YASKAWA CIMR-VU4A0011FAA

Manual do Usuário do Inversor de Frequência CA Série V1000 da YASKAWA

Model: CIMR-VU4A0011FAA

Introdução

This manual provides essential information for the safe and effective use of the YASKAWA V1000 Series AC Drive, model CIMR-VU4A0011FAA. The V1000 is a compact, high-performance variable frequency drive designed for a wide range of industrial applications, offering precise motor control and energy efficiency. Please read this manual thoroughly before installation, operation, or maintenance.

Yaskawa V1000 AC Drive, main view

Figure 1: Yaskawa V1000 AC Drive, showing the main unit with its grey casing and heat sink fins.

Informações de segurança

Always observe the following safety precautions to prevent injury, damage to equipment, or property loss. This drive contains high voltage components and should only be handled by qualified personnel.

Configurar

1. Desembalagem e Inspeção

Carefully remove the drive from its packaging. Inspect the unit for any signs of damage that may have occurred during shipping. Verify that all components listed in the packing list are present.

Yaskawa V1000 AC Drive with instruction manual

Figure 2: The Yaskawa V1000 AC Drive unit shown alongside its accompanying instruction manual, still in its plastic packaging.

2. Montagem

Mount the drive vertically on a flat, stable surface. Ensure adequate clearance for ventilation around the unit. Refer to the dimensions provided in the specifications section for proper spacing. Avoid mounting in direct sunlight or near heat sources.

3. Fiação

All wiring must comply with national and local electrical codes. Use appropriate wire gauges for power, motor, and control circuits. Ensure proper grounding of the drive chassis and motor frame.

Fundo view of Yaskawa V1000 AC Drive

Figura 3: Parte inferior view of the Yaskawa V1000 AC Drive, showing the heat sink fins and mounting points, crucial for proper ventilation and installation.

4. Inicialização

Before applying power, double-check all wiring connections. Ensure no loose wires or foreign objects are present. Apply power and observe the drive's display. The drive should power on and display its default status or a ready message.

Operacional

1. Operação básica

The V1000 drive can be operated via its built-in keypad, external control terminals, or serial communication. For basic operation using the keypad:

  1. Pressione o CORRER botão para ligar o motor.
  2. Pressione o PARAR botão para parar o motor.
  3. Use o PARA CIMA/PARA BAIXO arrow keys to adjust the output frequency (motor speed) if in frequency reference mode.

2. Configurações de Parâmetros

The drive's behavior is configured through various parameters. Access the parameter menu via the keypad. Key parameters include:

Refer to the comprehensive parameter list in the full YASKAWA V1000 technical manual for detailed descriptions and settings.

Manutenção

Regular maintenance ensures optimal performance and extends the lifespan of your V1000 AC Drive. Always disconnect power before performing any maintenance.

Solução de problemas

This section provides guidance for common issues. For detailed fault codes and advanced troubleshooting, consult the full YASKAWA V1000 technical manual.

SintomaPossível causaAção corretiva
O drive não liga.Sem alimentação de energia; Fusível queimado; Falha internaCheck power supply; Inspect fuses; Contact support if internal fault suspected.
O motor não funcionaIncorrect wiring; Parameter settings; External stop signal activeVerify wiring (motor/control); Check parameter settings (e.g., frequency reference, run command source); Ensure no active stop signals.
Overcurrent fault (OC)Motor overload; Short circuit in motor/cables; Rapid acceleration/decelerationCheck motor load; Inspect motor and cables for damage; Increase acceleration/deceleration times.
Sobrevoltage falha (OV)Energia regenerativa do motor; Alta tensão de entradatageIncrease deceleration time; Install braking resistor if necessary; Verify input voltage.

Especificações

Key technical specifications for the YASKAWA V1000 AC Drive, model CIMR-VU4A0011FAA:

ParâmetroValor
Número do modeloCIMR-VU4A0011FAA
Vol de entradatageAC 3-Phase 380-480V
Frequência de entrada50/60 Hz
Input Current (Rated)14.0A (380V) / 10.4A (480V)
Volume de saídatageAC 3-Phase 0-480V
Faixa de Frequência de saída0-400 Hz
Output Current (Rated)11.1A (380V) / 9.2A (480V)
Mass / Weight2.6 kg (aprox. 5.73 lbs)
Classificação do gabineteIP20
FabricanteYASKAWA
País de origemJapão
ASINB008HQ5TP0
Product label of Yaskawa V1000 AC Drive showing model and electrical specifications

Figure 4: Detailed product label of the Yaskawa V1000 AC Drive, displaying the model number, input/output electrical ratings, and manufacturing information.

Garantia e Suporte

YASKAWA products are manufactured to high standards and typically come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty documentation included with your purchase or visit the official YASKAWA website.

For technical support, service, or to inquire about replacement parts, please contact YASKAWA customer service or an authorized YASKAWA distributor. Provide your product model number (CIMR-VU4A0011FAA) and serial number when seeking assistance.

You can find more information and contact details on the official YASKAWA website: www.yaskawa.com

Documentos relacionados - CIMR-VU4A0011FAA

Préview Inversor CA YASKAWA L1000A: Guia de início rápido para aplicações em elevadores
Este Guia de Início Rápido do Inversor de Frequência CA Yaskawa L1000A fornece informações essenciais para a instalação, fiação e configuração inicial seguras e eficazes de inversores de frequência para aplicações em elevadores. Ele aborda precauções críticas de segurança, instalação mecânica e elétrica, operação do teclado e procedimentos de inicialização.
Préview Guia de Início Rápido do Inversor de Frequência YASKAWA A1000
Quick Start Guide for the YASKAWA AC Drive A1000 series, a high-performance vector control drive. This manual provides essential information for safe installation, wiring, initial setup, operation, and troubleshooting of industrial AC drives.
Préview Manual de comunicação Modbus dos inversores Yaskawa V7 e V74X
Guia para comunicação Modbus para inversores de frequência Yaskawa V7 e V74X, abrangendo configuração de rede (RS-232, RS-422, RS-485), acesso a parâmetros, formatos de mensagens e solução de problemas para automação industrial.
Préview Suplemento de software personalizado de alta frequência Yaskawa AC Drive - A1000
Este documento complementa o Guia de Início Rápido e o Manual Técnico do Yaskawa A1000, detalhando modificações e novas funções para o Software Personalizado de Alta Frequência. Ele abrange alterações em parâmetros, funções e notas de aplicação para aplicações de motores de alta velocidade.
Préview Manual do usuário do inversor de frequência Yaskawa Z1000 para aplicações em ventiladores e bombas de sistemas HVAC.
This comprehensive user manual provides detailed instructions for the Yaskawa Z1000 AC Drive, covering installation, setup, programming, operation, and troubleshooting for HVAC fan and pump applications. It includes specifications for 200V and 400V classes.
Préview Guia de transição do inversor de frequência CA Yaskawa V1000 para GA500
Um guia completo para OEMs, integradores e usuários finais que estão migrando de inversores de frequência da série Yaskawa V1000 para os inversores de frequência Yaskawa GA500. Este documento aborda a identificação do modelo, seleção do inversor, dimensões, fiação e proteção do circuito de derivação.