Extech EX355

Extech EX355 True RMS Multimeter with Temperature Measurement Instruction Manual

Modelo: EX355

1. Introdução

This manual provides detailed instructions for the safe and effective operation of the Extech EX355 True RMS Multimeter. The EX355 is a professional digital multimeter designed for a wide range of electrical measurements, including AC/DC voltage, current, resistance, capacitance, frequency, duty cycle, and temperature. It features True RMS for accurate readings of non-sinusoidal waveforms, Non-Contact Voltage (NCV) detection for enhanced safety, Low Impedance (LoZ) mode to prevent ghost voltage readings, and a Low Pass Filter (LPF) for noise reduction in electrical environments.

Please read this manual thoroughly before using the device to ensure proper function and to prevent potential hazards.

2. Informações de segurança

Always adhere to the following safety precautions to avoid personal injury or damage to the multimeter:

3. Produto acabadoview

The Extech EX355 is a versatile True RMS Multimeter equipped with several advanced features for accurate and safe electrical testing.

Principais características:

Extech EX355 True RMS Multimeter

Figure 1: The Extech EX355 True RMS Multimeter. This image shows the front view of the multimeter, highlighting its display, rotary dial, function buttons, and input jacks.

4. Configuração

4.1 Instalação da bateria

The Extech EX355 requires two (2) AA batteries for operation. These are typically included with the device.

  1. Certifique-se de que o multímetro esteja desligado.
  2. Localize a tampa do compartimento da bateria na parte traseira da unidade.
  3. Desaperte o(s) parafuso(s) de fixação e remova cuidadosamente a tampa.
  4. Insira duas pilhas AA, observando a polaridade correta (+ e -) conforme indicado dentro do compartimento.
  5. Recoloque a tampa do compartimento da bateria e fixe-a com o(s) parafuso(s).

Observação: Replace batteries immediately when the low battery indicator appears on the display to maintain measurement accuracy.

4.2 Conectando os Cabos de Teste

Conecte sempre os cabos de teste corretamente para a função de medição desejada.

5. Instruções de operação

This section details how to perform various measurements using the Extech EX355 multimeter.

5.1 Vol AC/DCtage Medição

  1. Coloque o seletor rotativo na posição V~ (AC Voltage) ou V- (DC Vol.tage) posição.
  2. Conecte o cabo de teste vermelho ao CAPA VΩHz Jack e o teste preto levam ao COM Jack.
  3. Toque as pontas de prova nos pontos do circuito onde há tensão.tage deve ser medido.
  4. Leia o vol.tage valor no display.

5.2 Medição de corrente CA/CC

Cuidado: Nunca ligue o multímetro em paralelo com um circuito de voltagem.tagAo medir a corrente, utilize uma fonte de alimentação. Sempre conecte em série com a carga.

  1. Set the rotary dial to the appropriate A~ (Corrente CA) ou A- (DC Current) range (e.g., 10A or mAµA).
  2. Conecte o cabo de teste vermelho ao 10A or mAµA Jack e o teste preto levam ao COM Jack.
  3. Open the circuit where current is to be measured and connect the test probes in series.
  4. Leia o valor atual no visor.

5.3 Medição de Resistência

Aviso: Certifique-se de que o circuito esteja desenergizado antes de medir a resistência.

  1. Coloque o seletor rotativo na posição Ω (Posição de resistência).
  2. Conecte o cabo de teste vermelho ao CAPA VΩHz Jack e o teste preto levam ao COM Jack.
  3. Touch the test probes across the component or circuit segment to be measured.
  4. Leia o valor da resistência no display.

5.4 Medição de Capacitância

Aviso: Discharge capacitors before measuring to prevent damage to the meter.

  1. Coloque o seletor rotativo na posição CAP (Posição de capacitância).
  2. Conecte o cabo de teste vermelho ao CAPA VΩHz Jack e o teste preto levam ao COM Jack.
  3. Encoste as pontas de prova nos terminais do capacitor.
  4. Leia o valor da capacitância no display.

