Fluke FLUKE-355

Fluke 355 True RMS ClampManual do Usuário do Medidor

Modelo: FLUKE-355

Introdução

The Fluke 355 digital clamp-meter is a true RMS sensing, auto-ranging multimeter designed for precise measurement of current, voltage, frequency, and resistance in various electrical testing applications. It features a robust clamp mechanism for non-contact current measurement and a comprehensive set of functions for professional use, ensuring accurate readings for both linear and non-linear loads.

Informações de segurança

Always adhere to safety precautions when working with electrical equipment. This device is designed to meet IEC safety standard 61010-2-032.

  • CAT IV, 600V: Suitable for measurements at the source of the low-voltage installation, such as electricity meters and primary over-current protection equipment.
  • CAT III, 1,000V: Suitable for measurements within fixed installations, including switches and industrial equipment permanently connected to the fixed installation.

Ensure proper personal protective equipment (PPE) is used, and always follow local safety regulations when operating this device.

O que está na caixa

Your Fluke 355 Clamp-Meter package includes the following components:

  • Fluke 355 digital clamp-metro
  • Conjunto de cabos de teste
  • Conjunto de sondas de teste
  • Conjunto de clipes de jacaré
  • (6) pilhas AA
  • Maleta de transporte
  • Manual do usuário
Contents of the Fluke 355 Clamp-Meter package laid out, including the meter, test leads, alligator clips, soft carrying case, and user manual.

Image: All components included with the Fluke 355 Clamp-Meter, neatly arranged.

Características do produto

  • Detecção True RMS: Provides accurate readings for both linear and non-linear loads, regardless of waveform.
  • Medição de alta corrente: Measures AC and DC current up to 2,000A (1,400A AC RMS).
  • Large Jaw Opening: 58mm (2.3 inches) jaw opening accommodates large or multiple conductors for non-contact current measurement.
  • Volumetage Medição: Mede AC voltage até 600V e DC voltage até 1,000V.
  • Frequency and Resistance: Measures frequency up to 1kHz and resistance up to 400kΩ.
  • Inrush Current Function: Analyzes surge current during motor startup and other inductive loads for stable measurements.
  • Filtro passa-baixa: Reduces high-frequency interference for accurate measurements of complex waveforms.
  • Função Mín/Máx: Toggles to display lowest, highest, and average readings.
  • Dados em espera: Freezes the reading on the display for easy documentation in tight spaces.
  • Sinalizador de continuidade: Confirms electrical continuity.
  • LCD retroiluminado: Improves visibility in low-light conditions, with automatic backlight shut-off.
  • Desligamento automático: Conserves battery life by automatically turning off after 20 minutes of non-use.
  • Indicador de bateria fraca: Signals when batteries need replacement.

Configurar

Instalação da bateria

The Fluke 355 requires six 1.5V AA batteries for operation. These are typically included with your purchase.

  1. Localize a tampa do compartimento da bateria na parte traseira do dispositivo.
  2. Use uma chave de fenda para abrir a tampa.
  3. Insert the six AA batteries, ensuring correct polarity (+/-).
  4. Recoloque a tampa do compartimento da bateria e fixe-a.

Inspeção Inicial

Before first use, inspect the clamp-meter, test leads, and accessories for any signs of damage. Do not use the device if any damage is observed.

Instruções de operação

Ligar/desligar

Turn the rotary switch to any measurement function to power on the device. Turn the rotary switch to "OFF" to power off. The device will automatically power off after 20 minutes of inactivity to conserve battery life.

Measuring AC/DC Current (Clamp Função)

  1. Turn the rotary switch to the "A AC+DC" position.
  2. Press the jaw release lever to open the clamp mandíbulas.
  3. Posicione o clamp jaws around a single conductor. Ensure the jaws are fully closed.
  4. Leia o valor atual no LCD.
Fluke 355Clamp-Meter with its jaws clamped around a thick electrical cable, demonstrating current measurement.

Image: The clamp jaws of the Fluke 355 securely closed around an electrical conductor for current measurement.

Vol de mediçãotage (CA/CC)

  1. Connect the test leads to the appropriate input jacks (COM and V).
  2. Turn the rotary switch to the "V AC+DC" position.
  3. Conecte as pontas de prova ao circuito ou componente a ser medido.
  4. Leia o vol.tage valor no LCD.

Medição de resistência (Ω)

  1. Connect the test leads to the appropriate input jacks (COM and Ω).
  2. Gire a chave rotativa para a posição "Ω".
  3. Certifique-se de que o circuito esteja desenergizado antes de medir a resistência.
  4. Conecte as pontas de prova ao componente que deseja medir.
  5. Leia o valor da resistência no visor LCD.

