1. Terminadoview
The Fluke 15B+ Digital Multimeter is a rugged, reliable, and accurate tool designed for various electrical applications. It offers essential measurement capabilities in a user-friendly design, suitable for both professional and serious DIY users.

Imagem: Frente view of the Fluke 15B+ Digital Multimeter, showing the display, rotary dial, and input jacks.
Principais características:
- Classificação de segurança CAT III 600V: Ensures safety for electrical systems in residential and commercial settings.
- AC / DC Voltage Measurement up to 1000V: Mede AC e DC voltage for a wide range of applications.
- AC/DC Current Measurement up to 10A: Accurately measures AC and DC current for diagnosing electrical issues.
- Múltiplas funções de medição: Inclui voltage, Resistance, Continuity, Diode, and Capacitance.
- Input Terminal for AC/DC Current Measurements: Dedicated input for current measurements up to 10A.
2. Informações de segurança
Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the meter or equipment under test.
- Leia as instruções: Read and understand all instructions and safety information before use.
- Uso adequado: Use the multimeter only as specified in this manual; otherwise, the protection provided by the multimeter might be impaired.
- Vol avaliadotage: Não aplique mais do que o volume nominaltage, as marked on the multimeter, between the terminals or between any terminal and earth ground.
- Inspect Leads: Inspect test leads for damaged insulation or exposed metal. Replace damaged leads.
- Avoid Live Circuits: Do not use the multimeter on live circuits with exposed conductors or bus bars.
- Equipamento de Proteção Individual (EPI): Always wear appropriate personal protective equipment, such as safety glasses and insulated gloves, when working with electrical systems.
- CAT III 600V: This meter is rated for CAT III 600V. Do not use it in environments exceeding this rating.
3. O que está na caixa
Your Fluke 15B+ Digital Multimeter package includes the following items:
- Fluke 15B+ Digital Multimeter
- Cabos de teste TL75
- 2 pilhas AA (pré-instaladas ou incluídas separadamente)

Image: The Fluke 15B+ Digital Multimeter shown alongside its red and black TL75 test leads and protective caps.
4. Configuração
4.1 Instalação da bateria
The Fluke 15B+ requires two AA batteries for operation. These are typically included with your purchase.
- Certifique-se de que o multímetro esteja desligado.
- Localize a tampa do compartimento da bateria na parte traseira do multímetro.
- Use uma chave de fenda para soltar o(s) parafuso(s) que prendem a tampa.
- Remove the cover and insert the two AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Recoloque a tampa do compartimento da bateria e aperte os parafusos.
4.2 Conectando os Cabos de Teste
A conexão correta dos cabos de teste é crucial para medições precisas e seguras.
- Insira o preto teste leva ao COM Conector de entrada (comum).
- Para a maioria dos volumestage, resistance, continuity, diode, and capacitance measurements, insert the vermelho teste leva ao CAPA VΩHz tomada de entrada.
- For current measurements (mA/A), insert the vermelho test lead into the appropriate current input jack (e.g., mA / A or 10A FUSED), depending on the expected current level. Refer to the multimeter's faceplate for specific jack labels.
5. Instruções de operação
5.1 Operação Geral
- Ligar/desligar: Rotate the central dial from the OFF position to any desired measurement function to turn the meter on. Rotate back to OFF to power off.
- Seleção de função: Use the central rotary dial to select the desired measurement function (e.g., V~ for AC Voltage, V- para DC Voltage, Ω para Resistência).
- Botão de alcance: Pressione o GAMA button to manually select a measurement range if auto-ranging is not desired. Press again to cycle through ranges or hold to return to auto-ranging.
- Pressionar botão: Pressione o SEGURAR Pressione o botão para congelar a leitura atual no visor. Pressione novamente para liberar.
- Botão de luz de fundo: Press the backlight button (sun icon) to illuminate the display in low-light conditions.

Image: A gloved hand holding the Fluke 15B+ Digital Multimeter, demonstrating its ergonomic design.
5.2 Funções de Medição
5.2.1 Vol AC/DCtage Medição
- Gire o botão rotativo para V~ (AC Voltage) ou V- (DC Vol.tage)
- Connect the black test lead to the COM terminal and the red test lead to the VΩHzCAP terminal.
- Carefully touch the test probes to the points where voltage is to be measured (in parallel with the circuit).
- Leia o vol.tage valor no display.
5.2.2 Medição de corrente CA/CC
Cuidado: Always ensure the circuit is de-energized before connecting the multimeter in series for current measurements. Incorrect connection can blow the fuse or damage the meter.
- Gire o botão rotativo para A~ (Corrente CA) ou A- (DC Current).
- Conecte a ponta de prova preta ao terminal COM.
- Para correntes de até 400 mA, conecte o fio de teste vermelho ao mA / A terminal. For currents up to 10A, connect the red test lead to the 10A FUSED terminal.
- Abra o circuito onde a corrente deve ser medida e conecte o multímetro em série.
- Religue o circuito e leia o valor da corrente no visor.

