1. Introdução

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Truper 13499 PRES-1/3T 1/3 HP Pressure Booster Pump. Please read these instructions carefully before installation and use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Informações de segurança

Observe sempre as seguintes precauções de segurança:

3. Componentes do produto

The Truper 13499 PRES-1/3T Pressure Booster Pump includes the main pump unit, an integrated pressure switch, and power cord with an on/off switch. Refer to the image below for a visual representation of the pump and its key components.

Truper 13499 PRES-1/3T Pressure Booster Pump

Figura 1: Truper 13499 PRES-1/3T Pressure Booster Pump. This image shows the complete pump assembly, including the orange motor housing, the dark gray pump body, brass fittings for water inlet and outlet, and the integrated flow switch with an arrow indicating water flow direction. The power cord with an inline on/off switch is also visible.

Componentes chave:

4. Configuração e instalação

A instalação correta é crucial para o desempenho e a vida útil da bomba.

  1. Localização:
    • Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures.
    • Certifique-se de que a bomba esteja colocada em uma superfície estável e nivelada para minimizar a vibração.
    • Allow adequate space around the pump for ventilation and maintenance access.
  2. Conexões de encanamento:
    • Connect the pump to the water supply line using appropriate plumbing fittings. Ensure all connections are watertight.
    • Observe the flow direction indicated by the arrow on the flow switch (Figure 1). The pump must be installed in line with the water flow.
    • Use flexible connectors to reduce vibration transmission to the plumbing system.
    • Install shut-off valves on both the inlet and outlet sides of the pump for easier maintenance.
  3. Conexão elétrica:
    • Ensure the power outlet is properly grounded and matches the pump's electrical requirements (127 V - 60 Hz).
    • Plug the pump's power cord into the grounded outlet.
    • Do not use extension cords unless absolutely necessary, and ensure they are rated for the pump's power requirements.
  4. Preparando a bomba:
    • Before initial operation, ensure the pump is filled with water to prevent dry running. Open a faucet downstream to allow air to escape.
    • Once water flows steadily from the faucet, close it. The pump is now primed.

5. Instruções de operação

The Truper 13499 PRES-1/3T pump operates automatically based on water flow.

  1. Inicialização inicial:
    • After installation and priming, ensure the inline switch on the power cord is in the "OFF" position.
    • Conecte a bomba a uma tomada elétrica adequada.
    • Switch the inline power switch to the "ON" position. The pump will remain off until water flow is detected.
  2. Operação automática:
    • When a water outlet (e.g., faucet, shower) is opened, the flow switch detects water movement.
    • The pump automatically starts, boosting water pressure.
    • When the water outlet is closed, the flow stops, and the pump automatically shuts off after a short delay.
  3. Ciclo de trabalho:
    • The pump is designed for intermittent use: 50 minutes of work followed by 20 minutes of rest.
    • The daily maximum operating time is 6 hours. Adhering to this duty cycle will prolong the pump's lifespan.

6. Manutenção

A manutenção regular garante o desempenho ideal e prolonga a vida útil da sua bomba.

Warning: Always disconnect the pump from the power supply before performing any maintenance.

7. Solução De Problemas

This section addresses common issues you might encounter with your pressure booster pump.

ProblemaPossível causaSolução
A bomba não arranca.Sem fonte de alimentação.
Inline switch is OFF.
No water flow detected.
Verifique a tomada e o disjuntor.
Turn inline switch to ON.
Open a water outlet to initiate flow. Ensure pump is primed.
A bomba funciona continuamente.Leak in plumbing system.
Flow switch malfunction.
Constant low water flow.
Check all connections for leaks and repair.
Entre em contato com pessoal de serviço qualificado.
Ensure all outlets are fully closed.
Insufficient pressure boost.Bomba mal escorvada.
Inlet water pressure too low.
Obstruction in plumbing.
Volte a preparar a bomba.
Ensure minimum input pressure of 0.72 PSI is met.
Inspect plumbing for blockages.
A bomba é ruidosa ou vibra excessivamente.Ar no sistema.
Montagem frouxa.
Internal component wear.
Re-prime the pump to remove air.
Ensure pump is securely mounted on a stable surface.
Entre em contato com pessoal de serviço qualificado.

8. Especificações técnicas

RecursoEspecificação
Modelo13499 / PRES-1/3T
Poder1/3 HP (248 W)
Volumetage - Frequency127 V - 60 Hz
Fluxo Máximo15 gal/min (27 L/min) / 60 Liters Per Minute
Minimum Input Pressure0.72 PSI
Pressão Máxima17 PSI
Ciclo de trabalho50 min. work per 20 min. rest
Daily Maximum Operation6 horas
MaterialAlumínio casing
Peso9 lb (4.3 Kg) / 10.36 pounds (shipping)
Dimensions (B x H x W)5 1/8" x 11 13/16" x 6 5/16" (13 x 30 x 16 cm) / 7.09 x 5.91 x 5.91 inches (product)
Water Outlets SupportedAté 3 simultâneos
Tipo de operaçãoOn demand (Autostop switch)

9. Garantia e Suporte

For warranty information or technical support, please refer to the documentation included with your purchase or contact Truper customer service. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official Truper webou entre em contato com os centros de serviço autorizados.

Documentos relacionados - 13499

Préview Manual da Bomba de Pressurização de Água Truper PRES-1
Manual completo da bomba pressurizadora de água Truper PRES-1, abrangendo especificações técnicas, avisos de segurança, instalação, operação, manutenção e solução de problemas.
Préview Manual do Usuário da Bomba de Pressurização de Água Ajustável TRUPER PRE-1/3
Manual do usuário completo para a bomba pressurizadora de água ajustável TRUPER PRE-1/3. Inclui especificações técnicas, instruções de segurança, guia de instalação, procedimentos de manutenção, dicas de solução de problemas e informações sobre a garantia.
Préview TRUPER PRE-1/6 Water Pressure Booster Pump Manual
Official instruction manual for the TRUPER PRE-1/6 Water Pressure Booster Pump. Includes technical specifications, safety warnings, installation guide, maintenance, troubleshooting, and warranty information.
Préview TRUPER PRE-1/6R Water Pressure Booster Pump User Manual
Comprehensive user manual for the TRUPER PRE-1/6R water pressure booster pump, covering technical specifications, safety warnings, installation guide, operating instructions, maintenance procedures, and troubleshooting tips.
Préview Manual do Sistema de Aumento de Pressão Hidropneumático TRUPER - HIDR-1/2X24, HIDR-1/2X50
Comprehensive user manual for the TRUPER Hydropneumatic Pressure Boosting System (Models HIDR-1/2X24, HIDR-1/2X50), covering technical data, power requirements, safety warnings, parts identification, installation guide, pressure switch operation, start-up procedures, maintenance, troubleshooting, authorized service centers, and warranty policy.
Préview TRUPER Adjustable Water Pressure Booster Pump PRE-1/6R User Manual
Comprehensive user manual for the TRUPER Adjustable Water Pressure Booster Pump, Model PRE-1/6R. Includes technical specifications, installation instructions, safety warnings, maintenance, and troubleshooting.