5.5 Medição de Frequência e Ciclo de Trabalho

  1. Coloque o seletor rotativo na posição Hz /% Posição (Frequência/Ciclo de Trabalho).
  2. Conecte o cabo de teste vermelho ao CAPA VΩHz Jack e o teste preto levam ao COM Jack.
  3. Touch the test probes to the signal source.
  4. Pressione o Hz /% button to toggle between frequency and duty cycle readings.

5.6 Medição de Temperatura

The EX355 includes a general purpose bead wire temperature probe.

  1. Coloque o seletor rotativo na posição Temperatura (Temperatura) posição.
  2. Insert the temperature probe into the CAPA VΩHz (positivo) e COM (negative) jacks, observing polarity.
  3. Place the tip of the temperature probe on or in the object to be measured.
  4. Read the temperature value on the display. The unit can display in Celsius or Fahrenheit.
Man using Extech EX355 Multimeter for temperature measurement in an air vent

Figure 2: Using the Extech EX355 to measure temperature in an HVAC vent. The image shows a person holding the multimeter and inserting the temperature probe into an air conditioning vent.

5.7 Volume sem contatotage (NCV) Detecção

NCV mode allows for quick detection of AC voltage sem contato direto, aumentando a segurança.

  1. Coloque o seletor rotativo na posição VNC posição.
  2. Move the top of the multimeter near a conductor or outlet.
  3. The NCV indicator light will illuminate and an audible beep will sound if AC voltage is detected. The intensity of the beep and light may increase with stronger fields.

5.8 Low Impedance (LoZ) Mode

LoZ mode helps eliminate false readings caused by ghost voltage.

  1. Coloque o seletor rotativo na posição LoZ V posição.
  2. Connect the test leads as for standard voltage medição.
  3. The meter will present a low impedance load to the circuit, dissipating ghost voltages and providing a more accurate reading of actual voltage.

5.9 Filtro Passa-Baixa (LPF)

The LPF function is used to filter out high-frequency noise, providing stable readings in variable frequency drive (VFD) applications or other noisy electrical environments.

  1. Set the rotary dial to an AC Voltage (V~) or AC Current (A~) faixa.
  2. Pressione o LPF button to activate the low pass filter. The LPF icon will appear on the display.
  3. Perform your measurement as usual. The meter will now display readings with high-frequency noise attenuated.
  4. Pressione o LPF button again to deactivate the filter.
Extech EX355 Multimeter connected to an electrical control panel

Figure 3: The Extech EX355 Multimeter in use, connected to an electrical control panel. This image demonstrates the multimeter's application in industrial or commercial electrical diagnostics.

Extech EX355 Multimeter connected to a fuse box

Figure 4: The Extech EX355 Multimeter connected to a fuse box. This image illustrates the multimeter being used for testing within a residential or commercial electrical distribution system.

5.10 Data Hold, Min/Max, Relative Mode

5.11 Continuity and Diode Test

Aviso: Ensure the circuit is de-energized before performing continuity or diode tests.

6. Manutenção

6.1 Substituição da bateria

Refer to section 4.1 for detailed instructions on replacing the two AA batteries. Always use fresh, high-quality AA batteries.

6.2 Substituição de fusíveis

If the current measurement functions cease to work, the fuse may need replacement. This procedure should only be performed by qualified personnel.

  1. Ensure the multimeter is powered off and all test leads are disconnected.
  2. Remova a tampa do compartimento das pilhas e as pilhas.
  3. Unscrew the case screws and carefully separate the two halves of the meter casing.
  4. Locate the blown fuse(s). The EX355 typically uses two fuses: a 0.5A/600V fast-blow fuse for the mA/µA input and a 10A/600V fast-blow fuse for the 10A input.
  5. Replace the fuse(s) with fuses of the exact same type and rating. Never use a fuse with a different rating.
  6. Carefully reassemble the meter casing, ensuring all screws are tightened. Reinstall batteries and the battery cover.