Image: The Fluke 15B+ Digital Multimeter connected to an electrical panel, displaying a voltage leitura.
5.2.3 Medição de Resistência
- Gire o botão rotativo para Ω (Resistance).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Ensure the component or circuit under test is de-energized.
- Touch the test probes across the component or circuit.
- Leia o valor da resistência no display.
5.2.4 Teste de Continuidade
- Gire o botão rotativo para o Continuidade symbol (looks like a sound wave).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Certifique-se de que o circuito em teste esteja desenergizado.
- Touch the test probes across the points to be tested.
- The meter will beep if a continuous path (low resistance) is detected. The display will show the resistance value.
5.2.5 Teste de Diodo
- Gire o botão rotativo para o Diodo symbol (looks like an arrow with a bar).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Certifique-se de que o diodo esteja desconectado do circuito.
- Touch the red probe to the anode and the black probe to the cathode. A forward voltage drop (e.g., 0.5V to 0.8V for silicon diodes) should be displayed.
- Reverse the probes. The display should show OL (Open Loop) for a good diode.
5.2.6 Medição de Capacitância
- Gire o botão rotativo para o Capacitância symbol (looks like two parallel lines).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Certifique-se de que o capacitor esteja completamente descarregado antes de testá-lo.
- Encoste as pontas de prova nos terminais do capacitor.
- Leia o valor da capacitância no display.

Image: A technician wearing safety gear, using the Fluke 15B+ Digital Multimeter to take a reading inside an electrical panel.
6. Manutenção
6.1 Limpeza
Para limpar o multímetro, limpe a carcaça com um pano úmido.amp Limpe com pano e detergente neutro. Não utilize abrasivos ou solventes. Certifique-se de que o medidor esteja completamente seco antes de usar.
6.2 Substituição da bateria
Replace the batteries when the low battery indicator appears on the display. Refer to Section 4.1 for battery installation instructions.
6.3 Substituição de fusíveis
If the current measurement function stops working, the fuse may need replacement. Always replace with a fuse of the specified type and rating to maintain safety and performance.
- Certifique-se de que o multímetro esteja desligado e os cabos de teste desconectados.
- Abra a tampa do compartimento da bateria conforme descrito na Seção 4.1.
- Remova cuidadosamente o fusível antigo.
- Install a new fuse of the correct type and rating (refer to the specifications section or the meter's internal markings).
- Recoloque a tampa do compartimento da bateria e aperte os parafusos.
7. Solução De Problemas
- Nenhuma exibição: Verifique a instalação e a carga da bateria. Substitua as baterias, se necessário.
- Leituras incorretas: Ensure test leads are correctly connected to the appropriate input jacks for the selected function. Verify the rotary dial is set to the correct measurement function. Check for damaged test leads.
- Medição atual não está funcionando: Check the fuse. Replace if blown (refer to Section 6.3). Ensure the red test lead is in the correct current input jack.
- Exibição "OL": This typically means "Overload" or "Open Loop." For resistance, it indicates an open circuit. For diode test, it indicates a reverse-biased good diode. For voltage/current, it means the measured value exceeds the selected range (if not in auto-range) or the meter's maximum capability.
8. Especificações
| Especificação | Valor |
|---|---|
| Número do modelo | FLUKE-15B+ |
| Classificação de segurança | CATIII 600V |
| AC / DC Voltage | Até 1000V |
| Corrente AC / DC | Até 10A |
| Resistência | Sim |
| Continuidade | Sim |
| Teste de diodo | Sim |
| Capacitância | Sim |
| Fonte de energia | 2 pilhas AA (incluídas) |
| Dimensões do produto | 8.46 x 2.76 x 5.91 polegadas |
| Peso do item | 1.01 libras (460 gramas) |
| Fabricante | Corporação Fluke |
9. Garantia e Suporte
The Fluke 15B+ Digital Multimeter is manufactured by Fluke Corporation. For detailed warranty information, technical support, or service, please refer to the official Fluke website or contact their customer service directly. Always ensure you purchase from authorized distributors to guarantee product authenticity and valid warranty coverage.
Para obter recursos adicionais e informações sobre o produto, visite o Loja Fluke na Amazon.