This manual provides essential information for the proper installation, operation, and maintenance of your Buderus Logafix Universal Bathroom Radiator Valve Kit, model 7738324180. Please read these instructions carefully before installation and retain them for future reference. This kit includes a chrome universal valve and a T-head valve set, designed for standard 2-tube heating systems.
Características do produto
- Aplicação universal: Designed for versatile use, suitable for both angle and straight-through connections.
- Standard 50 mm Connection: Ensures compatibility with common radiator setups.
- 2-Tube System Compatibility: Optimized for standard 2-tube heating system applications.
- Reversible Thermostatic Valve: The thermostatic valve can be adjusted for right or left-hand installation, offering flexible setup options.
- Acabamento cromado: Durável e esteticamente agradávelasing chrome plating.

Image 1: Buderus Logafix Universal Radiator Valve Kit. This image displays the chrome-finished valve unit with its two connection points and the thermostatic control knob.
Configuração e instalação
Installation of this radiator valve should be performed by a qualified professional to ensure correct function and prevent leaks. Incorrect installation can lead to system damage or personal injury.
- Preparação do sistema: Ensure the heating system is depressurized and drained before beginning installation.
- Orientação da válvula: Determine whether an angle or straight-through connection is required for your radiator. The universal design accommodates both.
- Thermostatic Head Adjustment: The thermostatic valve head can be rotated to either the right or left side for optimal access and aesthetic integration. Adjust this before final tightening.
- Conexão: Connect the valve to the radiator and the heating pipes using appropriate sealing materials. The valve features a standard 50 mm connection.
- Aperto: Secure all connections firmly but avoid over-tightening, which can damage threads or seals.
- Recarga e teste do sistema: After installation, refill the heating system, bleed air from the radiator, and check all connections for leaks.
Refer to your radiator and heating system manuals for specific connection requirements and safety guidelines.
Instruções de operação
The Buderus Logafix Universal Radiator Valve allows you to control the heat output of your radiator, contributing to energy efficiency and comfort.
- Controle de temperatura: Rotate the thermostatic head to adjust the desired room temperature. Higher numbers or symbols typically indicate warmer settings.
- Proteção contra geada: Most thermostatic valves include a frost protection setting (often marked with an asterisk or snowflake symbol). This setting maintains a minimum temperature to prevent pipes from freezing.
- Full Open/Closed: The valve can be fully opened for maximum heat or fully closed to shut off heat to the radiator.
Allow time for the room temperature to stabilize after adjusting the valve setting.
Manutenção
Regular maintenance ensures the longevity and efficient operation of your radiator valve.
- Limpeza: Clean the chrome surface with a soft, damp pano. Evite produtos de limpeza abrasivos ou solventes, que podem danificar o acabamento.
- Valve Movement: Periodically (e.g., once a year before the heating season), turn the thermostatic head through its full range of motion several times. This helps prevent the valve pin from sticking, especially if the valve has been in one position for an extended period.
- Inspeção de vazamento: Regularly check connections for any signs of water leaks. Address any leaks immediately by tightening connections or replacing seals if necessary.
Solução de problemas
| Problema | Possível causa | Solução |
|---|---|---|
| O radiador não está aquecendo. | Valve is closed or stuck. Air in the radiator. | Turn the thermostatic head to a higher setting. Rotate the head through its full range of motion. Bleed the radiator. |
| Radiator is too hot, even on low setting. | Valve not closing completely. | Ensure the thermostatic head is correctly seated. Rotate the head through its full range of motion to free the valve pin. If problem persists, professional inspection may be needed. |
| Water leak at connections. | Loose connection or faulty seal. | Depressurize the system. Carefully tighten the connection. If leak persists, replace the seal or contact a professional. |
Especificações
| Atributo | Detalhe |
|---|---|
| Fabricante | Buderus |
| Número do modelo | 7738324180 |
| Dimensões do produto | 22.2 x 14 x 5.8 cm |
| Peso do item | 580 gramas |
| Tipo de conexão | Universal (Angle or Straight-through) |
| Tamanho da conexão | Padrão 50 mm |
| Compatibilidade do sistema | Standard 2-tube heating systems |
| Terminar | Cromo |
| Pilhas necessárias | Não |
Garantia e Suporte
Information regarding specific warranty terms and conditions for the Buderus Logafix Universal Bathroom Radiator Valve Kit is not available in the provided product data. For warranty claims or technical support, please contact Buderus directly or refer to the documentation provided at the time of purchase.
Fabricante: Buderus
Número do modelo: 7738324180