This manual provides comprehensive instructions for the installation, operation, and maintenance of your Emerson 1E78-140 Non-Programmable Heat Only Thermostat. Please read this manual thoroughly before installation and use to ensure proper function and safety.
The Emerson 1E78-140 is designed for use with most single-stage heat-only systems, including 24-volt and millivolt systems. It is not compatible with electric baseboard heat or certain other systems.
Configuração e instalação
Ferramentas necessárias
- Chave de fenda
- Faça furos (se forem necessários novos furos de montagem)
- Decapadores de fios (se necessário)
Removendo seu antigo termostato
- Turn off power to your heating system at the main fuse or circuit breaker panel.
- Remova a tampa do seu termostato antigo.
- Take a photo of the existing wiring connections for reference.
- Disconnect the wires from the old thermostat terminals, noting which wire was connected to each terminal.
- Remove the old thermostat base from the wall.
Montando o novo termostato
- Separe a tampa frontal da base do termostato.
- Position the new thermostat base on the wall. Use the provided screws and anchors to secure it.
Fiação
Importante: Ensure power is off before wiring. This thermostat is for 2-wire heat-only systems. Connect wires only to R and W terminals.
Refer to the wiring diagram below. Identify each wire attached to the old thermostat by taking a photo of old wiring.

Image: Wiring diagram for the Emerson 1E78-140 thermostat. It illustrates connections for 2-wire heat-only systems to R and W terminals. The image also shows two AAA Energizer batteries and various mounting screws and anchors included with the thermostat. A caution notice regarding battery life and freeze hazard is visible.
- Connect the wire from your heating system's R terminal to the R terminal on the thermostat.
- Connect the wire from your heating system's W terminal to the W terminal on the thermostat.
Instalação da bateria
The thermostat requires two AAA batteries for operation. Install the batteries into the compartment located on the back of the thermostat, observing the correct polarity (+/-).

Imagem: Frente view of the Emerson 1E78-140 thermostat. The digital display shows "70" as the current temperature. To the right of the display are two gray buttons for adjusting the temperature up and down. Below the Emerson logo, a system switch is visible, set to "OFF HEAT".
After wiring and battery installation, attach the thermostat front cover to the base.
Turn on power to your heating system at the main fuse or circuit breaker panel.
Instruções de operação
Mudança de sistema
The system switch is located on the front of the thermostat. It has two positions:
- OFF: Turns the heating system off.
- AQUECER: Activates the heating system to maintain the set temperature.
Configurando a temperatura
Use the Up (▲) and Down (▼) buttons located next to the digital display to adjust your desired temperature setting. The thermostat will maintain this temperature with a precision of plus/minus 1 degree Fahrenheit.
Luz de fundo
The digital display features a backlight for improved visibility, especially in low-light conditions. The backlight activates when buttons are pressed.
Manutenção
Substituição da bateria
When the "Change Battery" indicator (a battery icon) is displayed on the screen, the batteries have limited remaining life and should be replaced soon. The system will not operate with dead batteries.
- Remova a tampa do termostato.
- Remova as pilhas AAA antigas.
- Insert two new AAA alkaline batteries, ensuring correct polarity.
- Substitua a tampa do termostato.
Limpeza
Limpe o termostato com um pano macio e seco.amp pano. Não use produtos de limpeza abrasivos ou solventes.
Solução de problemas
| Problema | Possível causa | Solução |
|---|---|---|
| A tela está em branco ou com brilho reduzido. | Baterias mortas ou fracas. | Substitua as duas pilhas AAA. |
| O sistema de aquecimento não liga. |
|
|
| "Change Battery" icon displayed. | Bateria fraca. | Replace the two AAA batteries promptly. |
Especificações
| Recurso | Detalhe |
|---|---|
| Marca | Emerson |
| Número do modelo | 1E78-140 |
| Tipo de controlador | Botão de pressão |
| Recurso especial | Exibição de temperatura |
| Tipo de controle de temperatura | Manual |
| Componentes incluídos | Thermostat, Temperature Sensor |
| Fonte de energia | Electric (2 AAA batteries for display/control) |
| Volumetage | 24 Volts (for system operation) |
| Tipo de exibição | LIDERADO |
| Método de controle | Toque (botões) |
| Tipo de montagem | Montagem na parede |
| Estilo | Digital |
| Luz de fundo | Sim |
| Compatibilidade | A maioria dos solteirostage heat-only systems (24V and millivolt). Not compatible with electric baseboard heat. |
| Precisão | +/- 1 degree F |

Imagem: Um lado view of the Emerson 1E78-140 thermostat, held in a hand for scale. The image indicates the thermostat's height is 5.5 inches (14 cm).
Informações de garantia
Specific warranty details for the Emerson 1E78-140 thermostat are typically provided with the product packaging or can be obtained directly from the manufacturer, Emerson. Please refer to the documentation included in your product box or visit the official Emerson webConsulte o site para obter os termos e condições de garantia mais recentes.
Suporte ao cliente
For technical assistance, troubleshooting beyond this manual, or inquiries regarding your Emerson 1E78-140 thermostat, please contact Emerson customer support. Contact information can usually be found on the product packaging or on the official Emerson website.