Ebara 1100090000

Manual do usuário da bomba autoescorvante EBARA AGA 0.75 m

Modelo: 1100090000

1. Produto acabadoview

The EBARA AGA 0.75 M is a robust single-phase self-priming electric pump constructed from cast iron, designed for efficient clean water transfer. Its applications include domestic water pressure boosting, small-scale garden irrigation, vehicle washing, and general water movement tasks.

EBARA AGA 0.75 M Single-Phase Self-Priming Cast Iron Pump

This image shows the EBARA AGA 0.75 M self-priming pump, featuring a blue cast iron body and an integrated electric motor with a black terminal box on top. The pump has visible inlet and outlet connections.

2. Configuração e instalação

Proper installation is crucial for the pump's performance and longevity. Follow these general guidelines:

  1. Colocação: Install the pump in a dry, well-ventilated area, protected from frost and direct sunlight. Ensure a stable, level surface to minimize vibration.
  2. Conexões de tubulação: Connect the suction pipe to the pump's G1 suction port and the delivery pipe to the G1 delivery port. Ensure all connections are airtight to prevent air ingress, which can affect priming. Use appropriate sealants and fittings.
  3. Conexão elétrica: The pump operates on 230 V ± 10% 50 Hz single-phase power. Connect the pump to a suitable electrical supply according to local regulations. Ensure the circuit is protected by a permanent capacitor and an automatic reset thermal-amperometric protection device.
  4. Preparação: As a self-priming pump, it can draw water from a certain depth (up to 8m). Before initial startup, fill the pump body completely with clean water through the priming port until it overflows. This ensures the pump can establish suction.

3. Instruções de operação

Once installed and primed, the pump is ready for operation:

  • Inicialização inicial: After priming, switch on the power supply. The pump should start drawing water and build pressure.
  • Monitoramento: Observe the pump during operation. Listen for unusual noises and check for leaks. Ensure consistent water flow and pressure.
  • Operação contínua: The pump is designed for continuous duty within its specified operating limits. Avoid running the pump dry, as this can cause damage to the mechanical seal.
  • Desligar: Para parar a bomba, basta desligar a fonte de alimentação.

4. Manutenção

Regular maintenance helps ensure the longevity and efficient operation of your pump:

  • Inspeção regular: Periodically check all connections for leaks and ensure the pump is securely mounted. Inspect the power cable for any damage.
  • Limpeza: Keep the pump exterior clean and free from debris. Ensure the motor's ventilation fins are not obstructed to prevent overheating.
  • Preparação para o inverno (se aplicável): In areas prone to freezing temperatures, drain the pump completely to prevent damage from ice expansion. Disconnect pipes and open drain plugs. Store the pump in a frost-free environment if possible.
  • Selo mecânico: The mechanical seal is a wear part. If persistent leaks occur from the shaft area, the seal may need replacement by a qualified technician.

5. Solução De Problemas

Esta seção aborda problemas comuns que você pode encontrar:

ProblemaPossível causaSolução
A bomba não iniciaNo power supply; Motor overload protection tripped; Seized impellerCheck power connection and circuit breaker; Allow motor to cool and reset protection; Contact qualified technician.
A bomba funciona, mas não há fluxo de água.Pump not primed; Air leak in suction line; Suction lift too high; Clogged suction filterRe-prime the pump; Check all suction connections for leaks; Ensure suction depth is within 8m limit; Clean suction filter.
Low pressure or reduced flowPartial air leak; Partially clogged impeller/pipes; Worn impeller or mechanical sealCheck suction line for small leaks; Inspect and clean impeller/pipes; Contact qualified technician for inspection.
Ruído excessivo ou vibraçãoCavitation (air in water); Loose mounting; Bearing wearEnsure proper priming and no air leaks; Securely fasten pump; Contact qualified technician.

6. Especificações

RecursoDetalhe
FabricanteEbara
Número do modelo1100090000
MaterialFerro fundido
Fonte de energiaElétrico com fio
Volumetage230 Volts (CA)
Pressão máxima de operação6 barras
Temperatura Líquida Máxima45 °C
Profundidade Máxima de Sucção8m
Conexão de sucçãoG1
Delivery ConnectionG1
Eficiência do motorIE2 and IE3 (from 0.75 kW)
Classe de isolamentoF
Grau de ProteçãoIP44
Dimensões da embalagem40.5 x 18.5 x 18 cm
Peso do item12.5 quilogramas
Pilhas incluídasNão
Pilhas necessáriasNão
Disponibilidade de peças de reposiçãoInformação indisponível

7. Garantia e Suporte

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your authorized Ebara dealer. Information regarding spare parts availability is currently not provided in the product specifications.

Documentos relacionados - 1100090000

Préview Bombas de superfície EBARA JE(S)(X), AG(..) - Manual de Operação e Manutenção
Manual completo de operação e manutenção para bombas de superfície das séries EBARA JE(S)(X), AG(..). Inclui especificações técnicas, diretrizes de instalação, instruções de uso e precauções de segurança.
Préview EP BASIC 1-2 Electronic Control Panel for Single or Three-Phase Pumps
The EP BASIC 1-2 is an electronic control panel designed for managing one or two single-phase or three-phase pumps. It offers features like dry-running protection, thermal overload protection, and alarm signaling, suitable for clean water and wastewater systems. The panel is compact, easy to install and program, and available with various accessories and special configurations.
Préview EP BASIC 1-2 Electronic Control Panel for 1 or 2 Single-Phase or Three-Phase Pumps
The EP BASIC 1-2 is an electronic control panel designed for managing one or two single-phase or three-phase pumps. It offers features like anti-seizing, dry-run protection, and overload protection, with options for remote control and advanced accessories. Suitable for clean and wastewater applications.
Préview EBARA CDA Series Centrifugal Pumps - Technical Specifications and Performance Data
Comprehensive technical data, performance curves, dimensions, and motor specifications for EBARA CDA series centrifugal pumps (50Hz). Includes detailed information on materials, mechanical seals, bearings, and packing for various models.
Préview Multis Verticais EBARA EVMS 1-90tagCatálogo de Produtos de Bombas
Catálogo completo de produtos para multifuncionais verticais EBARA EVMS 1-90tagBombas hidráulicas, detalhando características, aplicações, faixas de desempenho, construção e rede global de vendas. Saiba mais sobre soluções hidráulicas inovadoras, confiabilidade e especificações técnicas.
Préview EBARA 1GP Automatic Pressure Booster Sets - Operating and Maintenance Manual
Comprehensive operating and maintenance manual for EBARA 1GP Automatic Pressure Booster Sets. Covers installation, operation, troubleshooting, and safety guidelines for various models.