Wilo Stratos PICO plus 25/1-3-130

Wilo Stratos PICO plus 25/1-6-130 High-Efficiency Heating Circulation Pump

Manual do usuário

Model: Stratos PICO plus 25/1-3-130

1. Introdução

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wilo Stratos PICO plus high-efficiency heating circulation pump. Please read these instructions carefully before installation and initial operation. Keep this manual for future reference.

The Wilo Stratos PICO plus is designed as a circulation pump for hot water heating systems and various climate control applications. It features advanced technology for energy efficiency and ease of use.

2. Informações de segurança

Always observe the following safety instructions to prevent personal injury and damage to the equipment:

  • Installation and maintenance must only be carried out by qualified personnel in accordance with local regulations and standards.
  • Certifique-se de que a fonte de alimentação esteja desconectada antes de qualquer trabalho de instalação ou manutenção.
  • The pump operates with electrical voltage. Avoid contact with live parts.
  • Do not operate the pump if it is damaged or if the electrical cable is faulty.
  • Proteja a bomba do gelo.
  • Utilize equipamento de proteção individual (EPI) adequado durante a instalação e manutenção.

3. Configuração e instalação

The Wilo Stratos PICO plus pump is designed for comfortable replacement and compact installation. It features a Wilo Connector for quick and tool-free electrical wiring.

3.1 Montagem da Bomba

Mount the pump in the heating system piping. Ensure the flow direction arrow on the pump housing matches the system's flow direction. The pump can be installed horizontally or vertically, but the motor shaft must always be horizontal.

Wilo Stratos PICO plus pump installed in a heating system

Figure 1: Wilo Stratos PICO plus pump installed in a typical heating system setup, showing its compact integration with existing pipes and gauges.

Two Wilo Stratos PICO plus pumps installed in a heating system

Figure 2: Two Wilo Stratos PICO plus pumps integrated into a larger heating system, demonstrating their versatility and ease of installation in various configurations.

3.2 Conexão elétrica

The Wilo Connector simplifies electrical wiring. Ensure the power supply matches the pump's specifications (230 Volts). Connect the pump to a properly grounded electrical circuit.

Wilo Stratos PICO plus pump with Wilo Connector

Figura 3: Close view of the Wilo Stratos PICO plus pump, highlighting the Wilo Connector for electrical wiring and the insulation shell.

The pump comes with an insulation shell (Dämmschale) included in the scope of delivery to minimize heat loss.

4. Instruções de operação

The Wilo Stratos PICO plus features an intuitive LC display and precise setting options for optimal performance.

4.1 LC Display and Controls

The large LC display shows current power consumption, cumulative kWh, and volume flow. Functions and modes are displayed on the LC display and activated directly via the green button technology.

Wilo Stratos PICO plus LC display

Figura 4: Detalhado view of the Wilo Stratos PICO plus LC display, showing various operational parameters and settings, including power consumption and volume flow.

Wilo Stratos PICO plus LC display close-up

Figure 5: Close-up of the Wilo Stratos PICO plus LC display, providing a clear view of the digital readouts for power (W), volume flow (m³/h), and cumulative energy consumption (kWh).

4.2 Operating Modes and Functions

  • Optimized Dynamic Adapt Function: Automatically adjusts pump performance to the system's requirements, ensuring energy efficiency.
  • Manual De-aeration Routine: Helps to remove air from the pump and system, preventing noise and ensuring proper operation.
  • Automatic Deblocking Function: Prevents the pump from seizing up after long periods of inactivity.

Refer to the on-screen menu for detailed navigation and setting adjustments using the green control button.

5. Manutenção

The Wilo Stratos PICO plus is designed for low maintenance. Regular checks can help ensure its longevity and efficient operation.

  • Inspeção visual: Periodically check the pump for any signs of leaks, corrosion, or damage.
  • Pressão do sistema: Ensure the heating system pressure is within the recommended range.
  • Remoção de ar: Utilize the manual de-aeration routine if you notice gurgling noises or reduced heating performance.
  • Limpeza: Keep the exterior of the pump clean and free from dust and debris.