Outras funções

  • ALCANCE: Manually select the measurement range if auto-ranging is not desired.
  • ESPERA: Pressione para congelar a leitura atual no visor. Pressione novamente para liberar.
  • ZERO: Used to zero out DC current readings or resistance readings for lead compensation.
  • Hz: Measures frequency.
  • INVOCAÇÃO: Measures the peak current during motor startup.
  • MIN MAX: Toggles through minimum, maximum, and average readings captured during a measurement session.
  • FILTRO: Activates a low-pass filter to reduce electrical noise for stable readings.
Frente view of the Fluke 355 Clamp-Meter, showing its large digital display, rotary switch, and function buttons.

Imagem: Detalhada view of the Fluke 355 Clamp-Meter's display and control panel.

Manutenção

Limpeza

Limpe o medidor casing com anúncioamp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and dry.

Substituição da bateria

When the low-battery indicator appears on the display, replace all six AA batteries promptly to ensure accurate measurements. Follow the battery installation steps outlined in the Setup section.

Armazenar

Armazene o clamp-meter in its soft carrying case in a dry, dust-free environment when not in use. Remove batteries if storing for extended periods to prevent leakage.

Solução de problemas

If the Fluke 355 Clamp-Meter is not functioning as expected, consider the following:

  • Sem tela/energia: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary. Ensure the rotary switch is not in the "OFF" position.
  • Leituras imprecisas: Verify that the correct measurement function is selected. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
  • Continuity Buzzer Not Working: Ensure the device is in the continuity measurement mode and the circuit is de-energized.

For persistent issues, refer to the official Fluke support resources or contact customer service.

Especificações

ParâmetroValor
Entrada de corrente CA máxima2,000A (1,400A RMS)
Maximum DC Current Input2,000A
Vol AC Máximotage entrada600V
Vol CC Máximotage entrada1,000V
Maximum Frequency Detected1kHz
Resistência máxima detectada400kΩ
Avaliação de instalaçãoCAT IV, 600V; CAT III, 1,000V
Padrões atendidosIEC safety standard 61010-2-032; CE marking; CSA; Australia N10140
Fonte de energia(6) pilhas AA de 1.5 V
Peso0.814 kg / 1.8 lb
Dimensões (A x L x P)300 x 98 x 52 mm / 12 x 3.75 x 2 polegadas
Abertura da mandíbula58 mm (2.3 polegadas)
Desligamento automático20 minutos
MostrarLCD com luz de fundo
RMS verdadeiroSim
Intervalo AutomáticoSim
FabricanteCorporação Fluke
Número do modeloFLUKE-355
UPC095969401203, 785577871016

Garantia e Suporte

Fluke Corporation provides high-quality testing tools. For warranty information, technical support, or service, please visit the official Fluke website ou entre em contato com o departamento de atendimento ao cliente.

Você pode encontrar mais informações e recursos de suporte em Loja Fluke na Amazon.

Documentos relacionados - FLUKE-355

Préview Fluke 381 Display Remoto True-rms Clamp Manual do usuário do medidor
Manual do usuário completo para o display remoto Fluke 381 True-rms Clamp Medidor. Abrange as características do produto e os procedimentos de medição de corrente CA/CC e tensão.tage, resistência, frequência, corrente de pico, manutenção, especificações e informações de segurança. Inclui descrições detalhadas de diagramas e tabelas.
Préview Fluke 373 True-RMS CA Clamp Medidor - Especificações Técnicas e Maisview
Dados técnicos detalhados, principais características, visão geral do produtoviewEspecificações e informações para encomenda do multímetro Fluke 373 True-RMS AC Cl.amp Medidor projetado para medições de corrente alternada (CA) de até 600 A.
Préview Fluke 323/324/325 Clamp Manual do Usuário do Medidor - Especificações e Segurança
Manual do usuário completo para os modelos Fluke 323, 324 e 325 Cl.amp Medidores. Inclui informações de segurança, especificações elétricas e mecânicas e instruções de operação.
Préview Fluke 305Clamp Manual do usuário do medidor
Manual do usuário para o Fluke 305 Clamp Medidor que fornece informações detalhadas de segurança, especificações do produto e orientações operacionais para medições elétricas precisas.
Préview Fluke 370 FC Series True-RMS Wireless AC/DC Clamp Manual do Usuário e Especificações dos Medidores
Manual do usuário completo e especificações técnicas para o multímetro sem fio True-RMS AC/DC da série Fluke 370 FC.amp Medidores, incluindo os modelos 374 FC, 375 FC e 376 FC. Características, funcionalidades, tabelas comparativas e informações para encomenda.
Préview Multímetros digitais de bolso Fluke 106/107: especificações técnicas e recursos
Especificações técnicas detalhadas, destaques do produto e informações gerais sobre os multímetros digitais compactos Fluke 106 e 107. Saiba mais sobre suas especificações elétricas, precisão, recursos e acessórios inclusos.