Produto acimaview
The Brecknell SBWLPS400 Portable Shipping Scale is designed for accurate weighing in shipping, warehouse, and general-purpose applications. It features a robust four-load cell design, ensuring precise measurements up to 400 lb. This scale offers dual power modes for both portability and permanent installation, making it versatile for various environments. Its compatibility with major shipping software, including UPS, streamlines your workflow.
The large, easy-to-read LCD display can be wall-mounted or desk-mounted for optimal visibility, and its large keyboard switches are designed for ease of use, even with gloved hands. An RS232 link and PC Serial Interface Cable are included for seamless computer integration.
Guia de configuração
1. Desembalagem e verificação do conteúdo
Retire cuidadosamente todos os componentes da embalagem. Certifique-se de que os seguintes itens estejam presentes:
- Plataforma de pesagem
- Unidade Indicadora
- Cabo RS-232
- 4 pilhas AAA
- Mounting Bracket (for indicator)
- Manual de Instruções (este documento)

Figure 1: Included components of the Brecknell SBWLPS400 Portable Shipping Scale. This image shows the weighing platform, the digital indicator, connecting cables, and the AAA batteries required for operation.
2. Alimentando a balança
The scale can be powered using the included AAA batteries or an optional AC adapter (not included). For battery operation, open the battery compartment on the indicator unit and insert the 4 AAA batteries, observing polarity.
For continuous operation or when connecting to a computer, it is recommended to use an AC adapter (DC 6V, 500mA, center positive) plugged into the power input port on the indicator unit.
3. Conectando componentes
Connect the weighing platform to the indicator unit using the coiled cable. Ensure the connector is securely inserted into the designated port on the indicator.
The indicator unit can be placed on a desk or mounted on a wall using the provided bracket for optimal viewe acessibilidade.

Figura 2: Example setup of the Brecknell SBWLPS400 scale in a typical shipping environment. The weighing platform is on the floor, and the indicator is conveniently mounted on a wall for easy reading.
Instruções de operação
1. Pesagem Básica
- Coloque a balança em uma superfície firme e nivelada.
- Pressione o LIGADO/DESLIGADO/ZERO button to power on the scale. The display will show "0.00" when ready.
- Coloque o objeto a ser pesado no centro da plataforma de pesagem.
- Leia o peso exibido na tela LCD.
2. Using the Display and Buttons
The indicator unit features a clear LCD display and several function buttons:
- ON/OFF/ZERO: Powers the scale on or off, and zeros the display.
- UNIDADES: Toggles between available weight units (e.g., lb, kg).
- TARA: Subtracts the weight of a container or packaging, allowing only the net weight of the contents to be measured.
- HOLD/PRINT: Holds the displayed weight or sends the weight data via the RS232 port.

Figura 3: Detalhado view of the indicator's LCD display and operator keys. The display shows the weight, and the buttons allow for functions like power, unit selection, tare, and data hold/print.
3. Função Tara
To use the Tare function:
- Coloque um recipiente vazio na plataforma.
- Wait for the weight to stabilize.
- Pressione o TARA botão. O visor retornará a "0.00", indicando que o peso do recipiente foi zerado.
- Adicione os itens a serem pesados no recipiente. O visor mostrará apenas o peso líquido dos itens.
4. Computer Interface (RS232)
The scale includes an RS232 port for connecting to a computer or compatible shipping systems. This allows for direct weight data transfer to software like UPS Worldship or FedEx Ship Manager.