Para qualquer manutenção ou reparo complexo, entre em contato com um técnico de serviço qualificado.

6. Solução De Problemas

If you encounter issues with your Wilo Stratos PICO plus pump, refer to the following common troubleshooting steps:

  • Bomba não está funcionando:
    • Verifique a fonte de alimentação e o disjuntor.
    • Ensure the electrical connection is secure.
    • Verify the pump is not in a standby or off mode on the display.
  • Noisy Operation / Gurgling:
    • Perform the manual de-aeration routine to remove trapped air.
    • Check system pressure.
  • Desempenho de aquecimento reduzido:
    • Check pump settings on the LC display.
    • Ensure there is no air in the system.
    • Verify system pressure and flow.
  • Pump Seized:
    • The automatic deblocking function should prevent this. If it occurs, contact a qualified technician.

If the problem persists after attempting these steps, contact Wilo customer support or a certified service professional.

7. Especificações

Below are the technical specifications for the Wilo Stratos PICO plus 25/1-3-130 pump:

RecursoValor
FabricanteWILO SE
Dimensões do produto (C x L x A)15.6 x 18.6 x 11.6 cm
Peso2.04 quilogramas
Número do modelo do itemStratos PICO plus 25/1-3-130
CorVerde
EstiloModerno
MaterialMetal, Carbon Steel
Fonte de energiaCabo elétrico
Volumetage230 Volts
Quantidade de itens1
Pilhas incluídasNão
Pilhas necessáriasNão
Disponibilidade de peças de reposiçãoInformação indisponível
Código Internacional de Artigos04048482754451
Wilo Stratos PICO plus performance curve

Figure 6: Performance curve for Wilo Stratos PICO plus pumps, illustrating head (H/m) versus flow rate (Q/m³/h) for different models (15, 25, 30/1-6 and 15, 25, 30/1-4).

8. Garantia e Suporte

For warranty information, please refer to the documentation provided with your purchase or contact your local Wilo representative. For technical support, spare parts, or service, please visit the official Wilo website ou entre em contato com o departamento de atendimento ao cliente.

Documentos relacionados - Stratos PICO plus 25/1-3-130

Préview Wilo-Stratos PICO Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining the Wilo-Stratos PICO high-efficiency circulation pump for heating systems. Includes safety, technical data, and operational procedures.
Préview Bomba circuladora Wilo-Stratos PICO: Guia de instalação rápida
Este documento fornece um guia rápido para a bomba de circulação Wilo-Stratos PICO, projetada para sistemas de aquecimento de água quente. Inclui informações essenciais de instalação e operação, com referência ao manual de instruções completo.
Préview Wilo-Stratos PICO-Z High-Efficiency Circulator Pump: Installation and Operating Instructions
Detailed installation and operating manual for the Wilo-Stratos PICO-Z high-efficiency circulator pump (Article No. 4258257). This guide covers safety, technical specifications, installation, operation, commissioning, maintenance, and troubleshooting for drinking water recirculation systems in industrial and building services applications.
Préview Wilo-Stratos PARA-C/-CZ Installation and Operating Instructions
Comprehensive installation and operating instructions for the Wilo-Stratos PARA-C/-CZ high-efficiency circulation pump. Covers safety, transport, usage, product data, description, installation, commissioning, maintenance, and troubleshooting.
Préview Catálogo de Wilo para sua empresa: отопление, водоснабжение, водоотведение
Use o circuito de operação Wilo para o sistema de operação, sucção e sucção. Informações para fabricantes e montadores.
Préview Manual de Instalação e Operação da Bomba de Circulação de Alta Eficiência Wilo-Stratos PARA-C/-CZ
Guia completo de instalação, operação e manutenção da bomba de circulação de alta eficiência Wilo-Stratos PARA-C/-CZ, abrangendo segurança, dados técnicos, instalação e resolução de problemas.