Danfoss EV251B

Manual de Instruções da Válvula Solenoide Danfoss EV251B

Model: EV251B

Introdução

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss EV251B Solenoid Valve. Please read this manual thoroughly before attempting any installation or operation procedures. Retain this manual for future reference.

Informações de segurança

Always observe general safety precautions when working with electrical and pressurized systems. Failure to follow these instructions may result in property damage, serious injury, or death.

Produto acimaview

The Danfoss EV251B is a 2/2-way assisted lift operated solenoid valve designed for various industrial applications. It features a G1 outlet connection type and an NBR seal, suitable for specific media and temperature ranges. The valve operates on a 230V, 50Hz power supply.

Válvula solenóide Danfoss EV251B

Figura 1: Danfoss EV251B Solenoid Valve. This image displays the brass valve body with a blue solenoid coil attached to the top. A black square gasket and a screw are shown in the foreground, indicating components for assembly or sealing.

Especificações

ModeloEV251B
Número da peça032U538331
Tipo2/2-way, Assisted Lift Operated
Tamanho do Orifício7/8 de polegada
Tipo de conexãoG1 (Outlet)
Material de vedaçãoNBR (Borracha de Nitrila Butadieno)
Volumetage230 V CA
Freqüência50Hz
MarcaDanfoss
FabricanteKempston Controls
ASINB07HCDVTQN

Configuração e instalação

1. Verificações de pré-instalação

2. Montagem

  1. Mount the valve in a position that allows for easy access for maintenance.
  2. Ensure the valve is installed vertically with the coil pointing upwards for optimal performance, unless otherwise specified for specific applications.
  3. Use appropriate pipe sealant on threaded connections to prevent leaks. Do not overtighten.

3. Conexão elétrica

Instruções de operação

The Danfoss EV251B is an assisted lift operated valve. This means it requires a minimum pressure differential to fully open or close, but can operate from zero differential pressure due to the assisted lift mechanism. When the coil is energized, the valve opens, allowing fluid flow. When de-energized, the valve closes, stopping flow.

Manutenção

Regular maintenance ensures optimal performance and extends the lifespan of the valve. Always de-energize the coil and depressurize the system before performing any maintenance.

1. Limpeza

2. Inspeção

Solução de problemas

ProblemaPossível causaSolução
A válvula não abreNo power to coil; Incorrect voltage; Coil failure; Obstruction in valve.Check power supply and connections; Verify voltage; Replace coil; Inspect and clean valve internals.
A válvula não fechaDebris preventing closure; Worn seal; Coil remains energized.Clean valve internals; Replace seal; Check electrical circuit for continuous power.
Vazamento na válvulaLoose connections; Damaged seals; Cracked valve body.Tighten connections; Replace seals; Replace valve if body is cracked.

Informações de garantia

Danfoss products are manufactured to high-quality standards. This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to your purchase documentation or contact Danfoss customer support for detailed warranty information.

Suporte ao cliente

For technical assistance, spare parts, or further inquiries regarding your Danfoss EV251B Solenoid Valve, please contact your local Danfoss representative or visit the official Danfoss website. Ensure you have the model number (EV251B) and part number (032U538331) available when seeking support.

Você pode encontrar mais informações e detalhes de contato no site. Danfoss Store.

Documentos relacionados - EV251B

Préview Guia de Montagem Danfoss EV251B NC
Guia oficial de montagem da válvula solenoide Danfoss EV251B NC. Saiba mais sobre a identificação da válvula, instalação correta, montagem e substituição da bobina e etapas comuns de solução de problemas. Inclui especificações técnicas e informações de suporte.
Préview Guia de Instalação da Válvula Solenoide Danfoss EV251B
Guia de instalação completo para a válvula solenoide Danfoss tipo EV251B, detalhando as conexões elétricas e mecânicas, etapas de operação e especificações técnicas.
Préview Guia de instalação da válvula solenóide de 100 etapas Danfoss ICLX 150-2
Comprehensive installation, maintenance, and technical specifications for the Danfoss ICLX 100-150 2-step solenoid valve, covering operation, assembly, and troubleshooting.
Préview Danfoss ICF Valve Station: Technical Data and Applications
Comprehensive data sheet for Danfoss ICF valve stations (models ICF 15, 20, 25, 50, 65), detailing features, technical specifications, function modules, material data, connection types, and application examples for industrial refrigeration.
Préview Guia de instalação da válvula solenóide Danfoss EV220B 65-100
Comprehensive installation guide for Danfoss EV220B 65, 80, and 100 solenoid valves, covering product contents, specifications, installation steps, and maintenance recommendations.
Préview Danfoss EV220B 15 - EV220B 50 Solenoid Valve Installation Guide
Step-by-step installation guide for Danfoss EV220B 15 and EV220B 50 solenoid valves. Includes technical specifications, safety information, and operational details.