Figure 4: The back panel of the indicator unit, highlighting the RS232 serial port for data communication and the power input jack.
Manutenção
1. Limpeza
To maintain accuracy and longevity, keep the scale clean. Wipe the stainless steel platform and indicator unit with a damp cloth. Avoid using abrasive cleaners or excessive water, as this can damage electronic components.
2. Substituição da bateria
If the display becomes dim or the scale does not power on with batteries, replace all four AAA batteries. Ensure correct polarity when inserting new batteries.
3. Calibração
The scale is factory calibrated. If you suspect calibration issues or experience consistent inaccuracies, it is recommended to contact Brecknell customer support or a certified scale technician for recalibration. Do not attempt to self-calibrate unless specifically instructed by official documentation or support.
4. Armazenamento
When not in use for extended periods, store the scale in a dry, stable environment. If using batteries, remove them to prevent leakage and potential damage to the indicator unit.
Solução de problemas
Problemas e soluções comuns
- Scale does not power on:
- Verifique a instalação das baterias e certifique-se de que elas sejam novas.
- Se estiver usando um adaptador CA, certifique-se de que esteja conectado corretamente e que a tomada esteja funcionando.
- Leituras imprecisas:
- Certifique-se de que a balança esteja em uma superfície estável e nivelada.
- Verify that nothing is touching the platform or interfering with its movement.
- Check for debris under the platform.
- Consider recalibration if issues persist (contact support).
- Display shows "OVERLOAD" or "Err":
- Remove any excessive weight from the platform. The scale has a maximum capacity of 400 lb.
- Power cycle the scale (turn off, then on again).
Integrating with UPS Worldship (Advanced Configuration)
Some users have reported challenges with initial setup for UPS Worldship. The following steps, derived from user experience, may assist in configuring the scale for proper communication:
- Configuração da escala:
- Desligue a balança.
- Segure o LIGADO/DESLIGADO/ZERO botão e o UNIDADES button simultaneously to enter setup mode.
- Pressione o TARA button to navigate through parameters (P1 through P20).
- Vá para P4, então pressione o UNIDADES button to change the setting to 7 (NCI protocol).
- Imprensa TARA to save and proceed to P5. Change this to 2 (4800 baud).
- Imprensa TARA to save and proceed to P6. Change this to 2 (7E1).
- Pressione o LIGADO/DESLIGADO/ZERO button to save all settings and exit setup.
- PC Port Settings (Windows):
- Go to Device Manager, then Ports (COM & LPT).
- Double-click on the COM port assigned to your scale (e.g., COM1).
- Go to the "Port Settings" tab and configure as follows:
- Bits por segundo: 4800
- Bits de dados: 7
- Paridade: Até
- Parar bits: 1
- Controle de fluxo: Nenhum
- Click OK and close Device Manager.
- UPS Worldship Configuration:
- Open UPS Worldship.
- Vá para Ferramentas > Preferências do sistema > Hardware.
- Change the "Scale port" to the COM port you configured (e.g., COM1).
- Change the "Scale Type" to NCI 3835.
- Clique Escala de teste. The weight should now report from the scale.
Especificações

Figure 5: Key dimensions and features of the Brecknell SBWLPS400 Portable Shipping Scale, including the stainless steel weighing platform and the high LCD display.
| Recurso | Detalhe |
|---|---|
| Número do modelo | SBWLPS400 |
| Capacidade de peso | 400 libras (181 kg) |
| Precisão de leitura | 0.1 libras (0.005 kg) |
| Dimensões da plataforma (C x L x A) | 15" x 12" x 1" (38.1 cm x 30.5 cm x 2.54 cm) |
| Dimensões gerais do produto | 15.2 x 12.2 x 1.1 polegadas |
| Peso do item | 10.18 libras |
| Material | Alloy Steel, Stainless Steel (Platform) |
| Tipo de exibição | LCD (0.65" high) |
| Fonte de energia | 4 x AAA batteries (included) or optional AC adapter (DC 6V, 500mA) |
| Interface | Porta serial RS232 |
| Usos recomendados | Shipping, general purpose, mailroom, manifest, warehouse |
Garantia e Suporte
Brecknell products are manufactured to high standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Brecknell website.
For technical support, service, or calibration inquiries, please contact Brecknell customer service. You may also find additional resources and frequently asked questions on the official Brecknell support page.
A comprehensive User Manual in PDF format is also available for download from the product's Amazon listing or the manufacturer's website for further detailed information.