Einhell GC-DP 1340 G

Einhell GC-DP 1340 G Dirty Water Pump User Manual

Model: GC-DP 1340 G

Marca: Einhell

1. Introdução

The Einhell GC-DP 1340 G dirty water pump is a powerful and robust tool designed for demanding drainage tasks. It is ideal for pumping heavily contaminated water from various sources such as ponds, wells, construction sites, and flooded basements. With a high flow rate and durable construction, this pump ensures efficient and reliable performance.

Einhell GC-DP 1340 G Dirty Water Pump with rope

Figure 1: Einhell GC-DP 1340 G Dirty Water Pump and included rope.

2. Instruções de segurança

Siga sempre as seguintes diretrizes de segurança para evitar ferimentos e danos ao equipamento:

  • Read the entire manual before operating the pump.
  • Ensure the power supply matches the pump's specifications (230 Volts).
  • Não utilize a bomba se o cabo de alimentação ou a ficha estiverem danificados.
  • Never lift or carry the pump by its power cord. Use the transport handle or the provided rope.
  • Mantenha crianças e pessoas não autorizadas afastadas da área de operação.
  • Do not pump flammable, explosive, or corrosive liquids.
  • Ensure adequate ventilation when operating in enclosed spaces.
  • Disconnect the pump from the power supply before any maintenance or cleaning.

3. Componentes do produto

Familiarize yourself with the main components of your Einhell dirty water pump:

  • Close-up of Einhell pump with float switch and hose connection

    3.1. Pump Body and Float Switch

    The main body houses the motor and impeller. The red float switch automatically controls the pump's operation based on water level, allowing for continuous or automatic mode.

  • Close-up of hose connection on the pump

    3.2. Conexão da mangueira

    The G2 hose connection is designed for 2-inch (approximately 50.8mm) hoses, ensuring efficient water discharge.

  • Close-up of the transport handle on top of the pump

    3.3. Alça de transporte

    A sturdy handle is integrated at the top of the pump for easy and secure transportation.

  • Coiled white rope

    3.4. 6-meter Rope

    A 6-meter rope is included to facilitate lowering the pump into deep areas like wells or ponds.

4. Configuração

Follow these steps for proper setup of your dirty water pump:

  1. Anexe a mangueira: Securely connect a 2-inch (50.8mm) discharge hose to the pump's G2 connection. Ensure the connection is tight to prevent leaks.
  2. Posicionamento: Place the pump on a stable, level surface in the area to be drained. Ensure the pump is fully submerged in the water for optimal operation.
  3. Espaço Operacional: Allow for sufficient operating space around the pump, with a minimum of 50 x 50 cm, and a diameter of 27 cm for the pump itself.
  4. Diagram showing minimum operating space for the pump

    Figure 2: Recommended minimum operating space for the pump.

  5. Ajuste do interruptor de nível: Adjust the float switch cable length to control the desired ON/OFF water levels. A shorter cable means the pump will switch on and off within a smaller water level range.
  6. Conexão de energia: Plug the pump into a grounded electrical outlet that matches the pump's voltage requisitos.

5. Instruções de operação

The Einhell GC-DP 1340 G pump can operate in continuous or automatic mode:

5.1. Automatic Operation (Float Switch Controlled)

In automatic mode, the pump starts and stops based on the water level, controlled by the float switch. When the water level rises and lifts the float switch, the pump will activate. When the water level drops and the float switch lowers, the pump will deactivate.

Icon representing an adjustable float switch with ON and OFF states

Figure 3: Adjustable float switch for automatic operation.

5.2. Operação Contínua

For continuous operation, secure the float switch in an upright position (e.g., by attaching it to the pump handle) so that it remains in the "ON" position regardless of the water level. This will keep the pump running continuously until manually unplugged or the water source is depleted.

The pump is designed to handle dirty water with particles up to 40 mm in size.

Icon indicating maximum particle size of 40mm

Figure 4: Maximum particle size handled by the pump.

6. Manutenção

A manutenção regular garante a longevidade e o desempenho ideal da sua bomba:

  • Limpeza: After each use, especially when pumping heavily contaminated water, rinse the pump thoroughly with clean water to remove debris and prevent clogging.
  • Inspeção do impulsor: Periodically check the impeller for any blockages or damage. Clear any debris carefully.
  • Diagram showing the pump's impeller

    Figura 5: interno view of the pump's impeller.

