1. Introdução
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Truper 13499 PRES-1/3T 1/3 HP Pressure Booster Pump. Please read these instructions carefully before installation and use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.
2. Informações de segurança
Observe sempre as seguintes precauções de segurança:
- Certifique-se de que a fonte de alimentação seja compatível com a voltagem da bomba.tage and frequency (127 V - 60 Hz).
- Desligue a energia antes de realizar qualquer manutenção ou instalação.
- Não utilize a bomba com líquidos inflamáveis.
- Proteja a bomba de temperaturas de congelamento.
- Installation should be performed by a qualified professional if you are unsure.
- Mantenha crianças e pessoas não autorizadas longe da bomba em funcionamento.
3. Componentes do produto
The Truper 13499 PRES-1/3T Pressure Booster Pump includes the main pump unit, an integrated pressure switch, and power cord with an on/off switch. Refer to the image below for a visual representation of the pump and its key components.

Figura 1: Truper 13499 PRES-1/3T Pressure Booster Pump. This image shows the complete pump assembly, including the orange motor housing, the dark gray pump body, brass fittings for water inlet and outlet, and the integrated flow switch with an arrow indicating water flow direction. The power cord with an inline on/off switch is also visible.
Componentes chave:
- Corpo da bomba: Dark gray cast iron housing for the impeller and water channels.
- Carcaça do motor: Orange casing protecting the electric motor.
- Inlet/Outlet Fittings: Brass threaded connections for plumbing.
- Chave de fluxo: Orange component with an arrow, detecting water flow to activate the pump.
- Cabo de alimentação: Electrical connection with an integrated on/off switch.
4. Configuração e instalação
A instalação correta é crucial para o desempenho e a vida útil da bomba.
- Localização:
- Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures.
- Certifique-se de que a bomba esteja colocada em uma superfície estável e nivelada para minimizar a vibração.
- Allow adequate space around the pump for ventilation and maintenance access.
- Conexões de encanamento:
- Connect the pump to the water supply line using appropriate plumbing fittings. Ensure all connections are watertight.
- Observe the flow direction indicated by the arrow on the flow switch (Figure 1). The pump must be installed in line with the water flow.
- Use flexible connectors to reduce vibration transmission to the plumbing system.
- Install shut-off valves on both the inlet and outlet sides of the pump for easier maintenance.
- Conexão elétrica:
- Ensure the power outlet is properly grounded and matches the pump's electrical requirements (127 V - 60 Hz).
- Plug the pump's power cord into the grounded outlet.
- Do not use extension cords unless absolutely necessary, and ensure they are rated for the pump's power requirements.
- Preparando a bomba:
- Before initial operation, ensure the pump is filled with water to prevent dry running. Open a faucet downstream to allow air to escape.
- Once water flows steadily from the faucet, close it. The pump is now primed.
5. Instruções de operação
The Truper 13499 PRES-1/3T pump operates automatically based on water flow.
- Inicialização inicial:
- After installation and priming, ensure the inline switch on the power cord is in the "OFF" position.
- Conecte a bomba a uma tomada elétrica adequada.
- Switch the inline power switch to the "ON" position. The pump will remain off until water flow is detected.
- Operação automática:
- When a water outlet (e.g., faucet, shower) is opened, the flow switch detects water movement.
- The pump automatically starts, boosting water pressure.
- When the water outlet is closed, the flow stops, and the pump automatically shuts off after a short delay.
- Ciclo de trabalho:
- The pump is designed for intermittent use: 50 minutes of work followed by 20 minutes of rest.
- The daily maximum operating time is 6 hours. Adhering to this duty cycle will prolong the pump's lifespan.
6. Manutenção
A manutenção regular garante o desempenho ideal e prolonga a vida útil da sua bomba.
- Limpeza: Periodically clean the exterior of the pump to prevent dust and debris buildup. Do not use harsh chemicals.
- Conexões: Regularly check all plumbing and electrical connections for leaks or loose fittings. Tighten as necessary.
- Winterização: If the pump is installed in an area subject to freezing temperatures, it must be drained and disconnected during winter months to prevent damage.
- Inspeção: Inspecione o cabo de alimentação em busca de sinais de danos ou desgaste. Substitua se necessário.
Warning: Always disconnect the pump from the power supply before performing any maintenance.
7. Solução De Problemas
This section addresses common issues you might encounter with your pressure booster pump.
| Problema | Possível causa | Solução |
|---|---|---|
| A bomba não arranca. | Sem fonte de alimentação. Inline switch is OFF. No water flow detected. | Verifique a tomada e o disjuntor. Turn inline switch to ON. Open a water outlet to initiate flow. Ensure pump is primed. |
| A bomba funciona continuamente. | Leak in plumbing system. Flow switch malfunction. Constant low water flow. | Check all connections for leaks and repair. Entre em contato com pessoal de serviço qualificado. Ensure all outlets are fully closed. |
| Insufficient pressure boost. | Bomba mal escorvada. Inlet water pressure too low. Obstruction in plumbing. | Volte a preparar a bomba. Ensure minimum input pressure of 0.72 PSI is met. Inspect plumbing for blockages. |
| A bomba é ruidosa ou vibra excessivamente. | Ar no sistema. Montagem frouxa. Internal component wear. | Re-prime the pump to remove air. Ensure pump is securely mounted on a stable surface. Entre em contato com pessoal de serviço qualificado. |
8. Especificações técnicas
| Recurso | Especificação |
|---|---|
| Modelo | 13499 / PRES-1/3T |
| Poder | 1/3 HP (248 W) |
| Volumetage - Frequency | 127 V - 60 Hz |
| Fluxo Máximo | 15 gal/min (27 L/min) / 60 Liters Per Minute |
| Minimum Input Pressure | 0.72 PSI |
| Pressão Máxima | 17 PSI |
| Ciclo de trabalho | 50 min. work per 20 min. rest |
| Daily Maximum Operation | 6 horas |
| Material | Alumínio casing |
| Peso | 9 lb (4.3 Kg) / 10.36 pounds (shipping) |
| Dimensions (B x H x W) | 5 1/8" x 11 13/16" x 6 5/16" (13 x 30 x 16 cm) / 7.09 x 5.91 x 5.91 inches (product) |
| Water Outlets Supported | Até 3 simultâneos |
| Tipo de operação | On demand (Autostop switch) |
9. Garantia e Suporte
For warranty information or technical support, please refer to the documentation included with your purchase or contact Truper customer service. Keep your purchase receipt as proof of purchase.
For further assistance, visit the official Truper webou entre em contato com os centros de serviço autorizados.