DMP716

Manual do Usuário do Módulo de Expansão de Saída DMP 716

Modelo: 716

1. Introdução

The DMP 716 Output Expansion Module is designed to extend the output capabilities of compatible DMP control panels. It provides additional programmable relays and annunciator outputs, facilitating integration with various external devices and systems. This manual provides essential information for the proper installation, operation, and maintenance of the 716 module.

2. Recursos do Produto

  • Four programmable Form C (SPDT) relays for versatile control applications.
  • Four open collector annunciator outputs for signaling and status indication.
  • Designed for seamless integration with all LX-Bus circuits, ensuring reliable communication.
  • Compact and durable design suitable for various installation environments.

3. Configuração e instalação

Before beginning installation, ensure all power to the control panel and associated devices is disconnected. Refer to the control panel's installation guide for specific wiring diagrams and power requirements.

3.1 Montagem

The 716 module should be mounted securely within the control panel enclosure or a suitable auxiliary enclosure. Use the provided mounting holes to fasten the module to a flat surface, ensuring adequate ventilation.

3.2 fios

Connect the 716 module to the control panel's LX-Bus terminals. Observe proper polarity for power connections. Connect external devices to the Form C relays and open collector annunciator outputs as required by your system design. Ensure all connections are secure and insulated.

DMP 716 Output Expansion Module with its cover removed, showing the circuit board.

This image displays the DMP 716 Output Expansion Module. The main component is a green circuit board populated with various electronic components, including relays and integrated circuits, mounted within a white plastic housing. To the right, the module's white plastic cover is shown detached, indicating the internal view do dispositivo.

3.3 Configuração

After physical installation, configure the 716 module's outputs through the control panel's programming interface. Refer to your control panel's programming manual for detailed instructions on assigning functions to the relays and annunciator outputs.

4. Operação do Módulo

The DMP 716 module operates under the control of the connected DMP control panel. Its relays and annunciator outputs will activate or deactivate based on the programming and events within the security or automation system.

  • Saídas de relé: The four Form C (SPDT) relays can be programmed to switch external circuits (e.g., lights, sirens, door locks) based on system events like alarms, arming status, or specific zone conditions.
  • Annunciator Outputs: The four open collector outputs provide low-current signaling for devices such as LEDs or small buzzers, indicating system status or specific event occurrences.

Always ensure that the connected devices' power requirements do not exceed the module's output specifications.

5. Manutenção

The DMP 716 module is designed for reliable, long-term operation with minimal maintenance. Regular inspection is recommended to ensure optimal performance.

  • Inspeção visual: Periodically inspect the module for any signs of physical damage, loose connections, or corrosion.
  • Limpeza: Se necessário, limpe delicadamente a parte externa do módulo com um pano macio e seco. Não utilize produtos de limpeza líquidos ou solventes.
  • Atualizações de firmware: Consult DMP technical support or your installer for information regarding any available firmware updates for your control panel that may affect module operation.

6. Solução De Problemas

If you experience issues with the DMP 716 module, consider the following troubleshooting steps:

  • Módulo não responde:
    • Verify that the LX-Bus connections are secure and correctly polarized.
    • Check the control panel's power supply.
    • Ensure the module is properly addressed or recognized by the control panel in its programming.
  • Saída não ativada:
    • Confirm the output is correctly programmed in the control panel for the desired event.
    • Check the wiring to the external device connected to the output.
    • Verify the external device is functioning correctly and its power requirements are met.
    • Ensure the load connected to the relay does not exceed its maximum current rating.
  • Operação intermitente:
    • Inspect all wiring for loose connections or damaged insulation.
    • Check for potential electrical interference from nearby equipment.

If problems persist after attempting these steps, contact your installer or DMP technical support.

7. Especificações

AtributoValor
FabricanteDMP
Número do modelo do produto716
Dimensões (C x L x A)20.32 x 15.24 x 5.08 cm
Peso453.59 g
Saídas de relé4 x Form C (SPDT) programmable
Saídas do Anunciador4 x Open Collector
Compatibilidade de ônibusÔnibus LX

8. Garantia e Suporte

For warranty information regarding your DMP 716 Output Expansion Module, please refer to the documentation provided at the time of purchase or contact your authorized DMP dealer. DMP products are typically covered by a limited warranty against defects in materials and workmanship.

For technical support, installation assistance, or advanced troubleshooting, please contact your security system installer or visit the official DMP webSite com recursos de suporte e informações de contato.

Documentos relacionados - 716

Préview Guia de instalação do módulo de expansão de saída DMP 716
Guia de instalação do módulo de expansão de saída DMP 716, detalhando suas características, montagem, fiação, endereçamento e programação para painéis de alarme das séries XR150/XR550. Inclui especificações e informações de conformidade.
Préview Guia de instalação do módulo de expansão de zona DMP 712-8
Guia de instalação completo para o módulo de expansão de zona DMP 712-8. Saiba mais sobre seus recursos, compatibilidade com os painéis DMP XT30, XT50, XR150 e XR550, instruções de fiação para LX-Bus e Keypad Bus, endereçamento do módulo e certificações de conformidade.
Préview Guia de instalação do módulo de expansão de zona DMP 711S
Comprehensive installation guide for the DMP 711S Zone Expansion Module, detailing setup, wiring, programming, and compliance for DMP XT30/XT50 and XR150/XR550 series alarm panels.
Préview DMP 710 Bus Splitter/Repeater Module Installation Guide | Expand LX-Bus & Keypad Bus
Learn how to install and configure the DMP 710 Bus Splitter/Repeater Module. This guide covers mounting, wiring, and voltage drop considerations for expanding LX-Bus and Keypad Bus systems in security applications.
Préview Guia de Instalação do Módulo de Expansão de Zona 712-8INT | DMP
Guia de instalação completo para o módulo de expansão de zona DMP 712-8INT. Aprenda como montar, conectar e configurar o endereçamento do módulo para os painéis de segurança das séries DMP XT30INT, XT50INT, XR150INT e XR550INT.
Préview Guia de Instalação do Módulo Repetidor / Divisor de Barramento DMP 710
Installation guide for the DMP 710 Bus Splitter/Repeater Module, detailing its use as a splitter, repeater, and junction box for LX-Bus and Keypad Bus circuits. Includes wiring instructions, voltage drop measurements, and compatibility information.