  • Double Mechanical Seal: The high-quality double mechanical seal is designed for excellent durability and requires no maintenance.
  • Diagram showing the double mechanical seal

    Figure 6: Illustration of the double mechanical seal for extended lifespan.

  • Armazenar: Guarde a bomba em local seco e livre de geadas quando não estiver em uso por longos períodos.

7. Solução De Problemas

ProblemaPossível causaSolução
A bomba não arranca.No power supply; Float switch not activated; Motor overload.Check power connection and circuit breaker; Ensure float switch is in "ON" position or water level is sufficient; Allow motor to cool down, then restart.
A bomba funciona, mas não há descarga de água ou o fluxo é baixo.Hose kinked or blocked; Impeller clogged; Airlock in pump.Check and clear hose; Disconnect power and clear impeller; Submerge pump fully, tilt it to release air bubbles, then restart.
A bomba para inesperadamente.Float switch deactivated (water level too low); Thermal overload protection activated.Check water level and float switch position; Allow pump to cool down.

8. Especificações

RecursoEspecificação
ModeloGC-DP 1340 G
Poder1300 Watts
Volumetage230 Volts
Máx. Quociente de vazão23000 litros por hora
Altura máxima da cabeça10 metros
Tamanho Máx. de Partícula40 milímetros
Conexão de mangueiraG2 (2 inches / 50.8mm)
Comprimento do cabo10 metros
Peso19.3 quilos
Dimensões (C x L x A)26 x 19.5 x 51.2 cm
MaterialAço inoxidável, ferro fundido
UsoAr livre
País de origemChina

9. Garantia e Suporte

Einhell products are manufactured with high-quality materials and undergo strict quality controls. While specific warranty details may vary by region and retailer, a standard return policy of 30 days is typically offered for new products.

For technical support, spare parts, or warranty claims, please contact your authorized Einhell dealer or visit the official Einhell website for customer service information. Please have your model number (GC-DP 1340 G) and purchase details ready when contacting support.

Para mais informações, visite o Einhell Brand Store.

Documentos relacionados - GC-DP 1340 G

Préview Einhell GC-DP 3325 Schmutzwasserpumpe Bedienungsanleitung
Originalbetriebsanleitung für die Einhell GC-DP 3325 Schmutzwasserpumpe. Enthält wichtige Sicherheitshinweise, Installationsanleitungen, Bedienung und Wartung.
Préview Einhell GE-DP 18/25 LL Li Akku-Schmutzwasserpumpe Bedienungsanleitung
Entdecken Sie die Einhell GE-DP 18/25 LL Li, eine leistungsstarke Akku-Schmutzwasserpumpe für Haus und Garten. Diese Anleitung bietet detaillierte Informationen zur sicheren Installation, Bedienung und Wartung für optimale Leistung.
Préview Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe / Flutset Bedienungsanleitung
Diese Anleitung beschreibt die Bedienung und Wartung der Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe und des Flutsets. Sie enthält wichtige Sicherheitshinweise, technische Daten und Anleitungen zur Fehlerbehebung für den effizienten Einsatz der Pumpe.
Préview Einhell GC-CL 18 Li E Kit Cordless Leaf Blower: User Manual & Instructions
Instructions for use and overview of the Einhell GC-CL 18 Li E Kit Cordless Leaf Blower. Learn about product features, package contents, safety guidelines, device operation, charging, maintenance, troubleshooting, and specifications for this 18V Power X-Change system tool.
Préview Einhell GC-SC 18/28 Li Akku-Vertikutierer und Rasenlüfter Bedienungsanleitung
Die offizielle Bedienungsanleitung für den Einhell GC-SC 18/28 Li Akku-Vertikutierer und Rasenlüfter. Enthält Sicherheitshinweise, Bedienung, Wartung und Fehlerbehebung für Ihr Gartengerät.
Préview Einhell GC-ET 4530 Elektro-Rasentrimmer - Bedienungsanleitung
Umfassende Bedienungsanleitung para o Einhell GC-ET 4530 Elektro-Rasentrimmer. Enthält Sicherheitshinweise, segunda-feiratage-, Betriebs-, Wartungs- e Fehlerbehebungsinformationen.