1. Introdução
This manual provides essential instructions for the installation, operation, and maintenance of your FSP iFP600 Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installing or operating the unit to ensure proper function and safety. The FSP iFP600 is designed to provide reliable power backup and surge protection for your electronic devices.

Imagem 1.1: Frente view of the FSP iFP600 UPS, showcasingraças ao seu design compacto e ao visor LCD integrado.
2. Instruções de segurança
Please adhere to these important safety guidelines during installation, operation, and maintenance of the UPS:
- Não abra a caixa da UPS.asing. Não existem peças que possam ser reparadas pelo usuário no interior. Encaminhe todos os serviços de manutenção para pessoal qualificado.
- Do not connect appliances that could overload the UPS, such as laser printers, vacuum cleaners, or heaters.
- Certifique-se de que o UPS esteja conectado a uma tomada CA aterrada.
- Evite colocar o UPS sob luz solar direta, perto de fontes de calor ou em ambientes com excesso de poeira, umidade ou substâncias corrosivas.
- Position the UPS in a well-ventilated area to prevent overheating.
- In case of fire, use a dry chemical extinguisher. Water can be hazardous.
- The battery inside the UPS is not user-replaceable. Battery replacement should only be performed by qualified personnel.
3. Produto acabadoview
The FSP iFP600 UPS provides reliable power protection for your critical electronics. It features a compact design and an intuitive LCD display for monitoring status.
3.1 Conteúdo da embalagem
Ao abrir a embalagem, verifique se todos os componentes estão presentes e sem danos:
- FSP iFP600 UPS Unit
- Manual do usuário (este documento)
- Cabo de alimentação
- Cabo de comunicação USB

Image 3.1: The FSP iFP600 UPS shown alongside its retail packaging, illustrating the product's presentation.
3.2 Componentes do painel traseiro
Familiarize yourself with the connections on the rear panel of the UPS:

Imagem 3.2: Detalhada view of the FSP iFP600 UPS rear panel, highlighting connection points.
- Pontos de venda: Two SCHUKO type outlets for connecting protected equipment.
- Entrada CA: Connects the UPS to the main utility power.
- Fuse/Breaker: Overcurrent protection for the UPS.
- Comunicação USB: Port for connecting to a computer for monitoring and management.
- Combo RJ11/RJ45 Surge Protection: Provides surge protection for telephone/network lines.
4. Configuração e instalação
Follow these steps to set up your FSP iFP600 UPS:
- Desembalagem: Retire cuidadosamente o UPS da embalagem. Inspecione-o para verificar se há danos causados pelo transporte.
- Colocação: Place the UPS on a flat, stable surface in a clean, cool, and well-ventilated area. Ensure adequate clearance around the unit for airflow.
- Carregamento inicial: Connect the UPS to a standard grounded AC outlet using the provided power cord. Allow the unit to charge for at least 4-6 hours before initial use to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
- Equipamento de conexão: Plug your computer, monitor, and other critical electronic devices into the UPS outlets (A). Do not connect surge suppressors or power strips to the UPS outlets.
- Comunicação USB (opcional): Connect the USB cable from the UPS USB port (D) to your computer's USB port to enable power management software features (software not included, typically downloaded from manufacturer's weblocal).
- RJ11/RJ45 Protection (Optional): For surge protection of your telephone or network line, connect the incoming line to the 'IN' port of the Combo RJ11/RJ45 (E) and connect the 'OUT' port to your device.
5. Instruções de operação
5.1 Ligar/Desligar
- Para ligar: Press and hold the power button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates.
- Para desligar: Press and hold the power button for approximately 2 seconds until you hear a beep and the LCD display turns off.
5.2 Informações do visor LCD
The FSP iFP600 features an LCD display that provides real-time status information. The display is touch-sensitive for navigating information.

Image 5.1: The LCD display of the FSP iFP600 UPS, indicating voltage output and its touch-screen functionality.
The LCD display typically shows:
- Vol de entradatage
- Volume de saídatage
- Nível de carga da bateria
- Nível de carga
- Operating Mode (e.g., AC mode, Battery mode)
- Warning/Fault Indicators
5.3 Battery Mode Operation
When the utility power fails or fluctuates outside acceptable limits, the UPS will automatically switch to battery mode. During battery mode, the UPS will provide power to connected equipment from its internal battery. An audible alarm will sound to indicate battery operation.
6. Manutenção
Proper maintenance ensures the longevity and reliability of your UPS.
- Limpeza: Use a soft, dry cloth to clean the exterior of the UPS. Do not use liquid or aerosol cleaners.
- Cuidados com a bateria: To maximize battery life, ensure the UPS is connected to AC power and fully charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.
- Substituição da bateria: The internal battery (12V / 7Ah x1) is not user-serviceable. Battery replacement should only be performed by FSP-certified service personnel or a qualified technician. Incorrect battery replacement can pose a risk of explosion or injury.
- Armazenar: Store the UPS in a cool, dry place with adequate ventilation. Ensure the battery is fully charged before storage.
7. Solução De Problemas
Refer to the following table for common issues and their solutions. If the problem persists, contact FSP support.
| Sintoma | Alarme sonoro | Possível causa | Solução |
|---|---|---|---|
| UPS operating on battery power | Bips a cada 10 segundos | Utility power failure or fluctuation | Save work and shut down equipment if power outage is prolonged. UPS will return to AC mode when power is restored. |
| Aviso de bateria fraca | Bipa a cada segundo | A carga da bateria está criticamente baixa | Immediately save work and shut down connected equipment. |
| Condição de sobrecarga | Bipa a cada 0.5 segundo | O número de equipamentos conectados excede a capacidade do UPS. | Disconnect non-essential equipment until the alarm stops. Ensure total load is within UPS capacity. |
| Falha no UPS | Bipando continuamente | Falha interna ou mau funcionamento | Turn off the UPS and disconnect it from the AC outlet. Contact FSP technical support. |

Image 7.1: Excerpt from the FSP iFP series specification table, detailing alarm indicators and their meanings.
8. Especificações
Detailed technical specifications for the FSP iFP600 UPS:
| Recurso | Especificação |
|---|---|
| Modelo | iFP 600 |
| Capacidade | 600 VA / 360 W |
| Vol de entradatage | 110/120 Vac or 220/230/240 Vac |
| Vol de entradatage Alcance | 81-145 Vca / 140-290 Vca |
| Faixa de frequência de entrada | 60/50 Hz (detecção automática) |
| Volume de saídatage | 110/120 Vac or 220/230/240 Vac |
| Vol. CAtage Regulação (modo de bateria) | ±10% |
| Output Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Tempo de transferência | 2-6 ms típicos |
| Forma de onda (modo Batt.) | Onda senoidal simulada |
| Tipo e número da bateria | 12V / 7Ah x1 |
| Tempo de recarga típico | 4 horas até 90% da capacidade |
| Indicadores | LCD Display (Touch panel with digital information) |
| Proteção | Overload, Discharge, and Overcharge Protection |
| Peso do item | 9.24 libras (4.2 kg) |
| Dimensões do produto (CxLxA) | 11.81 x 3.98 x 5.59 polegadas |
| Cor | Preto |
| Material | Metal |
9. Garantia e Suporte
FSP products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official FSP website. For technical support, troubleshooting assistance, or service inquiries, please contact FSP customer service through their official channels.
Você pode encontrar mais informações e recursos de suporte em FSP Store on Amazon.