1. Introdução
Thank you for choosing the Yuwell YX303 Fingertip Pulse Oximeter. This device is designed for non-invasive spot-check measurement of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate. It is suitable for use in hospitals, homecare, outdoor activities, and sports. Please read this manual carefully before use to ensure safe and effective operation.

Image 1.1: The Yuwell YX303 Fingertip Pulse Oximeter. This image shows the compact device, typically with a display screen and a finger insertion area.
2. Informações de segurança
Importante: This device is intended for non-medical use and is not a substitute for professional medical advice or diagnosis. Consult your physician for any medical concerns.
- Não use o oxímetro em um ambiente de ressonância magnética ou tomografia computadorizada.
- Não utilize o oxímetro em situações que exijam monitoramento contínuo.
- Keep the device away from children. Small parts may be a choking hazard.
- Do not use the oximeter on the same arm as a blood pressure cuff or arterial catheter.
- Avoid placing the oximeter on fingers with nail polish, artificial nails, or excessive dirt, as this may affect accuracy.
- Ensure the finger is clean and dry before use.
3. Produto acabadoview
3.1. Principais características
- Low power consumption, simple to operate, light, and portable.
- Oxygen saturation (SpO2) and Pulse Rate (PR) display.
- Automatic power-off in 8 seconds when no finger is detected.
- Pulse strength indicator.
- Strong anti-interference capability.
3.2. Modos de exibição
The device features an OLED display. It shows:
- Oxygen Saturation (SpO2) percentage.
- Pulse Rate (BPM).
- Pulse bar graph.
4. Configuração
4.1. Instalação da bateria
- Abra a tampa do compartimento da bateria na parte traseira do dispositivo.
- Insert two (2) AAA 1.5V alkaline batteries, ensuring correct polarity (+ and -).
- Feche bem a tampa do compartimento da bateria.
O dispositivo opera dentro de um voltagFaixa de 2.6V a 3.6V.
5. Instruções de operação
- Verifique se o oxímetro tem pilhas instaladas.
- Abra o clamp do oxímetro.
- Insert one finger into the rubber opening of the oximeter, ensuring the finger is placed correctly and comfortably.
- Solte o clampO oxímetro ligará automaticamente e iniciará a medição.
- Mantenha a mão imóvel durante a medição. Movimentos podem afetar a precisão.
- Read the SpO2 and Pulse Rate values displayed on the OLED screen.
- After removing your finger, the device will automatically power off after approximately 8 seconds.
5.1. Measurement Accuracy Considerations
- Saturação de oxigênio: Accuracy is ±2% for readings between 70% and 99%. For readings below 70%, accuracy is not defined.
- Taxa de pulso: Accuracy is ±1% or ±1 BPM, whichever is greater.
- Weak Perfusion: The oximeter can accurately display oxygen saturation and pulse rate even with a pulse filling degree as low as 0.6%.
- Light Interference: Compared to measurements in a dark room, the deviation in oxygen saturation under natural light and illuminated conditions is less than ±1%.
6. Manutenção
6.1. Limpeza
- Limpe a superfície do oxímetro com um pano macio.ampened with medical alcohol (75% ethanol) or isopropyl alcohol.
- Não mergulhe o dispositivo em água ou em qualquer solução de limpeza.
- Certifique-se de que o dispositivo esteja completamente seco antes de reutilizá-lo.
6.2. Armazenamento
- Guarde o oxímetro em local fresco e seco, longe da luz solar direta e de temperaturas extremas.
- Remova as pilhas se o dispositivo não for usado por um longo período para evitar vazamento das mesmas.
7. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| Sem exibição após ligar | As pilhas estão descarregadas ou instaladas incorretamente. | Substitua as pilhas ou reinstale-as observando a polaridade correta. |
| Leituras imprecisas | Finger not inserted properly; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm finger. |
| Mensagem de erro "Dedo fora" ou similar | Dedo não detectado ou posicionado incorretamente. | Ensure finger is fully inserted into the sensor. |
8. Especificações
| Parâmetro | Valor |
|---|---|
| Modo de exibição | Tela OLED |
| Faixa de medição de SpO2 | 70% ~ 100% |
| Precisão de SpO2 | ±2% (70%~99%), undefined (<70%) |
| Faixa de medição da frequência de pulso | 25~250BPM |
| Precisão da frequência de pulso | ±1% or ±1 BPM (whichever is greater) |
| Fonte de energia | 2 pilhas alcalinas AAA de 1.5 V |
| Volumetage Alcance | 2.6V ~ 3.6V |
| Consumo de energia | Menos de 30 mA |
| Weak Perfusion Measurement | SpO2 and PR can be displayed when pulse filling degree is 0.6% |
| Desligamento automático | After 8 seconds of no finger use |
| Fabricante | YUWELL |
| Número do modelo | YX303 (Internal Item No: 31681163949) |
| Dimensões da embalagem | 11.52 x 7.21 x 3.8 cm |
| Peso | 300 g (incluindo a embalagem) |
9. Garantia e Suporte
For warranty information and customer support, please refer to the documentation provided with your purchase or contact your retailer. Keep your purchase receipt as proof of purchase.