Orbit CN-150

Manual do usuário do niple de conduíte Orbit CN-150 de 1-1/2"

Modelo: CN-150

Introdução

This manual provides essential information for the proper installation, usage, and maintenance of the Orbit CN-150 Conduit Chase Nipple. This product is designed to securely connect electrical conduits to enclosures, junction boxes, or other electrical fittings, ensuring a safe and compliant electrical installation. Please read this manual thoroughly before beginning any work.

Informações de segurança

Always prioritize safety when working with electrical components. Failure to follow these safety guidelines may result in property damage, serious injury, or death.

Produto acimaview

The Orbit CN-150 is a 1-1/2 inch conduit chase nipple, a crucial fitting used in electrical installations. It features external threads on one end and a smooth, unthreaded opening on the other, designed to pass through a knockout hole in an electrical box or enclosure. It is typically secured with a locknut to provide a rigid and secure connection point for conduit.

Orbit CN-150 Conduit Chase Nipple 1-1/2" - a close-up view of the threaded metal fitting.

This image displays the Orbit CN-150 Conduit Chase Nipple, a 1-1/2 inch threaded fitting used for securing conduits to electrical boxes or enclosures. The image highlights the external threads and the hexagonal head for tightening.

Configuração e instalação

Follow these steps for proper installation of the Orbit CN-150 Conduit Chase Nipple:

  1. Prepare o recinto: Ensure the electrical box or enclosure has a properly sized knockout hole (1-1/2 inch) for the conduit chase nipple. If not, use an appropriate knockout punch to create one.
  2. Insert the Nipple: Insert the threaded end of the CN-150 conduit chase nipple through the knockout hole from the outside of the electrical box or enclosure.
  3. Secure with Locknut: From the inside of the electrical box, thread a compatible 1-1/2 inch locknut onto the nipple.
  4. Tighten the Connection: Use a wrench or appropriate tool to firmly tighten the locknut against the inside of the enclosure. Ensure the nipple is snug and does not rotate freely. This creates a secure and grounded connection.
  5. Conectar conduíte: Once the chase nipple is secured, a conduit connector can be attached to the external threads of the nipple, allowing for the connection of conduit.

Operating / Functionality

The Orbit CN-150 Conduit Chase Nipple is a passive component designed to provide a secure and stable entry point for electrical conduit into an enclosure. Its primary function is to:

Manutenção

The Orbit CN-150 Conduit Chase Nipple requires minimal maintenance due to its durable construction. However, periodic inspection is recommended to ensure continued safety and performance:

Solução de problemas

While the CN-150 is a simple component, issues can arise from improper installation or environmental factors.

ProblemaPossível causaSolução
Nipple is loose after installationLocknut not tightened sufficiently.Ensure power is off, then re-tighten the locknut firmly with a wrench.
Conduit does not fit onto nipple threadsIncompatible conduit connector or incorrect conduit size.Verify that the conduit connector and conduit are the correct 1-1/2 inch size and type for the nipple.
Corrosion or rust on nippleExposição à umidade ou a agentes corrosivos.If minor, clean and apply a protective coating. If severe, replace the nipple. Consider using corrosion-resistant fittings in such environments.

Especificações

Documentos relacionados - NC-150

Préview Guia de início rápido do controlador de sprinklers Orbit de 12 estações
Um guia de início rápido para o Controlador de Irrigação Orbit de 12 Estações, abrangendo instalação, programação e conexão ao sistema de gerenciamento residencial Lowe's Iris. Inclui instruções para operação manual, atraso por chuva e solução de problemas.
Préview Orbit 1 Dial 1 Outlet Hose Faucet Timer: User Guide and Programming
Learn how to install, program, and use your Orbit 1 Dial 1 Outlet Hose Faucet Timer for efficient garden watering. Includes features, setup, and troubleshooting.
Préview Temporizador para Grifo de Manguera Orbit: Guia de Usuário e Programação
Guia completo para programar e usar o temporizador de Riego Orbit para Grifos de Manguera. Inclui instalação, configuração, funções adicionais e solução de problemas.
Préview Guia do usuário do temporizador de torneira de mangueira de saída Orbit 1 Dial 1
Manual do usuário do temporizador de torneira de mangueira com mostrador de 1 saída Orbit, detalhando programação, recursos como atraso de chuva e irrigação manual, além de solução de problemas.
Préview Manual de Instalação e Uso do Temporizador de Irrigação Orbit WaterMaster
Comprehensive guide for installing and using the Orbit WaterMaster Sprinkler Timer. Covers setup, programming, manual operation, and troubleshooting for various models.
Préview Guia do usuário do temporizador de torneira de mangueira de saída Orbit 1 Dial 4
A comprehensive guide to installing, programming, and operating the Orbit 1 Dial 4 Outlet Hose Faucet Timer, including features like rain delay and manual watering.