Sawo ARI3-90NB-P

Manual do Usuário do Aquecedor de Sauna Elétrico SAWO ARIES ROUND ARI3

Model: ARI3-90NB-P

1. Introdução

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SAWO ARIES ROUND ARI3 Electric Sauna Heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

Produto acimaview

The SAWO ARIES ROUND ARI3 is a high-quality electric sauna heater designed for both home and commercial use. Its vertical cylindrical shape ensures efficient heat distribution and steam generation. The heater features a durable stainless steel casing and an intuitive integrated control panel for ease of use.

SAWO ARIES ROUND ARI3 Electric Sauna Heater

Figure 1: SAWO ARIES ROUND ARI3 Electric Sauna Heater with sauna stones.

Informações de segurança

Always follow local electrical codes and safety regulations. Installation should be performed by a qualified electrician.

2. Configuração e instalação

Desembalagem e inspeção

Carefully unpack the sauna heater and inspect it for any signs of damage during transit. Report any damage to your supplier immediately.

Stone Placement

The ARI3 model can hold up to 60 kg of sauna stones (diameter 5-10 cm). Arrange the stones loosely around the heating elements to allow for proper air circulation. Do not pack stones too tightly. The heating elements are separated from the stones by a special stone spacer to prolong their lifespan.

Close-up of sauna heater base and controls

Figura 2: Close view of the heater's base and integrated controls.

Conexão elétrica

The SAWO ARIES ROUND ARI3 is a multi-voltage heater, supporting either 230V single-phase (fuse: 1x40A) or 400V 3-phase (fuse: 3x16A) installation. Ensure the electrical supply matches the heater's requirements. The connection cable must be type HO7RN-F or equivalent and is not included.

Placement and Safety Distances

The heater is a floor-standing model. Maintain minimum safety distances from walls and ceiling.

Table 1: Minimum Safety Distances
MediçãoDistância
Distância mínima até o teto1200 milímetros
Minimum distance to side walls100 milímetros
SAWO ARIES ROUND ARI3 heater installed in a sauna

Figure 3: Heater installed in a sauna, demonstrating vertical placement.

3. Instruções de operação

Painel de controle integrado

The SAWO ARIES ROUND ARI3 features a convenient built-in control panel with an intuitive interface. The illuminated rotary knobs allow for easy adjustment even in low light conditions. The timer and thermostat controls can be switched sides for user convenience.

Sauna heater with wooden guard ring accessory

Figure 4: Heater with an optional wooden guard ring, highlighting the integrated controls at the base.

Configurando o temporizador

The timer has an operating time of 1 to 4 hours and a preset time function of 1 to 8 hours.

  1. Turn the timer knob to select the desired operating duration.
  2. For a delayed start, use the preset time function to set when the heater should begin operation.

Ajustando a temperatura

The thermostat automatically maintains the selected temperature.

  1. Turn the thermostat knob to set your desired sauna temperature.
  2. The heater will cycle on and off to maintain this temperature.

Generating Steam

You can generate steam by pouring water onto the hot sauna stones, not only from the top but also from the sides due to the heater's efficient cylindrical design. Use only clean water.

4. Manutenção

Limpeza

Ensure the heater is completely cool and disconnected from power before cleaning. Wipe the stainless steel casing com anúncioamp pano. Não use produtos de limpeza abrasivos ou solventes.

Sauna Stone Replacement

Sauna stones should be inspected regularly and replaced when they start to crumble or lose their porous structure. This typically occurs every 1-2 years depending on usage. Replacing stones ensures efficient heating and proper steam generation.

Close-up of sauna stones in the heater

Figura 5: Close view of the sauna stones within the heater's stainless steel grid.

5. Solução De Problemas

If you encounter issues with your SAWO ARIES ROUND ARI3 heater, refer to the following common problems and solutions. For more complex issues, contact a qualified service technician.

Tabela 2: Guia de solução de problemas
ProblemaPossível causaSolução
O aquecedor não aqueceNo power supply; tripped circuit breaker; faulty heating element; thermostat set too low.Check power connection and circuit breaker. Ensure thermostat is set correctly. If elements are faulty, contact service.
Sauna not reaching desired temperatureInsufficient heating time; sauna room too large for heater; poor insulation; stones packed too tightly.Allow more time for heating. Verify sauna room volume is within heater's capacity (8-13 m³). Rearrange stones for better airflow.
Excessive steam or water drippingToo much water poured on stones; stones are too old/crumbling.Pour less water. Replace old sauna stones.

6. Especificações técnicas

Table 3: SAWO ARIES ROUND ARI3-90NB-P Specifications
RecursoDetalhe
ModeloARI3-90NB-P
Potência de saída9.0 kW
Dimensões (A x L)930 mm x 300 mm
Peso14 kg
Tipo de instalaçãoChão de pé
Capacidade máxima de pedras60 kg (pedras Ø 5-10 cm)
Recommended Sauna Room Size8-13 m³
Volumetage opções230V 1-phase (1x40A fuse) or 400V 3-phase (3x16A fuse)
MaterialAço inoxidável
Painel de controleIntegrated, illuminated timer (1-4h operation, 1-8h preset) and thermostat

7. Garantia e Suporte

Informações de garantia

The SAWO ARIES ROUND ARI3 heater comes with a manufacturer's warranty:

Please retain your proof of purchase for warranty claims. The warranty does not cover sauna stones or silicone connection cables, as these are not included with the heater.

Suporte ao cliente

For technical assistance, spare parts, or warranty inquiries, please contact your local SAWO distributor or the point of purchase.

Fabricante: Sawo
Número do modelo: ARI3-90NB-P

Documentos relacionados - ARI3-90NB-P

Préview Manual do controlador de potência Saunova 2.0 - SAWO
Manual do usuário abrangente para o controlador de potência SAWO Saunova 2.0, detalhando instalação, operação, precauções de segurança e especificações técnicas para sistemas de aquecimento de sauna.
Préview Diagramas de instalação e distâncias de segurança do aquecedor SAWO Cirrus
Diagramas de instalação completos e especificações de distância mínima de segurança para aquecedores SAWO Cirrus, abrangendo modelos com controle separado e integrado. Guia essencial para uma instalação correta.
Préview SAWO Glass Front Sauna Room Assembly Manual
This official assembly manual from SAWO guides users through the complete installation process for their Glass Front Sauna Rooms. It features detailed parts lists, step-by-step assembly instructions, electrical layout diagrams, and essential maintenance tips for models like the 1414LS/RS and 2020ML.
Préview Manual do usuário do aquecedor de torre redondo SAWO
Este manual do usuário fornece instruções detalhadas para a instalação, operação e manutenção do aquecedor de torre redondo SAWO. Ele abrange precauções de segurança, especificações técnicas, solução de problemas e peças de reposição.
Préview Manual da Unidade de Controle Infravermelho SAWO 2.0: Guia de Instalação e Operação
Manual do usuário completo para a unidade de controle SAWO Infrared 2.0. Inclui instruções detalhadas sobre instalação, operação, diretrizes de segurança e solução de problemas para salas de sauna infravermelha.
Préview SAWO Nordex Mini Aquecedor Käyttöohjeet e Käyttöopas
Tutustu SAWO Nordex Mini -saunakiukaan yksityiskohtaisiin käyttöohjeisiin. Tämä opas kattaa asennuksen, turvallisuusohjeet, käytön, huollon e vianetsinnän suomeksi e englanniksi.