at the main breaker before beginning any wiring.
    • Open the electrical connection box.
    • The pump features quick and easy wire connectors. To insert wires, displace the white tabs 90 degrees to open the holes. Insert the stripped wires and then return the tabs to their original position to secure the connection.
    • Connect the pump to a dedicated 115-Volt, 60Hz circuit. Ensure proper grounding.
    • Close the electrical connection box securely.
  5. Preenchimento do sistema: After installation, slowly fill the system with fluid, ensuring all air is purged from the pump and piping. Air in the system can cause noise and damage to the pump.

5. Instruções de operação

The Wilo Star S 21F pump offers three selectable speeds to match system requirements.

  1. Ligar: Once the pump is installed and the system is filled, restore power to the circuit.
  2. Seleção de velocidade: Locate the red rotary switch on the electrical connection box. This switch allows you to select one of three operating speeds:
    • Velocidade 1 (Eco): Lowest power consumption (55W), suitable for minimal flow requirements.
    • Velocidade 2: Medium power consumption (77W), for moderate flow.
    • Speed 3 (Max): Highest power consumption (98W), for maximum flow and head.
    Rotate the switch to the desired speed setting. The pump will begin operation at the selected speed.
  3. Monitoramento: Observe the system for proper circulation and listen for any unusual noises.

6. Manutenção

The Wilo Star S 21F is designed for minimal maintenance. However, periodic checks can ensure optimal performance and extend its lifespan.

  • Inspeção anual: Annually inspect the pump for any signs of leaks, corrosion, or unusual wear.
  • Qualidade do fluido do sistema: Ensure the system fluid is clean and free of debris. Contaminants can reduce pump efficiency and lifespan.
  • Conexões elétricas: Periodically check electrical connections for tightness and signs of overheating. Disconnect power before checking.
  • Purga de ar: If the pump becomes noisy, it may indicate air in the system. Follow system-specific procedures to purge air.

7. Solução De Problemas

Consulte a tabela abaixo para obter informações sobre problemas comuns e suas possíveis soluções.

ProblemaPossível causaSolução
A bomba não iniciaNo power; faulty wiring; seized impellerCheck power supply and circuit breaker. Verify electrical connections. Consult a qualified technician if impeller is seized.
Bomba faz barulhoAir in system; cavitation; foreign object in pumpPurge air from the system. Check system pressure. Inspect pump for obstructions (disconnect power first).
Fluxo insuficienteIncorrect speed setting; air in system; clogged filter; undersized pumpIncrease speed setting. Purge air. Check and clean system filters. Verify pump sizing for application.
A bomba está vazandoLoose connections; damaged gaskets; cracked housingTighten flange connections. Replace damaged gaskets. If housing is cracked, pump replacement may be necessary.

8. Especificações

EspecificaçãoValor
MarcaWilo
Número do modelo4105032 (Typ Star S 21 FX)
Volumetage115 Volts
Freqüência60 Hz
Corrente máxima (I máx.)0.70 UMA
Consumo de energia (W)Speed 3: 98W, Speed 2: 77W, Speed 1: 55W
Taxa de fluxo máxima21 galões por minuto
Altura máxima de elevação (cabeça)21 pés
Faixa de temperatura14°F a 230°F (-10°C a 110°C)
Pressão Máxima de Trabalho145 PSI
MaterialStainless Steel (shaft), Bronze (volute)
Peso do item7.08 libras (3.22 kg)
Tamanho do flange3/4-Inch - 1-1/2-Inch standard flange
Classe de gabineteCSA enclosure 2
Classe de isolamentoClasse F

9. Garantia e Suporte

Wilo provides a 3-year limited warranty from the date of purchase for Residential Business Services products. For warranty claims, technical support, or further assistance, please contact Wilo customer service or your authorized dealer.

Documentos relacionados - 4105032

Préview Instruções de instalação e operação da bomba de circulação Wilo-Star RS, RSD, ST, RSG, AC
Instruções abrangentes de instalação e operação para bombas de circulação Wilo-Star RS, RSD, ST, RSG, AC, abrangendo informações gerais, segurança, transporte, descrição, montagem, instalação, conexão elétrica, operação, manutenção e solução de problemas.
Préview Circuladores de rotor úmido residenciais Wilo Star: Instruções de instalação e operação
Manual completo de instalação e operação para circuladores de rotor úmido residenciais Wilo Star. Abrange segurança, dados técnicos, instalação, conexão elétrica, inicialização, manutenção e solução de problemas.
Préview Instruções de instalação e operação do Wilo-Star RS, RSD, ST, RSG, AC
Guia completo para instalação, operação e manutenção de bombas de circulação Wilo-Star RS, RSD, ST, RSG e AC. Abrange segurança, especificações técnicas, montagem, conexão elétrica, operação, solução de problemas e peças de reposição.
Préview Instruções de Instalação e Operação do Wilo-Star-Z 15
This document provides comprehensive installation, operation, and maintenance guidance for the Wilo-Star-Z 15 circulating pump. It includes safety warnings, technical specifications, intended use, troubleshooting steps, and contact information for Wilo USA and Wilo Canada.
Préview Instruções de instalação e operação da bomba de circulação Wilo-Star RS, RSD, ST, RSG, AC
Manual completo de instalação e operação das bombas de circulação Wilo-Star das séries RS, RSD, ST, RSG e AC. Abrange informações gerais, normas de segurança, transporte, armazenamento, descrição da bomba, acessórios, montagem, conexão elétrica, operação, manutenção, solução de problemas e peças de reposição.
Préview Wilo-Star-Z/-ZD Einbau- und Betriebsanleitung
Instalações completas e garantia de segurança para as bombas de zirculação Wilo-Star-Z/-ZD, inclusive Sicherheitshinweisen, dados técnicos e garantias de segurança.