APOLLO 69ELF114TWG

Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge Instruction Manual

Model: 69ELF114TWG

1. Produto acabadoview

The Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge (Model 69ELF114TWG) is designed to reduce incoming water pressure to a safe and consistent level for residential and commercial plumbing systems. This unit features a compact design, lead-free bronze construction, and an integrated internal bypass mechanism. It includes a color-coded gauge for easy pressure monitoring and adjustment.

Apollo 3/4 inch Bronze Water Pressure Regulator with Gauge

Figure 1: Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge. This image shows the regulator with its integrated pressure gauge and yellow adjustment handle.

2. Informações de segurança

3. Conteúdo da embalagem

Verifique se todos os componentes estão presentes antes de iniciar a instalação:

4. Instalação

This regulator features a double union PEX-A (cold expansion) barb design for simplified installation in PEX-A piping systems. Ensure the regulator is installed in the correct flow direction, indicated by an arrow on the body.

  1. Prepare o local de instalação: Turn off the main water supply. Drain the water lines to relieve pressure. Select a suitable location for the regulator, typically after the main shut-off valve and before any branch lines.
  2. Cut and Prepare PEX-A Piping: Cut the PEX-A pipe to the required length, ensuring clean, square cuts. Prepare the pipe ends for cold expansion connections according to PEX-A system manufacturer guidelines.
  3. Conecte o regulador:
    • Apply appropriate thread sealant (e.g., Teflon tape or pipe dope) to the male threads of the PEX-A fittings.
    • Thread the PEX-A fittings onto the double union ends of the regulator. Ensure the flow arrow on the regulator body points in the direction of water flow into the building.
    • Tighten the union nuts securely, but do not overtighten.
    • Perform cold expansion connections on the PEX-A pipe ends to the fittings according to PEX-A system manufacturer instructions.
  4. Instale o manômetro: The pressure gauge is typically pre-installed. Ensure it is securely threaded into the designated port on the regulator body.
  5. Restore Water Supply and Check for Leaks: Slowly turn on the main water supply. Carefully inspect all connections for any signs of leaks. Tighten connections as necessary.
Apollo Water Pressure Regulator with PEX-A connections

Figura 2: Lateral view of the Apollo Water Pressure Regulator, showing the double union PEX-A connections and the flow direction arrow. Note the "MAX INLET 400 PSI" marking.

5. Instruções de operação

The regulator is factory-set at 50 psi and is adjustable from 15 psi to 75 psi. No special tools are required for adjustment.

  1. Verifique a pressão atual: Observe the reading on the integrated pressure gauge. The gauge is color-coded to indicate pressure ranges (e.g., Low, Optimal, Excessive).
  2. Ajustando a pressão:
    • Para aumentar pressure: Turn the yellow adjustment handle sentido horário.
    • Para diminuir pressure: Turn the yellow adjustment handle sentido anti-horário.
    • Make small adjustments and allow the system pressure to stabilize before re-checking the gauge.
  3. Confirmar configuração: Once the desired pressure is achieved (typically between 50-60 psi for most residential applications), confirm the reading on the gauge.
Apollo Water Pressure Regulator with gauge showing optimal pressure range

Figura 3: Close view of the Apollo Water Pressure Regulator, highlighting the pressure gauge with its color-coded optimal range and the yellow adjustment handle.

6. Manutenção

The Apollo Water Pressure Regulator is designed for minimal maintenance. Regular checks can help ensure optimal performance.

7. Solução De Problemas

ProblemaPossível causaSolução
No water flow or very low pressure downstreamRegulator set too low; Main water supply off; Regulator clogged.Increase pressure setting; Check main water valve; Inspect for debris (consult a plumber if necessary).
Pressure too high downstreamRegulator set too high; Regulator malfunction.Decrease pressure setting; If problem persists, regulator may need replacement.
Water hammer or fluctuating pressureRapid changes in water demand; Regulator bypass mechanism issue.Ensure proper air chambers are installed in the plumbing system; Consult a plumber for regulator inspection.
Vazamentos nas conexõesImproperly tightened connections; Insufficient thread sealant.Tighten connections; Reapply thread sealant if necessary (ensure water supply is off first).

8. Especificações

9. Garantia e Suporte

This Apollo Water Pressure Regulator comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact Apollo customer support.

For technical support or inquiries, please visit the official Apollo website ou entre em contato com o departamento de atendimento ao cliente.