CISA 60450.03.97

CISA Serie 604 Rack and Pinion Door Closer - Model 60450.03.97

Manual de instruções

1. Introdução

This manual provides detailed instructions for the installation, operation, and maintenance of the CISA Serie 604 Rack and Pinion Door Closer, model 60450.03.97. This door closer is designed to provide effective and reliable door control for both residential and commercial applications, ensuring smooth and secure door closure.

The CISA Serie 604 features adjustable closing force (EN 2-4) and is suitable for doors weighing up to 85 kg and up to 1100 mm in width. It offers independent adjustments for closing speed and final latching action, ensuring optimal performance in various environments. Its compact design allows for seamless integration with diverse architectural styles.

2. Informações de segurança

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in injury or damage to the product or property.

  • Certifique-se de que todos os componentes estejam presentes e sem danos antes de iniciar a instalação.
  • Always use appropriate tools and safety equipment during installation.
  • Do not attempt to modify the door closer. Any modifications will void the warranty and may compromise safety.
  • Mantenha crianças e animais de estimação afastados da área de instalação.
  • Ensure the door closer is securely fastened to prevent accidental detachment.
  • Adjustments should only be made by qualified personnel to prevent improper operation or damage.

3. Produto acabadoview e Componentes

The CISA Serie 604 door closer consists of the main body, an arm assembly, and adjustment valves. It is supplied with all necessary fixing screws and a mounting template for straightforward installation.

Fechar-se view of the CISA Serie 604 door closer showing the adjustment screws for closing speed and final latching.

Figura 1: Fechar-se view of the CISA Serie 604 door closer, highlighting the two adjustment screws for precise control over closing speed and final latching action. The CISA logo is visible at the bottom left.

Os principais componentes incluem:

  • Corpo principal: Contains the rack and pinion mechanism and hydraulic fluid.
  • Montagem do braço: Connects the door closer to the door frame or door.
  • Adjustment Valves: Two independent valves for controlling closing speed and final latching.
  • Mounting Plate/Template: For accurate positioning during installation.
  • Parafusos de fixação: For secure attachment.

4. Configuração e instalação

The CISA Serie 604 door closer is designed for quick installation and can be mounted on both right-hand and left-hand doors, for both pull-side and push-side applications. A mounting template is provided to simplify the process.

4.1. Verificações de pré-instalação

  • Verify the door weight and width are within the specified limits (max 85 kg, max 1100 mm).
  • Determine the mounting position (door or frame) and orientation (pull-side or push-side) based on your door type and desired opening angle.
  • Ensure the mounting surface is strong enough to support the door closer.

4.2. Etapas de montagem

  1. Posicionamento: Use the provided mounting template to mark the drilling points on the door or door frame.
  2. Perfuração: Faça furos piloto nas posições marcadas.
  3. Attach Main Body: Securely fasten the main body of the door closer using the supplied fixing screws.
  4. Montar o braço: Attach the arm assembly to the door closer and the door frame/door, following the specific instructions for your chosen mounting type (pull-side or push-side). Ensure all connections are tight.
Technical drawing of the CISA Serie 604 door closer with detailed dimensions in millimeters.

Figura 2: Technical drawing illustrating the dimensions and mounting points of the CISA Serie 604 door closer. All measurements are in millimeters, providing precise guidance for installation.

5. Instruções de operação e ajustes

The CISA Serie 604 door closer allows for independent adjustment of two key functions: closing speed and final latching action. These adjustments are crucial for optimal door performance and safety.

5.1. Adjustment Valves

The door closer features two adjustment valves, typically labeled '1' and '2' or similar, as shown in Figure 1. These valves control different phases of the door's closing cycle:

  • Válvula 1 (Velocidade de Fechamento): Controls the speed of the door from its fully open position until approximately 15 degrees from closure. Turning the valve clockwise decreases the speed (slower closing), and counter-clockwise increases the speed (faster closing).
  • Valve 2 (Final Latching Action / Backcheck): Controls the speed of the door for the final 15 degrees of closure, ensuring the door latches securely without slamming. It can also provide a backcheck function to prevent the door from opening too quickly or forcefully. Turning clockwise decreases the latching speed/increases backcheck, counter-clockwise increases latching speed/decreases backcheck.
Diagram showing the adjustment sectors for closing speed (green) and final latching action (red) on the CISA Serie 604 door closer.

Figura 3: This diagram illustrates the two distinct adjustment sectors. The green sector (up to 80 degrees) represents the main closing speed, while the red sector (final 15 degrees) indicates the final latching action, both independently adjustable.

