The Fluke 355 digital clamp-meter is a true RMS sensing, auto-ranging multimeter designed for precise measurement of current, voltage, frequency, and resistance in various electrical testing applications. It features a robust clamp mechanism for non-contact current measurement and a comprehensive set of functions for professional use, ensuring accurate readings for both linear and non-linear loads.
Informações de segurança
Always adhere to safety precautions when working with electrical equipment. This device is designed to meet IEC safety standard 61010-2-032.
- CAT IV, 600V: Suitable for measurements at the source of the low-voltage installation, such as electricity meters and primary over-current protection equipment.
- CAT III, 1,000V: Suitable for measurements within fixed installations, including switches and industrial equipment permanently connected to the fixed installation.
Ensure proper personal protective equipment (PPE) is used, and always follow local safety regulations when operating this device.
O que está na caixa
Your Fluke 355 Clamp-Meter package includes the following components:
- Fluke 355 digital clamp-metro
- Conjunto de cabos de teste
- Conjunto de sondas de teste
- Conjunto de clipes de jacaré
- (6) pilhas AA
- Maleta de transporte
- Manual do usuário

Image: All components included with the Fluke 355 Clamp-Meter, neatly arranged.
Características do produto
- Detecção True RMS: Provides accurate readings for both linear and non-linear loads, regardless of waveform.
- Medição de alta corrente: Measures AC and DC current up to 2,000A (1,400A AC RMS).
- Large Jaw Opening: 58mm (2.3 inches) jaw opening accommodates large or multiple conductors for non-contact current measurement.
- Volumetage Medição: Mede AC voltage até 600V e DC voltage até 1,000V.
- Frequency and Resistance: Measures frequency up to 1kHz and resistance up to 400kΩ.
- Inrush Current Function: Analyzes surge current during motor startup and other inductive loads for stable measurements.
- Filtro passa-baixa: Reduces high-frequency interference for accurate measurements of complex waveforms.
- Função Mín/Máx: Toggles to display lowest, highest, and average readings.
- Dados em espera: Freezes the reading on the display for easy documentation in tight spaces.
- Sinalizador de continuidade: Confirms electrical continuity.
- LCD retroiluminado: Improves visibility in low-light conditions, with automatic backlight shut-off.
- Desligamento automático: Conserves battery life by automatically turning off after 20 minutes of non-use.
- Indicador de bateria fraca: Signals when batteries need replacement.
Configurar
Instalação da bateria
The Fluke 355 requires six 1.5V AA batteries for operation. These are typically included with your purchase.
- Localize a tampa do compartimento da bateria na parte traseira do dispositivo.
- Use uma chave de fenda para abrir a tampa.
- Insert the six AA batteries, ensuring correct polarity (+/-).
- Recoloque a tampa do compartimento da bateria e fixe-a.
Inspeção Inicial
Before first use, inspect the clamp-meter, test leads, and accessories for any signs of damage. Do not use the device if any damage is observed.
Instruções de operação
Ligar/desligar
Turn the rotary switch to any measurement function to power on the device. Turn the rotary switch to "OFF" to power off. The device will automatically power off after 20 minutes of inactivity to conserve battery life.
Measuring AC/DC Current (Clamp Função)
- Turn the rotary switch to the "A AC+DC" position.
- Press the jaw release lever to open the clamp mandíbulas.
- Posicione o clamp jaws around a single conductor. Ensure the jaws are fully closed.
- Leia o valor atual no LCD.

Image: The clamp jaws of the Fluke 355 securely closed around an electrical conductor for current measurement.
Vol de mediçãotage (CA/CC)
- Connect the test leads to the appropriate input jacks (COM and V).
- Turn the rotary switch to the "V AC+DC" position.
- Conecte as pontas de prova ao circuito ou componente a ser medido.
- Leia o vol.tage valor no LCD.
Medição de resistência (Ω)
- Connect the test leads to the appropriate input jacks (COM and Ω).
- Gire a chave rotativa para a posição "Ω".
- Certifique-se de que o circuito esteja desenergizado antes de medir a resistência.
- Conecte as pontas de prova ao componente que deseja medir.
- Leia o valor da resistência no visor LCD.
Outras funções
- ALCANCE: Manually select the measurement range if auto-ranging is not desired.
- ESPERA: Pressione para congelar a leitura atual no visor. Pressione novamente para liberar.
- ZERO: Used to zero out DC current readings or resistance readings for lead compensation.
- Hz: Measures frequency.
- INVOCAÇÃO: Measures the peak current during motor startup.
- MIN MAX: Toggles through minimum, maximum, and average readings captured during a measurement session.
- FILTRO: Activates a low-pass filter to reduce electrical noise for stable readings.

Imagem: Detalhada view of the Fluke 355 Clamp-Meter's display and control panel.
Manutenção
Limpeza
Limpe o medidor casing com anúncioamp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and dry.
Substituição da bateria
When the low-battery indicator appears on the display, replace all six AA batteries promptly to ensure accurate measurements. Follow the battery installation steps outlined in the Setup section.
Armazenar
Armazene o clamp-meter in its soft carrying case in a dry, dust-free environment when not in use. Remove batteries if storing for extended periods to prevent leakage.
Solução de problemas
If the Fluke 355 Clamp-Meter is not functioning as expected, consider the following:
- Sem tela/energia: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary. Ensure the rotary switch is not in the "OFF" position.
- Leituras imprecisas: Verify that the correct measurement function is selected. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
- Continuity Buzzer Not Working: Ensure the device is in the continuity measurement mode and the circuit is de-energized.
For persistent issues, refer to the official Fluke support resources or contact customer service.
Especificações
| Parâmetro | Valor |
|---|---|
| Entrada de corrente CA máxima | 2,000A (1,400A RMS) |
| Maximum DC Current Input | 2,000A |
| Vol AC Máximotage entrada | 600V |
| Vol CC Máximotage entrada | 1,000V |
| Maximum Frequency Detected | 1kHz |
| Resistência máxima detectada | 400kΩ |
| Avaliação de instalação | CAT IV, 600V; CAT III, 1,000V |
| Padrões atendidos | IEC safety standard 61010-2-032; CE marking; CSA; Australia N10140 |
| Fonte de energia | (6) pilhas AA de 1.5 V |
| Peso | 0.814 kg / 1.8 lb |
| Dimensões (A x L x P) | 300 x 98 x 52 mm / 12 x 3.75 x 2 polegadas |
| Abertura da mandíbula | 58 mm (2.3 polegadas) |
| Desligamento automático | 20 minutos |
| Mostrar | LCD com luz de fundo |
| RMS verdadeiro | Sim |
| Intervalo Automático | Sim |
| Fabricante | Corporação Fluke |
| Número do modelo | FLUKE-355 |
| UPC | 095969401203, 785577871016 |
Garantia e Suporte
Fluke Corporation provides high-quality testing tools. For warranty information, technical support, or service, please visit the official Fluke website ou entre em contato com o departamento de atendimento ao cliente.
Você pode encontrar mais informações e recursos de suporte em Loja Fluke na Amazon.