6.3 Limpeza e Armazenamento

7. Solução De Problemas

ProblemaPossível causaSolução
Sem imagem ou imagem fracaBaterias descarregadas ou fracasSubstitua as baterias (consulte a Seção 4.1).
Leituras incorretasIncorrect function/range selected; Damaged test leads; External interference; Blown fuse (for current)Verify function/range; Inspect/replace test leads; Move away from strong electromagnetic fields; Check/replace fuses (refer to Section 6.2).
Sem sinal sonoro de continuidadeOpen circuit; High resistance; Incorrect modeEnsure circuit is closed; Check for high resistance; Verify continuity mode is selected.
A medição de corrente não está funcionando.Blown fuse; Incorrect lead connectionCheck and replace appropriate fuse (refer to Section 6.2); Ensure leads are in the correct current jacks.
NCV não detecta volumetageSem vol CAtage present; Weak field; Incorrect modeVerifique o volume da CAtage with direct contact method; Ensure NCV mode is selected; Move closer to the conductor.

8. Especificações

The following table outlines the key specifications for the Extech EX355 True RMS Multimeter:

ParâmetroValor
Número do modeloEX355
Funções de MediçãoAC / DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Temperature, Diode, Continuity
RMS verdadeiroSim
Vol sem contatotage (NCV)Sim
Low Impedance (LoZ)Sim
Filtro passa-baixo (LPF)Sim
Vol operacional máximotage600 Volts
Precisão de medição+/-0.5% (typical, varies by function/range)
Mostrar4000 Count LCD
Fonte de energia2 pilhas AA (incluídas)
Dimensões (C x L x A)8.1 x 4.8 x 17 cm (3.2 x 1.9 x 6.7 polegadas)
Peso do item372 g (0.82 lbs)
Materialabdômen
CertificaçãoIEC 61010-1, CE, CAT III 600V
Componentes incluídosTest leads, two AA batteries, general purpose bead wire temperature probe
Extech EX355 Multimeter with dimensions overlay

Figure 5: Extech EX355 Multimeter with approximate dimensions shown in inches and centimeters. This image provides a visual reference for the physical size of the device.

9. Informações de garantia

Extech provides a warranty for its products. Specific warranty terms and conditions, including duration and coverage, may vary by region and product. For detailed warranty information, please refer to the warranty card included with your product or visit the official Extech webGuarde o comprovante de compra como prova para eventuais solicitações de garantia.

10. Suporte ao cliente

For technical assistance, troubleshooting, or service inquiries regarding your Extech EX355 Multimeter, please contact Extech customer support. You can typically find contact information, including phone numbers and email addresses, on the official Extech website ou na documentação fornecida com o seu produto.

Recursos on-line: Visit the official Extech website for FAQs, product downloads, and additional support resources.

Documentos relacionados - EX355

Préview Multímetros Extech: Guia completo de multímetros digitais e testadores de isolamento
Explore a linha de multímetros digitais (DMMs) e testadores de isolamento da Extech, incluindo as séries EX300, EX350, EX360, EX400, EX500, MM750W, MG320, MG325, DM220, MN35/36 e 381676A. Os recursos incluem True RMS, NCV, LPF, LoZ, medição de temperatura e registro de dados sem fio.
Préview EXTECH MG320 Insulation Tester + DMM User Manual
User manual for the EXTECH MG320 True RMS Insulation Resistance CAT IV 600V DMM, covering features, safety, operating instructions, maintenance, and specifications.
Préview Guia do Usuário do Datalogger Analisador de Potência Extech 380801 e 380803
Guia do usuário para os analisadores de energia Extech 380801 e 380803 (datalogger). Detalhes sobre recursos, especificações, operação básica, descrição do medidor e informações sobre a garantia para análise de energia elétrica.
Préview Extech DV30 AC VoltagManual do usuário do detector e
Manual do usuário para o Extech DV30 AC Vol.tage Detector, detalhando precauções de segurança, operação, especificações, substituição da bateria, descarte, garantia e informações de contato.
Préview Multímetro True RMS Extech EX470A com Termômetro IR - Manual do Usuário
Manual do usuário completo para o multímetro e termômetro infravermelho Extech EX470A True RMS com seleção automática de faixa, abrangendo informações de segurança, operação, especificações, manutenção e garantia.
Préview Guia do Usuário do Multímetro de Bolso Extech DM100
Manual do usuário do multímetro de bolso Extech DM100 com 4000 contagens e seleção automática de faixa, abordando segurança, especificações, operação, recursos e manutenção.