Legrand 138074

Legrand 138074 Manual Call Point Instruction Manual

Guia completo para instalação, operação e manutenção.

1. Produto acabadoview

The Legrand 138074 is a manual call point designed for fire alarm systems. It features a white housing, two contacts, and an integrated LED indicator. This device allows for manual activation of a fire alarm in emergency situations, providing a clear visual and tactile indication of activation.

Legrand 138074 Manual Call Point front view

Figura 1: Frente view of the Legrand 138074 Manual Call Point.

2. Informações de segurança

Leia e compreenda todas as instruções de segurança antes de instalar ou operar este dispositivo. O não cumprimento destas instruções pode resultar em danos materiais, ferimentos ou morte.

  • Instalação profissional: Installation must be performed by qualified personnel in accordance with all local and national electrical codes and fire safety regulations.
  • Desconexão de energia: Always disconnect power to the circuit before performing any installation, maintenance, or troubleshooting.
  • Volumetage Verifique: Verifique se o volume da fonte de alimentaçãotage corresponde às especificações do dispositivo.
  • Condições ambientais: Do not install in areas with excessive moisture, extreme temperatures, or corrosive environments.
  • Integridade dos componentes: Não utilize o dispositivo se alguma parte estiver danificada.

3. Conteúdo da embalagem

Ao abrir a embalagem, verifique se todos os componentes estão presentes e sem danos:

  • Legrand 138074 Manual Call Point (1 unit)
  • Parafusos de montagem (quantidade conforme fornecido)
  • Manual de Instruções (este documento)

4. Configuração e instalação

The Legrand 138074 Manual Call Point is designed for surface or flush mounting. Ensure the chosen location complies with local fire safety regulations regarding accessibility and visibility.

4.1. Montagem

  1. Prepare a superfície de montagem: Ensure the surface is clean, dry, and flat.
  2. Marque os pontos de perfuração: Use the call point's base as a template to mark the positions for mounting screws.
  3. Furos de perfuração: Drill pilot holes appropriate for the mounting screws.
  4. Proteja a Base: Attach the call point's base securely to the wall using the provided screws.

4.2. Fiação

Refer to the wiring diagram below and your fire alarm control panel's documentation for correct connection. This device features 2 contacts and an LED indicator.

  • Connect the alarm circuit wires to the designated terminals (typically NO/NC contacts).
  • Connect the LED indicator wires to the appropriate power source and signaling circuit as per your system's requirements.
  • Certifique-se de que todas as conexões estejam seguras e devidamente isoladas.
Legrand 138074 Manual Call Point wiring diagram

Figura 2: interno view and wiring terminals of the Legrand 138074 Manual Call Point.

4.3. Montagem Final

  1. Carefully place the front cover onto the mounted base, ensuring all wires are tucked away and not pinched.
  2. Secure the cover with any retaining screws or clips provided.
  3. Restore power to the circuit and test the device according to your fire alarm system's testing procedures.

5. Instruções de operação

In the event of a fire or other emergency requiring immediate alarm activation:

  1. Locate the Call Point: Identify the nearest Legrand 138074 Manual Call Point.
  2. Ative o alarme: Firmly press the designated activation area on the call point. This action will typically break a frangible element or activate a switch.
  3. Verify Activation: The integrated LED indicator should illuminate, confirming that the call point has been activated and the signal sent to the fire alarm control panel.
  4. Evacuar: Follow your building's emergency evacuation procedures.

Note: Resetting the call point typically requires a special key or tool to return the activation mechanism to its original state after an alarm. Consult your fire alarm system administrator for reset procedures.

6. Manutenção

Regular maintenance ensures the reliable operation of your manual call point.

  • Inspeção visual: Periodically inspect the call point for any signs of physical damage, tampering, or obstruction. Ensure the LED is functional during system tests.
  • Limpeza: Clean the exterior of the call point with a soft, damp pano. Não use produtos de limpeza abrasivos ou solventes.
  • Teste Funcional: Conduct regular functional tests as required by local fire safety regulations and your fire alarm system's maintenance schedule. This should be performed by qualified personnel.
  • Substituição de componentes: If the frangible element is broken or the device is damaged, it must be replaced by a qualified technician.

7. Solução De Problemas

If you encounter issues with your Legrand 138074 Manual Call Point, refer to the table below. For problems not listed, contact qualified service personnel.

Problema Possível causa Solução
LED not illuminating upon activation Incorrect wiring for LED; LED faulty; No power to LED circuit. Check LED wiring connections; Test LED circuit for power; Replace call point if LED is faulty.
Alarm not activating when call point is pressed Incorrect wiring for contacts; Contacts faulty; Issue with fire alarm control panel. Verify contact wiring; Test continuity of contacts; Consult fire alarm control panel manual or technician.
Call point appears damaged Physical impact; Vandalism. Replace the damaged call point immediately.

8. Especificações

Recurso Detalhe
Fabricante Legrand
Número do modelo 138074
Tipo de produto Botoneiras
Cor Branco
Contatos 2 contatos
Indicador LED integrado
Peso do produto 0.05 g
ASIN B018PB4SP8
Primeira data disponível 19 de maio de 2016

9. Informações de garantia

Legrand products are manufactured to high standards and are typically covered by a limited warranty against defects in materials and workmanship. The specific warranty period and terms may vary by region and product type. Please retain your proof of purchase. For detailed warranty information, refer to the official Legrand website or contact Legrand customer support in your region.

10. Suporte e Contato

For technical assistance, product inquiries, or to report issues, please contact Legrand customer support. You can find contact information, including phone numbers and online support portals, on the official Legrand website:

Www.legrand.com

Ao entrar em contato com o suporte, tenha em mãos o número do modelo do seu produto (138074) e quaisquer detalhes relevantes da compra.