Idec BS-001

Manual do Usuário do Bloco de Contato Idec BS-001

Modelo: BS-001

1. Introdução

This manual provides essential information for the safe and effective use of the Idec BS-001 Contact Block. The BS-001 is a normally closed (NC) contact block designed for industrial electrical applications, rated for A 600 and P 600.

Idec BS-001 Contact Block, front-side view

Figura 1: Vista frontal view of the Idec BS-001 Contact Block, showing the main body and screw terminals.

2. Informações de segurança

Always disconnect power before installing, servicing, or removing the contact block. Installation should be performed by qualified personnel in accordance with all local and national electrical codes. Failure to follow these instructions may result in serious injury or property damage.

3. Configuração e instalação

The Idec BS-001 Contact Block is designed for easy integration into control panels and electrical enclosures. It features screw-type connectors for secure wiring.

3.1 Montagem

The contact block typically mounts to a compatible operator or base unit. Ensure the mounting mechanism is secure and the block is firmly seated to prevent vibration-induced disconnections.

3.2 Conexões de Fiação

  1. Identify the Normally Closed (NC) terminals. For the BS-001, it functions as a normally closed contact.
  2. Strip wire insulation to the appropriate length, ensuring no loose strands.
  3. Insert the wire into the screw terminal and tighten the screw firmly to ensure good electrical contact. Do not overtighten.
  4. Verify all connections are secure and correctly wired according to your circuit diagram.
Idec BS-001 Contact Block, top view showing screw terminals

Figura 2: parte superior view of the Idec BS-001 Contact Block, highlighting the screw terminals for wiring connections.

4. Princípios de operação

The Idec BS-001 is a Normally Closed (NC) contact block. This means that in its default, unactuated state, the electrical circuit through the contact block is closed, allowing current to flow. When actuated (e.g., by pressing a pushbutton or activating a switch operator), the contact opens, breaking the circuit.

Idec BS-001 Contact Block, side view showing mounting grooves

Figura 3: Lateral view of the Idec BS-001 Contact Block, illustrating the grooves for secure mounting.

5. Manutenção

The Idec BS-001 Contact Block is designed for long-term reliability with minimal maintenance. However, periodic inspection is recommended to ensure optimal performance and safety.

6. Solução De Problemas

This section provides guidance for common issues that may arise with the Idec BS-001 Contact Block.

ProblemaPossível causaSolução
Contact not making/breaking circuitConexão de fiação solta
Damaged contact block
Incorrect mounting/actuation
Check and tighten all screw terminals.
Inspecione quanto a danos físicos; substitua se necessário.
Ensure the contact block is correctly mounted and the associated operator is functioning properly.
Operação intermitenteFiação solta
Vibração
Contaminação
Proteja todas as conexões.
Ensure the mounting is firm and vibration-free.
Clean the contact block exterior.

7. Especificações

AtributoValor
MarcaIdec
Número do modeloBS-001
Número da peça (PN)BS-001
Tipo de contatoNormalmente fechado (NC)
Classificação elétricaA 600, P 600
Tipo de conectorParafuso
FabricanteIdec
Data da primeira disponibilidade26 de novembro de 2015

8. Garantia e Suporte

For warranty information or technical support regarding your Idec BS-001 Contact Block, please refer to the official Idec website or contact your authorized Idec distributor. Specific warranty terms may vary by region and purchase agreement.

Documentos relacionados - BS-001

Préview Interruptores e luzes piloto da série YW da IDEC - Catálogo de produtos abrangente
Explore a série IDEC YW de interruptores e luzes piloto de Ø22 e Ø30, incluindo interruptores de parada de emergência, botões de pressão, interruptores seletores, interruptores seletores de chave e luzes piloto. View especificações, números de peças, dimensões e acessórios.
Préview IDEC XW7E-BS312PK Collector User Manual and Specifications
Comprehensive user manual and technical specifications for the IDEC XW7E-BS312PK Collector, including safety precautions, electrical ratings, dimensions, mounting, wiring, maintenance, and troubleshooting.
Préview Blocos de terminais da série IDEC BNH/BN: especificações, dimensões e acessórios
Guia completo dos blocos de terminais das séries BNH/BN da IDEC, incluindo características principais, especificações detalhadas, dimensões, acessórios e instruções de instalação. Abrange as séries BNH, BN e BN Power Block.
Préview Chaves de habilitação IDEC: Série HE2B, HE3B, HE5B, HE6B, HE2G, HE1G-L - Catálogo de produtos e especificações
Guia completo para as chaves habilitadoras de 3 posições da série HE da IDEC, incluindo os modelos HE2B, HE3B, HE5B, HE6B, HE2G e HE1G-L. Apresenta especificações detalhadas, precauções de segurança, instruções de operação e diagramas de fiação para aplicações industriais.
Préview Notícias técnicas da IDEC: Problemas de software com o organizador de automação SW1A WindO/I-NV4
Este documento detalha cinco problemas identificados no software SW1A Automation Organizer, especificamente na versão WindO/I-NV4. Ele fornece informações sobre os fenômenos, produtos afetados e soluções recomendadas para cada problema.
Préview Guia de Programação do Controlador de Segurança IDEC FS1B
Esta nota de aplicação fornece um guia passo a passo para programar a lógica, o temporizador e as entradas de segurança do controlador de segurança IDEC FS1B. Ela detalha o processo de configuração das chaves DIP, seleção dos valores de programação da lógica e do temporizador e configuração das entradas de segurança, ilustrado com descrições da interface do dispositivo.