5.2. Making Adjustments

  • Use a suitable screwdriver to turn the adjustment valves.
  • Make small adjustments (quarter turns) at a time and test the door's closing action after each adjustment.
  • Do not overtighten or loosen the valves excessively, as this can damage the hydraulic mechanism.
  • Aim for a smooth, controlled closing action that allows the door to latch without excessive force or speed.

6. Manutenção

The CISA Serie 604 door closer is designed for long-term, maintenance-free operation. However, periodic checks can help ensure its continued performance and extend its lifespan.

  • Inspeção anual: Annually inspect the door closer and its mounting screws for any signs of loosening, wear, or damage.
  • Limpeza: Keep the door closer clean from dust and debris. Use a soft, damp Use um pano para limpeza. Evite produtos de limpeza abrasivos ou solventes.
  • Lubrificação: No internal lubrication is required. Do not attempt to lubricate any part of the hydraulic mechanism.
  • Montagem do braço: Check the arm assembly for any bending or damage. Ensure all pivot points move freely without excessive play.

If any significant wear or damage is observed, contact a qualified technician for inspection and repair or replacement.

7. Solução De Problemas

This section addresses common issues you might encounter with your CISA Serie 604 door closer.

ProblemaPossível causaSolução
A porta bate com força.Closing speed or final latching speed is too fast.Adjust Valve 1 (closing speed) and/or Valve 2 (final latching) clockwise in small increments until desired speed is achieved.
A porta fecha muito lentamente.Closing speed is too slow.Adjust Valve 1 (closing speed) counter-clockwise in small increments.
A porta não fecha corretamente.Final latching speed is too slow or insufficient.Adjust Valve 2 (final latching) counter-clockwise in small increments to increase latching force/speed.
Vazamento de óleoVedações ou componentes internos danificados.This indicates a serious issue. The unit cannot be repaired by the user. Contact a qualified technician or replace the unit.
Door closer makes unusual noisesLoose mounting screws or damaged internal components.Check and tighten all mounting screws. If noise persists, contact a qualified technician.

8. Especificações

RecursoDetalhe
Número do modelo60450.03.97
MarcaCISA
TipoRack and Pinion Door Closer
Adjustable Closing ForceEN 2-4
Máx. Peso da porta85 kg
Largura máxima da porta1100 milímetros
Uso recomendadoPortas residenciais e comerciais
Dimensões (C x L x A)18 cm x 4 cm x 6 cm
Peso1.44 kg
MaterialAluminum (Body), Steel (Arm)
TerminarCinza Alumínio
Tipo de instalaçãoMontado na superfície

9. Garantia e Suporte

For information regarding warranty coverage, please refer to the documentation provided at the time of purchase or contact your retailer. CISA products are manufactured to high-quality standards, and proper installation and maintenance ensure long-lasting performance.

For technical support, spare parts, or service inquiries, please contact CISA customer service or your authorized dealer. Ensure you have your product model number (60450.03.97) and purchase details available when contacting support.

Documentos relacionados - 60450.03.97

Préview Sensor CISA Mito: Instalação e Manual do Usuário
Guia completo para a fechadura com sensor CISA Mito, detalhando instalação, operação, manutenção, segurança e solução de problemas. Inclui especificações técnicas e acessórios.
Préview Guia de Instalação do Microinterruptor de Pressão CISA - Modelo 06A95060
Instruções oficiais de instalação para o microinterruptor de pressão CISA (Modelo 06A95060), um componente para dispositivos de saída de emergência. Inclui etapas para fixação no suporte e verificação de funcionamento.
Préview Guia de Instalação do Microinterruptor CISA Touch
Instruções oficiais de instalação para o microinterruptor CISA Touch (Art. 06A95050), detalhando a desmontagem do suporte do braço, a montagem do microinterruptor e as verificações operacionais.
Préview Guida all'Installazione CISA: Comandi Esterni per Maniglioni Antipanico (Art. 07A78.xx)
Instruções dettagliate per l'installazione dei comandi esterni CISA per maniglioni antipanico, modello Art. 07A78.xx. Incluir configurações, segunda-feirataggio e specifiche tecniche.
Préview Guia de Instalação da Tampa de Fechaduras Elétricas CISA
Folha de instruções para tampas de fechadura elétrica CISA (Art. 06A98120.XX), detalhando as configurações de instalação e os procedimentos de montagem para diversos tipos de batentes de porta. Inclui orientações sobre a seleção de placas e parafusos adequados.
Préview Adaptador CISA 06A98910 para adaptação de dispositivos de acesso rápido - Guia de instalação
Este documento fornece instruções de instalação para o adaptador CISA 06A98910 para adaptação de dispositivos de acesso rápido. Ele abrange a montagem, as especificações de corte e as verificações finais para diversas configurações de portas.